87 resultados para Airway devices
Resumo:
The effects of the degradation process on the structural, microstructural and electrical properties of ZnO-based varistors were analyzed. Rietveld refinement showed that the BiO2-x phase is affected by the degradation process. Besides the changes in the spinel phase, the degradation process also affects the lattice microstrain in the ZnO phase. Scanning electron microscopy analysis showed electrode-melting failure, while wavelength dispersive X-ray spectroscopy qualitative analysis showed deficiency of oxygen species at the grain boundaries in the degraded samples. Atomic force microscopy using electrostatic mode force illustrated a decrease in the charge density at the grain boundaries of the degraded sample. Transmission electron microscopy showed submicrometric spinel grains embedded in a ZnO matrix, but their average grain size is smaller in the degraded sample than in the standard one. Long pulses appeared to be more harmful for the varistors' properties than short ones, causing higher leakage current values. The electrical characteristics of the degraded sample are partially restored after heat treatment in an oxygen-rich atmosphere. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: This study evaluated oropharyngeal airway changes and stability following surgical counter-clockwise rotation and advancement of the maxillo-mandibular complex.Methods and Patients: Fifty-six adults (48 females, 8 males), between 15 and 51 years of age, were treated with Le Fort I osteotomies and bilateral mandibular ramus sagittal split osteotomies to advance the maxillo-mandibular complex with a counter-clockwise rotation. The average postsurgical follow-up was 34 months. Each patient's lateral cephalograms were traced, digitized twice, and averaged to estimate Surgical changes (T2-T1) and Postsurgical changes (T3-T2).Results: During surgery, the occlusal plane angle decreased significantly (8.6 +/- 5.8 degrees) and the maxillo-mandibular complex advanced and rotated counter-clock-wise. The maxilla moved forward (2.4 +/- 2.7 mm) at ANS and the mandible was advanced 13.1 +/- 5.1 min at menton, 10 +/- 4.4 mm at point B, and 6.9 +/- 3.7 mm at lower incisor edge. Postsurgical hard tissue changes were not statistically significant. While the upper oropharyngeal airway decreased significantly (4.2 +/- 3.4 min) immediately after surgery, the narrowest retropalatal, lowest retropalatal airway, and the narrowest retroglossal airway measurements increased 2.9 +/- 2.7, 3.7 +/- 3.2, and 4.4 +/- 4.4 mm, respectively. Over the average 34 months Postsurgical period, upper retropalatal airway increased 3.9 +/- 3.7 mm, while narrowest retropalatal, lowest retropalatal airway, and narrowest retroglossal airway remained stable. Head posture showed flexure immediately after Surgery (4.8 +/- 5.9 degrees) and extension postsurgically (1.6 +/- 5.6 degrees).Conclusion: Maxillo-mandibular advancement with counter-clockwise rotation produces immediate increases in middle and lower oropharyngeal airway dimensions, which were constrained by changes in head posture but remain stable over the postsurgical period. The upper oropharyngeal airway space increased only on the longest follow-up. (C) 2006 American Association of Oral and Maxillofacial Surgeons.
Resumo:
We report on light-emitting devices based on a green-phosphor compound (Mn-doped zinc silicate, Zn2SiO4: Mn) dispersed in a conductive polymeric blend (poly-o-methoxyaniline/polyvinylene fluoride, POMA/PVDF-TrFE). The devices exhibited high luminance in the green, good stability and homogeneous brilliance over effective areas up to 5 cm(2). The electroluminescence (EL) spectrum presented essentially the same characteristics as the photoluminescence (PL) and cathodoluminescence spectra, indicating that the light emission originates from decay of the same excited species, regardless of the excitation source. Operating characteristics were analyzed with current density - voltage (J - V) and luminance voltage ( L - V) curves to investigate the nature of the electroluminescence of the active material, which is still not completely understood.
Resumo:
Objectives: To evaluate the effect of increased of laryngeal mask airway (LMA) intracuff pressures on the laryngopharyngeal mucosa. Study Design: Animal model. Methods: Sixteen mixed-breed dogs were randomly allocated to two groups, G1 (intracuff volume, 30 mL; n = 8) and G2 (intracuff volume, 54 mt; n = 8), to produce, respectively, high or very high intracuff pressures. Anesthesia was induced and maintained with pentobarbital. Intracuff pressures were measured immediately after insertion and inflation of a No. 4 laryngeal mask airway (LMA) and 30, 60, 90, and 120 minutes thereafter. The dogs were euthanized, and biopsy specimens from eight predetermined areas of the laryngopharynx in contact with LMA cuff were collected for light microscopic (LM) and scanning electron microscopic (SEM) examination. Results: Initial LMA cuff inflation in G1 and G2 resulted in intracuff pressures of 119 mm Hg +/- 4 mm Hg and 235 mm Hg +/- 13 mm Hg, respectively. Over a 2-hour period, the intracuff pressure decreased significantly in G1 (P < .001) and G2 (P < .01), and there was a significant difference between the groups over time (P < .001). The LM study of laryngopharyngeal mucosa in both groups showed mild congestion in the subepithelial layer. There were no differences between the groups (P > .10) or among the areas sampled (P > .10). In some areas of G2, the SEM study showed epithelial desquamation that was more intense than that in GI. Conclusions: the increase in LMA intracuff pressure caused only mild alterations in the laryngopharyngeal mucosa of the dog.
Resumo:
This paper discuss the qualitative use of electrostatic force microscopy to study the grain boundary active potential barrier present in dense SnO2-based polycrystalline semiconductors. The effect of heat treatment under rich- and poor-oxygen atmospheres was evaluated while especially considering the number of active barriers at grain boundary regions. The results show that the number of active barriers decrease after heat treatment in an oxygen-poor atmosphere and increase after heat treatment in oxygen-rich atmospheres. The observed effect was explained by considering the presence of oxidized transition metal elements segregated at grain boundary regions which leads to the p-type character of this region, in agreement with the atomic barrier formation mechanism in metal oxide varistor systems.
Resumo:
The main purpose of this work is to evaluate the failure caused by electrical discharge on commercial ZnO varistor doped with oxide of Bi, Sb, Si, Cr, Co utilized in electric transmission systems. In order to observe the effect of electrical discharge over the microstructure and electrical properties of the varistors, two kinds of pulses were applied: long pulse (2000 ms) and short pulse (8/20 mu s). In both cases, a decrease in grain size and increase in micropores and leakage current were observed. The degraded samples present oxygen defficiency mainly in the grain boundary and phase tranformation from the bismuth oxide phase. (c) 2005 Springer Science+ Business Media, Inc.
Resumo:
In this paper a modified chalcogenide glass was studied by X-ray powder diffraction, differential thermal analysis, infrared and Raman scattering spectroscopies. The study of this new matrix opens new perspectives to fabricate Pr3+-doped fibers to operate as an optical amplifier in the 1.3 mum telecommunications window. The Pr3+-doped 70Ga(2)S(3)-30La(2)S(3) glass was modified through the substitution of La2S3 by La2O3, which improves the thermal stability of these glasses without any modification of phonon energy. The possibility to pull a fiber from this glass system without any devitrification is easily achieved.
Resumo:
In the present work, electroactive grain boundaries of highly dense metal oxide SnO2-based polycrystalline varistors were determined by electrostatic force microscopy (EFM). The EFM technique was applied to identify electroactive grain boundaries and thus estimate the amount of active grain boundary, which, in the metal oxide SnO2-based varistor, was calculated at around 85%, i.e., much higher than that found in traditional metal oxide ZnO-based varistors. The mean potential barrier height value obtained from the EFM analysis was in complete agreement with the values calculated from the C-V measurements, together with a complex capacitance plane analysis that validates the methodology proposed here. (c) 2006 American Institute of Physics.
Resumo:
The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)