71 resultados para Chromatographic method
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Sickle cell anemia (SCA) shows a pathophysiology that involves multiple changes in sickle cell erythrocytes, vaso-occlusive episodes, hemolysis, activation of inflammatory mediators, endothelial cell dysfunction, and oxidative stress. These events complicate treatment and culminate in the development of manifestations such as anemia, pain crises and multiorgan dysfunction. The aim of this study was to evaluate, in SCA patients, oxidative stress and antioxidant capacity markers, correlating them to treatment with hydroxyurea (HU), β-globin haplotypes and glutathione S-transferase polymorphisms (GSTT1, GSTM1 and GSTP1), in comparison to a control group (CG). The study groups were composed of 48 individuals without hemoglobinopathies (CG), SCA patients treated with HU [AF (+HU), N = 13] and untreated SCA patients [AF (-HU), N = 15], after informed consent. The groups were analyzed using cytological, electrophoretic, chromatographic and molecular methods and information from medical records. The GSTM1 and GSTT1 polymorphisms were determined by multiplex PCR, while the GSTP1 polymorphism by PCR-RFLP. Biochemical parameters were measured using spectrophotometric methods [TBARS, TEAC and catalase (CAT) and GST activities] and a chromatographic method [glutathione (GSH)]. The fetal Hb (Hb F) levels observed in the SCA (+HU) group (10.9%) confirmed the already well-described pharmacological effect of HU, but the SCA (-HU) group also had high Hb F levels (6.1%), which may have been influenced by genetic factors not targeted in this study. We found a higher frequency of the Bantu haplotype (48.2%), followed by the Benin (32.1%) and also Cameroon haplotypes, rare in our population, and 19.7% of atypical haplotypes. The presence of Bantu haplotype was related to higher lipid peroxidation levels in patients, but also, it conferred a differential response to HU treatment, raising Hb F levels in 52.6% (P = 0.03). The protective effect of Hb F was confirmed, because the increase in their levels resulted in a 41.3% decrease in lipid peroxidation levels (r = -0.74, P = 0.0156). The genotypic frequency of the GST polymorphisms observed was similar to that of other studies in the Brazilian population, and its association with biochemical markers revealed a significant difference only for the GSTP1 polymorphism, where patients with genotype V/V showed higher GSH and TEAC levels (P = 0.04 and P = 0.03, respectively) compared to patients with genotype I/I. The TBARS levels were about five to eight times higher in the SCA (+HU) and SCA (-HU) groups, respectively, compared to controls, and HU produced a 35.2% decrease in lipid peroxidation levels in the SCA (+HU) group (P < 0.0001). Moreover, the SCA (+HU) group showed higher TEAC levels when compared to CG (P = 0.002). We did not find any significant difference in GST activity between the groups studied (P = 0.76), but CAT activity was about 17 and 30% lower in SCA (+HU) and SCA (-HU) groups, respectively (P < 0.00001). Plasma GSH levels were ~2 times higher in SCA patients than in the control group (P = 0.0005) and showed a positive correlation with TBARS levels, confirming its antioxidant function. HU treatment contributed to higher CAT activity and TEAC levels and lower lipid peroxidation, and its pharmacological effect showed a “haplotype-dependent” response. These findings may contribute to elucidating the potential of HU in ameliorating oxidative stress in SCA subjects.
Resumo:
In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.
Resumo:
An accurate, sensitive, precise and rapid reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of caffeic acid (CA) in emulsions. The best separation was achieved on a 250 × 4.6 mm, 5.0 µm particle size RP18 XDB Waters column using ethanol and purified water (40:60 v/v) adjusted to pH 2.5 with acetic acid as the mobile phase at a flow rate of 0.7 mL/min. Ultraviolet detection was performed at 325 nm at ambient column temperature (25°C). The method was linear over the concentration range of 10-60 µg/mL (r(2) = 0.9999) with limits of detection and quantification of 1.44 and 4.38 µg/mL, respectively. CA was subjected to oxidation, acid, base and neutral degradation, as well as photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of CA. The method was applied to the determination of CA in standard and pharmaceutical products with excellent recoveries. The method is applicable in the quality control of CA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
A total of 2400 samples of commercial Brazilian C gasoline were collected over a 6-month period from different gas stations in the São Paulo state, Brazil, and analysed with respect to 12 physicochemical parameters according to regulation 309 of the Brazilian Government Petroleum, Natural Gas and Biofuels Agency (ANP). The percentages (v/v) of hydrocarbons (olefins, aromatics and saturated) were also determined. Hierarchical cluster analysis (HCA) was employed to select 150 representative samples that exhibited least similarity on the basis of their physicochemical parameters and hydrocarbon compositions. The chromatographic profiles of the selected samples were measured by gas chromatography with flame ionisation detection and analysed using soft independent modelling of class analogy (SIMCA) method in order to create a classification scheme to identify conform gasolines according to ANP 309 regulation. Following the optimisation of the SIMCA algorithm, it was possible to classify correctly 96% of the commercial gasoline samples present in the training set of 100. In order to check the quality of the model, an external group of 50 gasoline samples (the prediction set) were analysed and the developed SIMCA model classified 94% of these correctly. The developed chemometric method is recommended for screening commercial gasoline quality and detection of potential adulteration. (c) 2007 Elsevier B.V. All rights reserved.