40 resultados para EUSTACHIAN TUBE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine, in dogs anesthetized with nitrous oxide (N2O), whether the endotracheal tube (ETT) cuffed with a Lanz® pressure regulating valve decreases the tracheal consequences of tracheal intubation. Methods: Sixteen mixed-breed dogs were allocated to two groups according to the ETT used: Control group (n = 8) - Rüsch ETT, and Lanz group (n = 8) - ETT with Lanz® pressure regulating valve. The ETT cuffs in both groups were inflated with air to an intracuff pressure of 30 cm H2O. Anesthesia was induced and maintained with pentobarbitone and N2O (1.5 L·min-1) and O2 (1 L·min-1). ETT cuff pressures were measured before (control) and 60, 120, and 180 min during N2O administration. The dogs were sacrificed, and biopsy specimens from four predetermined areas of the tracheal mucosa in contact with the ETT were collected for light and scanning electron microscopy (SM) examination. Results: Cuff pressures in the Control group were higher than in the Lanz group at all time points studied (P < 0.001), with an increase over time only in the Control group (P < 0.001). Median neutrophilic inflammatory infiltration values of the epithelial surface, and in the subepithelial layer in contact with the cuff, were higher in the Control group as compared to the Lanz group (3.0 vs 1.0 and 3.0 vs 1.5 respectively) (P < 0.05). On SM examination, median histological grades were higher in the Control group compared to Lanz group (2.9 vs 1.9 respectively), (P < 0.05). Conclusions: The Lanz® ETT decreases tracheal mucosal injury in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)