38 resultados para Cyclic steam stimulation
Resumo:
There are few electrophysiologic studies in wild animals. The aim of this study was to determine normal data for motor nerve conduction studies and repetitive stimulation in sciatic-tibial and ulnar nerves in clinically normal captive coati. Eight adult ring-tailed coatis (Nasua nasua), two females and six males weighing 68 kg, were used. Average nerve conduction velocity was 70.81 m/sec (standard deviation [SD] = 3.98) and 56.93 m/sec (SD = 4.31) for the sciatic-tibial and ulnar nerves, respectively. Repetitive stimulation responses demonstrated minimal variations of the area of the compound muscle action potentials at low (3 Hz) and high (20 Hz) frequencies. The maximal obtained decremental area response was 8%. These normal data of conduction studies may be used in assessing abnormalities for clinical diagnosis. In addition, the obtained normal repetitive stimulation data were similar to dogs and humans and may be used for post- and presynaptic disturbances of the neuromuscular transmission in coatis.
Resumo:
The aim of this study was to evaluate the effect of intravaginal electrical stimulation (IES) on pelvic floor muscle (PFM) strength in patients with mixed urinary incontinence (MUI). Between January 2001 and February 2002, 40 MUI women (mean age: 48 years) were studied. Urge incontinence was the predominant symptom; 92.5% also presented mild stress urinary incontinence (SUI). Selection criteria were clinical history and urodynamics. Pre-treatment urodynamic study showed no statistical differences between the groups. Ten percent of the women in each group had involuntary detrusor contractions. Patients were randomly distributed, in a double-blind study, into two groups. Group G 1 (n=20), effective IES, and group G2 (n=20), sham IES, with follow-up at 1 month. The following parameters were studied: (1) clinical questionnaire, (2) examiner's evaluation of perineal muscle strength, (3) objective evaluation of perineal muscle by perineometry, (4) vaginal weight test, and (5) urodynamic study. The IES protocol consisted of three 20-min sessions per week over a 7-week period using a Dualpex Uro 996 at 4 Hz. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence, present in all patients before treatment, was reduced to 15% in G1 and 31.5% in G2 post-treatment. The subjective evaluation of PFM strength demonstrated a significant improvement in G1. Objective evaluation of PFM force by perineometer showed a significant improvement in maximum peak contraction post-treatment in both groups. In the vaginal weight test, there was a significant increase in average number of cone retentions post-treatment in both groups. With regard to satisfaction level, after treatment, 80% of the patients in G1 and 65% of the patients in G2 were satisfied. There was no statistically significant difference between the groups. There was a significant improvement in PFM strength from both effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy in treating MUI.
Resumo:
Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.
Electroacupuncture analgesia in dogs: is there a difference between uni- and bi-lateral stimulation?
Resumo:
Objective To compare the analgesic effect of uni- and bi-lateral electroacupuncture (EA) in response to thermal and mechanical nociceptive stimuli and to investigate the cardiorespiratory, endocrine, and behavioral changes in dogs submitted to EA.Study design Prospective, randomized cross-over experimental study.Animals Eight adult, clinically healthy, cross-breed dogs, weighing 13 +/- 4 kg.Methods Dogs underwent electrostimulation at false acupoints (T-false); bilateral EA at acupoints, stomach 36, gall bladder 34 and spleen 6 (T-EA/bil); unilateral EA at the same points (T-EA/uni) or were untreated (T-control). All animals received acepromazine (0.05 mg kg(-1)) IV; and heart rate, pulse oximetry, indirect arterial blood pressure, respiratory rate, PECO2, rectal temperature, and plasma cortisol concentration were measured before, during, and after EA. Analgesia was tested using thoracic and abdominal cutaneous thermal and mechanical stimuli, and an interdigital thermal stimulus. Behavior was classified as calm or restless. Analysis of variance for repeated measures followed by Tukey's test was used for analysis of the data.Results There were no cardiorespiratory differences among the treatments. The cutaneous pain threshold was higher after EA, compared with false points. The latency period was shorter and analgesia was more intense in T-EA/bil than T-EA/uni, when both were compared with T-false and T-control. Six out of eight animals treated with EA were calm during treatment, and 5/8 and 4/8 of the T-false and T-control animals, respectively, were restless. Latency to interdigital thermal stimulation increased in T-EA/bil compared with the others. There was no difference in plasma cortisol concentrations among the treatments.Conclusions Bilateral EA produced a shorter latency period, a greater intensity, and longer duration of analgesia than unilateral stimulation, without stimulating a stress response.Clinical relevance Bilateral EA produces a better analgesic effect than unilateral EA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This in situ/ex vivo study evaluated whether saliva stimulated by chewing gum could prevent or reduce the wear and the percent change in microhardness (%SMH) of bovine and human enamel submitted to erosion followed by brushing abrasion immediately or after 1 h. During 2 experimental 7-day crossover phases, 9 previously selected volunteers wore intraoral palatal devices, with 12 enamel specimens (6 human and 6 bovine). In the first phase, the volunteers immersed the device for 5 min in 150 ml of cola drink, 4 times per day (at 8, 12, 16 and 20 h). Immediately after the immersions, no treatment was performed in 4 specimens, 4 other specimens were immediately brushed (0 min) using a fluoride dentifrice, and the device was replaced into the mouth. After 60 min, the remaining 4 specimens were brushed. In the second phase, the procedures were repeated, but after the immersions, the volunteers stimulated the salivary flow rate by chewing a sugar-free gum for 30 min. Changes in wear and %SMH were measured. ANOVA and Tukey's test showed statistical differences (p < 0.05) for the following comparisons. The chewing gum promoted less wear and %SMH. A decreasing %SMH and an increasing enamel wear were observed in the following conditions: erosion only, 60 min and 0 min. The human enamel presented greater %SMH and less wear compared to bovine enamel. The data suggest that the salivary stimulation after an erosive or erosive/abrasive attack can reduce the dental wear and the %SMH.
Resumo:
Background and Objectives: Bone remodeling is characterized as a cyclic and lengthy process. It is currently accepted that not only this dynamics is triggered by a biological process, but also biochemical, electrical, and mechanical stimuli are key factors for the maintenance of bone tissue. The hypothesis that low-level laser therapy (LLLT) may favor bone repair has been suggested. The purpose of this study was to evaluate the bone repair in defects created in rat lower jaws after stimulation with infrared LLLT directly on the injured tissue.Study Design/Materials and Methods: Bone defects were prepared on the mandibles of 30 Holtzman rats allocated in two groups (n = 15), which were divided in three evaluation period (15, 45, and 60 days), with five animals each. control group-no treatment of the defect; laser group-single laser irradiation with a GaAlAs semiconductor diode laser device (lambda = 780 nm; P = 35 mW t = 40 s; circle minus = 1.0 mm; D = 178 J/cm(2); E = 1.4 J) directly on the defect area. The rats were sacrificed at the preestablished periods and the mandibles were removed and processed for staining with hematoxylin and eosin, Masson's Trichrome and picrosirius techniques.Results: the histological results showed bone formation in both groups. However, the laser group exhibited an advanced tissue response compared to the control group, abbreviating the initial inflammatory reaction and promoting rapid new bone matrix formation at 15 and 45 days (P < 0. 05). on the other hand, there were no significant differences between the groups at 60 days.Conclusion: the use of infrared LLLT directly to the injured tissue showed a biostimulating effect on bone remodeling by stimulating the modulation of the initial inflammatory response and anticipating the resolution to normal conditions at the earlier periods. However, there were no differences between the groups at 60 days.