38 resultados para Anaerobic exercise
Resumo:
The aim of this study was to validate a non-invasive protocol to determine aerobic and anaerobic capacity of treadmill running rats. Thirteen male Wistar rats (90 days old) were submitted to 4 exercise tests, consisting of running at 25, 30, 35 and 40 m min-1, continuously until exhaustion. For the critical velocity (CV) and anaerobic running capacity (ARC) estimations, the hyperbolic curve (velocity versus time to exhaustion (tlim)) was linearized to V= CV+ARC/tlim, where the CV and ARC were linear and slope coefficients, respectively. In order to verify if the CV was the maximal aerobic intensity, the rats were submitted to the maximal lactate steady state test (MLSS) composed of three 25-minute tests of continuous running trials at 15, 20 and 25 m min-1, with blood collection every 5 minutes. The CV was obtained at 22.8±0.7 m min-1 and the ARC, at 26.80±2.77 m. The MLSS was observed at 20m min-1, with blood lactate 3.84 ± 0.31 mmol L-1. There was a progressive increase in lactate concentration at 25 m min-1. The CV and MLSS were different, but presented a high and significant correlation (r=0.81). These results indicate that the non-invasive protocol can be used for physical evaluation of aerobic running rats, but the ARC should still be further investigated.
Resumo:
The purpose of this study was to investigate whether the critical force (CritF) and anaerobic impulse capacity (AIC) - estimated by tethered swimming - reflect the aerobic and anaerobic performance of swimmers. 12 swimmers performed incremental test in tethered swimming to determine lactate anaerobic threshold (AnTLAC), maximal oxygen uptake (̇VO2MAX) and force associated with the ̇VO2MAX (i ̇VO2MAX). The swimmers performed 4 exhaustive (tlim) exercise bouts (100, 110, 120 and 130% i ̇VO2MAX) to compute the CritF and AIC (F vs. 1/tlim model); a 30-s all-out tethered swimming bout to determine their anaerobic fitness (ANF); 100, 200, and 400-m time-trials to determine the swimming performance. CritF (57.09±11.77 N) did not differ from AnTLAC (53.96±11.52 N, (P>0.05) but was significantly lower than i ̇VO2MAX (71.02±8.36 N). In addition, CritF presented significant correlation with AnTLAC (r=0.76; P<0.05) and i ̇VO2MAX (r=0.74; P<0.05). On the other hand, AIC (286.19±54.91 N.s) and ANF (116.10±13.66 N) were significantly correlated (r=0.81, p<0.05). In addition, CritF and AIC presented significant correlations with all time-trials. In summary, this study demonstrates that CritF and AIC can be used to evaluate AnTLAC and ANF and to predict 100, 200, and 400-m free swimming. © Georg Thieme Verlag KG Stuttgart . New York.
Resumo:
To assess the effects of continuous exercise training at intensities corresponding to 80 and 90 % of the lactate minimum test (LM), we evaluated antioxidant activity, hormone concentration, biochemical analyses and aerobic and anaerobic performance, as well as glycogen stores, during 12 weeks of swimming training in rats. One-hundred rats were separated into three groups: control (CG, n = 40), exercise at 80 (EG80, n = 30) and 90 % (EG90, n = 30) of LM. The training lasted 12 weeks, with sessions of 60 min/day, 6 days/week. The intensity was based at 80 and 90 % of the LM. The volume did not differ between training groups (Ẋ of EG80 = 52 ± 4 min; Ẋ of EG90 = 56 ± 2 min). The glycogen concentration (mg/100 mg) in the gastrocnemius increased after the training in EG80 (0.788 ± 0.118) and EG90 (0.795 ± 0.157) in comparison to the control (0.390 ± 0.132). The glycogen stores in the soleus enhanced after the training in EG90 (0.677 ± 0.230) in comparison to the control (0.343 ± 0.142). The aerobic performance increased by 43 and 34 % for EG80 and EG90, respectively, in relation to baseline. The antioxidant enzymes remain unchanged during the training. Creatine kinase (U/L) increased after 8 weeks in both groups (EG80 = 427.2 ± 97.4; EG90 = 641.1 ± 90.2) in relation to the control (246.9 ± 66.8), and corticosterone (ng/mL) increased after 12 weeks in EG90 (539 ± 54) in comparison to the control (362 ± 44). The continuous exercise at 80 and 90 % of the LM has a marked aerobic impact on endurance performance without significantly biomarkers changes compared to control. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
The aim of this study was to investigate the possible influence of different levels of aerobic fitness (VO2MAX) on the parameters of the running anaerobic sprint test (RAST). Thirty-eight subjects (Age = 18.1 ± 2.5 years, Height = 173 ± 1 cm and Body mass = 65.1 ± 6.5 kg) were classified into two groups, low and high aerobic fitness (LAF: n = 22 and HAF: n = 16). The VO2MAX was determined by an incremental exercise performed until exhaustion. The RAST was composed of six maximal efforts of 35m separated by 10s passive recovery. The VO2MAX was significantly different between groups (LAF = 51.7 ± 1.9 mL.kg -1.min-1; HAF = 58.6 ± 3.1 mL.kg -1.min-1). The mean power (MP) was significantly higher in the LAF (552.7 ± 132.1 W) in relation to the HAF group (463.6 ± 132.8 W). The impulse (ImP) was significantly correlated with the VO 2MAX in HAF. It can be concluded that there is an indication that the aerobic metabolism exerts an influence on the completion of RAST.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose The purpose of the study was to investigate a possible association between the distance covered in the Hoff test with parameters of maximal oxygen uptake (V_O2MAX), anaerobic threshold, anaerobic fitness, and body composition of professional adult soccer players. Methods Twenty-five professional soccer players (20 ± 3 years) participated in the study. On different days the athletes performed: a graded incremental exercise test in a laboratory to measure V_O2MAX; a specific soccer field test called the Hoff test; a running anaerobic sprint test (RAST); an incremental test on an oval circuit to determine the velocity relative to anaerobic threshold (VAnT) and an estimation of body composition. Results The average V_O2MAX corresponded to 4.1 ± 0.1 L min-1 (54.1 ± 1.2 mL kg-1 min-1 ). The average distance covered during the Hoff test was 1,442.4 ± 30.0 m. The distance covered during the Hoff test showed significant correlations with absolute and expressed in an appropriated scale V_O2MAX (r = 0.44, p = 0.02; r = 0.42, p = 0.02, respectively) while no significant differences were found with body composition, VAnT and RAST variables. Conclusions The present study demonstrated that the distance covered during the Hoff test has weak correlation with V_O2MAX determined in treadmill running, and no correlation with VAnT, body composition and RAST outcomes, probably due to the non-specificity of the proposed tests when associated with the Hoff test.