85 resultados para Computerized tomography
Resumo:
The study of the nervous system is increasing in Veterinary Medicine. Transcranial ultrasonography (TCUS) has the advantage of being a non-invasive and low cost method compared to computerized tomography (CT) and Magnetic Resonance Imaging (MRI). The temporal bone has been used as an acoustic window in TCUS in humans. This study aimed to correlate transcranial ultrasonographic images obtained through the temporal and occipital window with healthy dog's encephalic anatomy, and to standardize the technique. 37 adult mongrel dogs were used: 30 animals in vivo, in order to perform USTC screening and seven dog corpses for brain section as well as USTC planes. Data analysis was accomplished by the non parametric Wilcoxon test. Results obtained indicate that TCUS (in dorsal and oblique planes) is a viable method for brain evaluation in dogs weighting up to 10kg without anesthesia.
Resumo:
Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results: The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.
Resumo:
New strategies to fulfill craniofacial bone defects have gained attention in recent years due to the morbidity of autologous bone graft harvesting. We aimed to evaluate the in vivo efficacy of bone tissue engineering strategy using mesenchymal stem cells associated with two matrices (bovine bone mineral and α-tricalcium phosphate), compared to an autologous bone transfer. A total of 28 adult, male, non-immunosuppressed Wistar rats underwent a critical-sized osseous defect of 5 mm diameter in the alveolar region. Animals were divided into five groups. Group 1 (n = 7) defects were repaired with autogenous bone grafts; Group 2 (n = 5) defects were repaired with bovine bone mineral free of cells; Group 3 (n = 5) defects were repaired with bovine bone mineral loaded with mesenchymal stem cells; Group 4 (n = 5) defects were repaired with α-tricalcium phosphate free of cells; and Group 5 (n = 6) defects were repaired with α-tricalcium phosphate loaded with mesenchymal stem cells. Groups 2-5 were compared to Group 1, the reference group. Healing response was evaluated by histomorphometry and computerized tomography. Histomorphometrically, Group 1 showed 60.27% ± 16.13% of bone in the defect. Groups 2 and 3 showed 23.02% ± 8.6% (p = 0.01) and 38.35% ± 19.59% (p = 0.06) of bone in the defect, respectively. Groups 4 and 5 showed 51.48% ± 11.7% (p = 0.30) and 61.80% ± 2.14% (p = 0.88) of bone in the defect, respectively. Animals whose bone defects were repaired with α-tricalcium phosphate and mesenchymal stem cells presented the highest bone volume filling the defects; both were not statistically different from autogenous bone.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The force delivered during rapid maxillary expansion (RME) produces areas of compression on the periodontal ligament of the supporting teeth. The resulting alveolar bone resorption can lead to unwanted tooth movement in the same direction. The purpose of this study was to evaluate periodontal changes by means of computed tomography after RME with tooth-tissue-borne and tooth-borne expanders. Methods: The sample comprised 8 girls, 11 to 14 years old, with Class I or II malocclusions with unilateral or bilateral posterior crossbites Four girls were treated with tooth-tissue-borne Haas-type expanders, and 4 were treated with tooth-borne Hyrax expanders. The appliances were activated up to the full 7-mm capacity of the expansion screw. Spiral CT scans were taken before expansion and after the 3-month retention period when the expander was removed. One-millimeter thick axial sections were exposed parallel to the palatal plane, comprising the dentoalveolar area and the base of the maxilla up to the inferior third of the nasal cavity. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal alveolar bone crest level by means of the computerized method. Results and Conclusions: RME reduced the buccal bone plate thickness of supporting teeth 0.6 to 0.9 mm and increased the lingual bone plate thickness 0.8 to 1.3 mm. The increase in lingual bone plate thickness of the maxillary posterior teeth was greater in the tooth-borne expansion group than in the tooth-tissue-borne group. RME induced bone dehiscences on the anchorage teeth's buccal aspect (7.1 ± 4.6 mm at the first premolars and 3.8 ± 4.4 mm at the mesiobuccal area of the first molars), especially in subjects with thinner buccal bone plates. The tooth-borne expander produced greater reduction of first premolar buccal alveolar bone crest level than did the tooth-tissue-borne expander. © 2006 American Association of Orthodontists.
Resumo:
This paper proposes a different experimental setup compared with the traditional ones, in order to determine the acceleration of gravity, which is carried out by using a fluid at a constant rotation. A computerized rotational system-by using a data acquisition system with specific software, a power amplifier and a rotary motion sensor-is employed in order to evaluate the angular velocity and g. An equation to determine g is inferred from fluid mechanics. For this purpose, the fluid's parabolic shape inside a cylindrical receptacle is considered using a rotational movement.
Resumo:
Computerized technological resources have become essential in education, particularly for teaching topics that require the performance of specific tasks. These resources can effectively help the execution of such tasks and the teaching-learning process itself. After the development of a Web site on the topic of nursing staff scheduling, this study aimed at comparing the development of students involved in the teaching-learning process of the previously mentioned topic, with and without the use of computer technology. Two random groups of undergraduate nursing students from a public university in São Paulo state, Brazil, were organized: a case group (used the Web site) and a control group (did not use the Web site). Data were collected from 2003 to 2005 after approval by the Research Ethics Committee. Results showed no significant difference in motivation or knowledge acquisition. A similar performance for the two groups was also verified. Other aspects observed were difficulty in doing the nursing staff scheduling exercise and the students' acknowledgment of the topic's importance for their training and professional lives; easy access was considered to be a positive aspect for maintaining the Web site.
Resumo:
OBJETIVOS: propor padrão de normalidade das dimensões do IVventrículo e estudar suas características em neurocisticercose. MÉTODO: em um grupo controle (GC) constituído de 114 indivíduos com tomografias normais e em outro grupo composto de 80 doentes com neurocisticercose (GN), mediram-se a distância fronto-polar de ventrículos laterais (FP) e os diâmetros craniano interno (Cr), ântero-posterior (AP) e látero-lateral (LL) do IVº ventrículo para a padronização de seis índices. RESULTADOS: AP/Cr, AP/LL e AP/FP foram os índices mais discriminatórios e apresentaram, em GC, valores médios de 0,063, 0,267 e 0,582, respectivamente. em GN os valores foram estatisticamente superiores a GC. Selecionaram-se 51 doentes do GN com índice> ou =2 desvios-padrão da média em GC. Neles, AP/Ll foi> ou =1 em 95% doentes com derivação liquórica e em 88% com depressão, ocorrendo em 73% com evolução satisfatória e todos que faleceram. CONCLUSÃO: AP/Cr, AP/LL e, principalmente, AP/FP são representativos das dimensões do IVventrículo.
Resumo:
In the present experimental study we assessed induced osteoarthritis data in rabbits, compared three diagnostic methods, i.e., radiography (XR), computed tomography (CT) and magnetic resonance imaging (MRI), and correlated the imaging findings with those obtained by macroscopic evaluation. Ten young female rabbits of the Norfolk breed were used. Seven rabbits had the right knee immobilized in extension for a period of 12 weeks (immobilized group), and three others did not have a limb immobilized and were maintained under the same conditions (control group). Alterations observed by XR, CT and MRI after the period of immobilization were osteophytes, osteochondral lesions, increase and decrease of joint space, all of them present both in the immobilized and non-immobilized contralateral limbs. However, a significantly higher score was obtained for the immobilized limbs (XT: P = 0.016, CT: P = 0.031, MRI: P = 0.0156). All imaging methods were able to detect osteoarthritis changes after the 12 weeks of immobilization. Macroscopic evaluation identified increased thickening of joint capsule, proliferative and connective tissue in the femoropatellar joint, and irregularities of articular cartilage, especially in immobilized knees. The differences among XR, CT and MRI were not statistically significant for the immobilized knees. However, MRI using a 0.5 Tesla scanner was statistically different from CT and XR for the non-immobilized contralateral knees. We conclude that the three methods detected osteoarthritis lesions in rabbit knees, but MRI was less sensitive than XR and CT in detecting lesions compatible with initial osteoarthritis. Since none of the techniques revealed all the lesions, it is important to use all methods to establish an accurate diagnosis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The mature dentinoenamel junction (DEJ) is viewed by some investigators and the current authors, not as a fossilized, sharp transition between enamel and dentin, but as a relatively broad structural transition zone including the mantle dentin and the inner aprismatic enamel. In this study, the DEJ structure in bovine incisors was studied with synchrotron microComputed Tomography (microCT) using small cubes cut parallel to the tooth surface. The reconstructions revealed a zone of highly variable punctate contrast between bulk dentin and enamel; the mean linear attenuation coefficients and their standard deviations demonstrated that this zone averaged less mineral than dentin or enamel but had more highly variable structure than either. The region with the punctuate contrast is, therefore, the mantle dentin. The thickness of the mantle dentin seen in a typical data set was about 30 mu m, and the mantle dentin-enamel interface deviated +/- 15 mu m from the average plane over a distance of 520 mu m. In the highest resolution data (similar to 1.5 mu m isotropic voxels, volume elements), tubules in the dentin could be discerned in the vicinity of the DEJ. Contrast sensitivity was high enough to detect differences in mineral content between near-surface and near-DEJ volumes of the enamel. Reconstructions before and after two cubes were compressed to failure revealed cracks formed only in the enamel and did not propagate across the mantle dentin, regardless of whether loading was parallel to or perpendicular to the DEJ. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
This study analyzed degrees of demineralization in bovine enamel using synchrotron microcomputed tomography (SMCT) and hardness measurements (Knoop hardness number, KHN). For 5 days, 40 bovine enamel blocks were individually subjected to a pH cycling model and treatment with fluoride dentifrices (placebo, 275, 550 and 1,100 mu g F/g) diluted in deionized water twice a day. Surface hardness number and cross-sectional profiles of hardness and mineral concentration (by SMCT) were determined. Integrated hardness (KHN x mu m) for sound and demineralized specimens was calculated and subtracted to give the integrated loss of hardness (Delta KHN) for the lesions. Increasing fluoride concentration in the dentifrices led to higher values for surface hardness after pH cycling and mineral concentration (g(HAp) cm(-3)), and lower values for Delta KHN (p < 0.05). From the present results, it may be concluded that hardness measurements revealed demineralization in all groups, which was lower in groups treated with dentifrice with a higher F concentration. SMCT and hardness measurements gave similar results in areas with higher demineralization, but diverged in areas with lower demineralization. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)