47 resultados para Amplifier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased fuel economy and driveability of modern internal combustion engine vehicles (ICEVs) are the result of the application of advanced digital electronics to control the operation of the internal combustion engine (ICE). Microprocessors (and micro controllers) play a key role in the engine control, by precisely controlling the amount of both air and fuel admitted into the cylinders. Air intake is controlled by utilizing a throttle valve equipped with a motor and gear mechanism as actuator, and a sensor enabling the measurement of the angular position of the blades. This paperwork presents a lab setup that allows students to control the throttle position using a microcontroller that runs a program developed by them. A commercial throttle body has been employed, whereas a power amplifier and a microcontroller board have been hand assembled to complete the experimental setup. This setup, while based in a high-tech, microprocessor-based solution for a real-world, engine operation optimization problem, has the potential to engage students around a hands-on multidisciplinary lab activity and ignite their interest in learning fundamental and advanced topics of microprocessors systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring non-ionizing radiant energy is increasingly demanded for many applications such as automobile, biomedical and security system. Thermal type infrared (IR) sensors can operate at room temperature and pyroelectric materials have high sensitivity and accuracy for that application. Working as thermal transducer pyroelectric sensor converts the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. In the present study the composite made of poly(vinylidene fluoride) -PVDF and lead zirconate titanate (PZT) partially recovered with polyaniline (PAni) conductor polymer has been used as sensor element. The pyroelectric coefficient p(T) was obtained by measuring the pyroelectric reversible current, i.e., measuring the thermally stimulated depolarization current (TSDC) after removing all irreversible contribution to the current such as injected charge during polarization of the sample. To analyze the sensing property of the pyroelectric material, the sensor is irradiated by a high power light source (halogen lamp of 250 W) that is chopped providing a modulated radiation. A device assembled in the laboratory is used to change the light intensity sensor, an aluminum strip having openings with diameters ranging from 1 to 10 mm incremented by one millimeter. The sensor element is assembled between two electrodes while its frontal surface is painted black ink to maximize the light absorption. The signal from the sensor is measured by a Lock-In amplifier model SR530 -Stanford Research Systems. The behavior of the output voltage for an input power at several frequencies for PZT-PAni/PVDF (30/ 70 vol%) composite follows the inverse power law (1/ f) and the linearity can be observed in the frequency range used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of multimodal neuroimaging techniques has been helpful in the investigation of epileptogenic zone in patients with refractory epilepsies. This work aims to describe an ictal event during EEG-fMRI performed simultaneously in a 39-year-old man with refractory epilepsy. The EEG data were recorded at a sampling rate of 5 kHz, using a BrainAmp (BrainProducts, München, Germany) amplifier, with 64 MR (magnetic resonance) compatible Ag/AgCl electrodes. MR images were acquired using a 3T scanner in 3 sequences of 6 minutes of echo-planar images (EPIs), with TR = 2s, being the last sequence stopped after the ictal event. The EEG was corrected for gradient and pulse artifacts using the Brain Vision Analyzer2 software (BrainProducts), and the functional images were realigned, slice-timing corrected, normalized and smoothed. The start of the ictal changes was used for the evaluation of the BOLD response in MR images, using a t-test with a minimum cluster of 5 voxels, p <0.005 (T>2.5). The patient had a partial complex seizure, as noted by neurologist. The fMRI data showed positive BOLD responses (activation) in dysplastic areas, but showed the most significant activation outside the lesion, in areas compatible with secondary spread of the epileptic focus, probably caused by motor reaction also observed during the seizure. As a conclusion, we note that the technique of EEG-fMRI can detect the epileptogenic zone in patients with refractory epilepsy, but areas of dissemination of primary epileptogenic focus may show significant activation, introducing additional difficulties to the interpretation of the results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report the development of a tube amplifier built to be used in magnetic probe diagnostic of plasma. The probe is used to measure the magnetic field in the theta-pinch system presently running in our university. We present the calculations and procedures to determine the configuration of circuits and specify the components of the power supply, the preamp stage and the power stage. The circuit configuration and the characteristics of the components was obtained. A representative model of the system behavior gave the transfer function of the amplifier. Theoretical predictions of frequency response and the feedback effects were compared to the experimental values and showed very good agreement. The amplifier works between a frequency bandwidth of 20 an 30 kHz and supply a maximum power of 12 W

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the development of a graphical interface to the Lock-in Amplifier, which is used in physiological studies on the motility of the gastrointestinal tract in rats and signal processing. With a simple and low cost instrumentation, the resources offered by the virtual interface of LabVIEW software allows the creation of commands similar to the actual instrument that, through communication via standard serial port, transmits data between a PC and peripheral device performing specific and particular needs in the amplifier. Created for the lock-in amplifier model SR830 Stanford Research Systems, the remote manipulation gives the user greater accessibility in the process of configuration and calibration. And, since the software is installed, there is the advantage of eliminating the need of purchase new devices to upgrade the system. The commands created were made to perform six basic modifications that are used in routine of the Biomagnetism Laboratory. The instrumentation developed has the following controls: Amplitude, Frequency, Time Constant, slope low pass filter, sensitivity and offset

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS