104 resultados para Ballasts (lamp)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Locomotion generates a visual movement pattern characterized as optic flow. To explore how the locomotor adjustments are affected by this pattern, an experimental paradigm was developed to eliminate optic flow during obstacle avoidance. The aim was to investigate the contribution of optic flow in obstacle avoidance by using a stroboscopic lamp. Ten young adults walked on an 8m pathway and stepped over obstacles at two heights. Visual sampling was determined by a stroboscopic lamp (static and dynamic visual sampling). Three-dimensional kinematics data showed that the visual information about self-motion provided by the optic flow was crucial for estimating the distance from and the height of the obstacle. Participants presented conservative behavior for obstacle avoidance under experimental visual sampling conditions, which suggests that optic flow favors the coupling of vision to adaptive behavior for obstacle avoidance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquatic humic substances (AHS) isolated from two characteristic seasons of the Negro river, winter and summer corresponding to floody and dry periods, were structurally characterized by (13)C nuclear magnetic ressonance. Subsequently, AHS aqueous solutions were irradiated with a polychromatic lamp (290-475 nm) and monitored by its total organic carbon (TOC) content, ultraviolet-visible (UV-vis) absorbance, fluorescence and Fourier transformed infrared spectroscopy (FTIR). As a result, a photobleaching upto 80% after irradiation of 48 h was observed. Conformational rearrangements and formation of low molecular complexity structures were formed during the irradiation, as deduced from the pH decrement and the fluorescence shifting to lower wavelengths. Additionally a significant mineralization with the formation of CO(2), CO, and inorganic carbon compounds was registered, as assumed by TOC losses of up to 70%. The differences in photodegradation between samples expressed by photobleaching efficiency were enhanced in the summer sample and related to its elevated aromatic content. Aromatic structures are assumed to have high autosensitization capacity effects mediated by the free radical generation from quinone and phenolic moieties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho foi conduzido na Pista de Ensaios de Semeadura do Laboratório de Máquinas e Mecanização Agrícola (LAMMA) da UNESP/Jaboticabal - SP, para o estudo da ação da roda compactadora de semeadoras sob cargas verticais, na deformação do solo, com dois teores de água. Os tratamentos consistiram da combinação de dois teores de água e seis cargas verticais, totalizando 12 tratamentos, com três repetições, em dois ensaios, analisando-se a resistência mecânica do solo à penetração e a deformação do solo provocada pela roda compactadora. A roda compactadora utilizada era de alumínio, com massa de 6,4 kg, 40 cm de diâmetro e 10 cm de largura, sob a ação de cargas verticais de 63; 161; 259; 357; 455 e 553 N, obtidas acoplando-se lastros de chumbo sobre a roda compactadora, sendo os teores de água do solo de 15,4 e 9,2%. Os resultados permitem concluir que o teor de água do solo tem grande influência na deformação e compactação do solo, que aumentam proporcionalmente com as cargas verticais sobre a roda compactadora, e que, quanto maior o teor de água do solo, mais suscetível o mesmo fica à compactação e deformação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compararam-se os efeitos sedativos e antinociceptivos da romifidina (0,1mg/kg) e da xilazina (1,0mg/kg) em éguas da raça Puro Sangue Inglês. A sedação foi quantificada por meio da atividade locomotora espontânea (ALE) e altura da cabeça (AC) em baias individuais automatizadas para o estudo do comportamento. A antinocicepção foi avaliada utilizando uma lâmpada de irradiação de calor registrando-se a latência para o reflexo de retirada do membro (LRRM) e a latência para o reflexo do frêmito cutâneo (LRFC), em delineamento experimental em blocos ao acaso com 10 repetições. O efeito sedativo sobre a ALE foi de aparecimento mais rápido no grupo exposto à xilazina, ao passo que a ptose da cabeça foi mais prolongada no grupo que recebeu romifidina. A romifidina promoveu aumento da LRRM e LRFC e a xilazina não causou efeito antinociceptivo medido pela LRFC. O efeito antinociceptivo da romifidina foi mais pronunciado que o da xilazina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ferroelectric SrBi2Ta2O9 thin films on Pt/Ti/SiO2/Si were successfully synthesized by the modified polymeric precursor method. The films were deposited by spin coating and crystallized by rapid thermal annealing in a halogen lamp furnace, followed by postannealing at temperatures ranging from 700 degreesC to 800 degreesC in an oxygen atmosphere. Microstructural and phase evaluations were followed by x-ray diffraction and atomic force microscopy. The films displayed spherical grain structures with a superficial roughness of approximately 3-6 nm. The dielectric constant values were 121 and 248 for films treated at 700 degreesC and 800 degreesC, respectively. The P-E curve showed a voltage shift toward the positive side, which was attributed to crystallization under the halogen illumination. The remanent polarization (2P(r)) and coercive field (E-c) were 7.1 muC/cm(2) and 113 kV/cm, and 18.8 muC/cm(2) and 93 kV/cm for the films treated at 700 degreesC and 800 degreesC, respectively. (C) 2001 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To possibly reduce postoperative adhesions that occur after ocular myoplasties, we investigated the topical effects of 0.04% mitomycin C on the repaired areas of the medial rectus muscle using an equine renal capsule preserved in 98% glycerin for reinforcement of the sutures. Twenty-four rabbits, divided into two groups of 12 animals each [untreated (control) and treated group (MMC)], were submitted to surgical rupture of the medial rectus muscle of one eye and repair of the defect 24 h later with sutures and an equine renal capsule. Post-operative prophylactic treatment of the two groups consisted of the administration of eye drops containing neomycin, polymyxin B and dexamethasone at regular 6-h intervals for eight consecutive days and daily rinsing with physiological saline. MMC animals received additional treatment with topical 0.04% mitomycin C every 6 h for 14 consecutive days. Slit lamp biomicroscopy showed greater irritation of the ocular surface in MMC animals during the first days post operatively. Adhesions were observed at 15 and 30 days of assessment in the two groups, but were more extensive in control animals at 60 days. Histopathology revealed inflammatory exudation in both groups, which was greater in MMC animals. Mitomycin C (0.04%) instilled at 6-h intervals for 14 consecutive days reduced the occurrence of fibrosis in the myoplastic areas. However, the equine renal capsule was found to be of little benefit for the reinforcement of myoplasties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electro-optical properties of sol-gel derived 2 mol% antimony or niobium doped tin dioxide films have been measured. The electron density has been calculated considering all the relevant scattering mechanisms and experimental conductivity data measured in the range -197 to 25 degrees C. The results support the hypothesis that both ionised impurity scattering and grain boundary scattering have comparable effects in the resistivity of coatings, for free electron density congruent to 5 x 10(18) cm(-3). We have measured variation of photoconductivity excitation with wavelength using xenon and deuterium lamp as light sources. Results show that the main band in the photoconductivity spectrum is dependent on the spectral light source emission, the excitation peak reaching 5 eV (deuterium lamp). This band is due to the recombination process involving oxygen species and photogenerated electron-hole pairs. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective-To investigate spontaneous locomotor activity (SLA) and antinociceptive effects of buprenorphine in horses.Animals-6 healthy adult horses.Procedures-Horses received each of 3 treatments (10 mL of saline [0.9% NaCl] solution, 5 mu g of buprenorphine/kg, or 10 mu g of buprenorphine/kg). Treatments were administered IV Order of treatments was randomized, and there was a 10-day interval between subsequent treatments. Spontaneous locomotor activity was investigated in a behavioral box by use of infrared photoelectric sensors connected to a computer, which detected movement of each horse. Antinociceptive effect was investigated by hoof-withdrawal reflex latency (HWRL) and skin-twitching reflex latency (STBL) after painful stimulation with a heat lamp.Results-Moderate excitement was observed in all horses from 5 to 10 minutes after the administration of both dosages of buprenorphine. The SLA increased significantly for 6 and 14 hours after IV administration of 5 and 10 mu g of buprenorphine/kg, respectively. Values for HWRL increased significantly only at 30 minutes after injection of 5 mu g of buprenorphine/kg, whereas STRL and HWRL each increased significantly from 1 to 6 hours (except at 2 and 4 hours) and 11 hours, respectively, after injection of 10 mu g of buprenorphine/kg.Conclusions and Clinical Relevance-IV injection of buprenorphine caused a dose-dependent increase in SLA, but only the dose of 10 mu g/kg induced analgesia on the basis of results for the experimental method used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present photoluminescence and decay of photo excited conductivity data for sol-gel SnO(2) thin films doped with rare earth ions Eu(3+) and Er(3+), a material with nanoscopic crystallites. Photoluminescence spectra are obtained under excitation with several monochromatic light sources, such as Kr(+) and Ar(+) lasers, Xe lamp plus a selective monochromator with UV grating, and the fourth harmonic of a Nd: YAG laser (4.65eV), which assures band-to-band transition and energy transfer to the ion located at matrix sites, substitutional to Sn(4+). The luminescence structure is rather different depending on the location of the rare-earth doping, at lattice symmetric sites or segregated at grain boundary layer, where it is placed in asymmetric sites. The decay of photo-excited conductivity also shows different trapping rate depending on the rare-earth concentration. For Er-doped films, above the saturation limit, the evaluated capture energy is higher than for films with concentration below the limit, in good agreement with the different behaviour obtained from luminescence data. For Eu-doped films, the difference between capture energy and grain boundary barrier is not so evident, even though the luminescence spectra are rather distinct.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since oxygen vacancies act as donors in SnO2, the electrical properties are related to deviation from stoichiometric composition. Depending on stoichiometry SnO2 can be highly insulating or may exhibit fairly high n-type conductivity. Since bandgap transitions are in the ultraviolet range, its photoconductivity is strongly dependent on the excitation source. We have measured variation of photoconductivity excitation with wavelength for tin dioxide grown by dip-coating sol-gel technique using several light sources: tungsten lamp, xenon, mercury and deuterium, and present selected results. The main band is obtained in the range 3-4eV according to light source spectrum in the ultraviolet range. The presence of oxygen in the cryostat also affects the spectrum since electron-hole pairs react with adsorbed oxygen specimens. © 1999 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The photo-Fenton process using potassium ferrioxalate as a mediator in the photodegradation reaction of organochloride compounds in an aqueous medium was investigated. The influence of parameters such as hydrogen peroxide and ferrioxalate concentrations and initial pH, was evaluated using dichloroacetic acid (DCA) as a model compound under black-light lamp irradiation. An upflow annular photoreactor, operating in a single pass or recirculating mode was used during photodegradation experiments with artificial light. The extent of the release of chloride ions was used to evaluate the photodegradation reaction. The optimum pH range observed was 2.5-2.8. The efficiency of DCA dechlorination increased with increasing concentrations of H2O2 and potassium ferrioxalate, reaching a plateau after the addition of 6 and 1.5 mmol/L of those reagents, respectively. The total organic carbon (TOC) content in DCA and 2,4-dichlorophenol (DCP) solutions was compared with the chloride released after photodegradation. The influence of natural solar light intensity, measured at 365 nm, was evaluated for the dechlorination of DCA on typical summer's days showing a linear dependency. The photodegradation of DCA using black-light lamp and solar irradiation was compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance. © Mary Ann Liebert, Inc.