83 resultados para Ac biosusceptometry
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images
Resumo:
Several hormonal and physiological changes that occur during pregnancy directly affect gastrointestinal motility (GI), however, very little is known about the relationship between the electrical and mechanical activities of the stomach and its implications. The aim of this study was to compare the female sex hormones, with profiles of gastrointestinal motility using AC biosusceptometry (BAC) in pregnant rats. Seven female Wistar rats (weighing 250-350 g) were used and all procedures were approved by the local Ethics Committee of animal. Laparotomy was performed on anesthetized rats and a magnetic marker (3.5 mm in diameter and 3.0 mm height) was implanted in the distal stomach. After 10 days of recuperation, the mice were put to mate until confirmation of pregnancy. Fed animals were anesthetized (mg pentobarbital 30 / kg) and kept supine for recording the signal with a sensor 30 min BAC placed on the abdominal surface on days 0, 7, 14 and 20 of gestation. Statistical analysis was performed by Student's t test statistical Newman-Keuls and a P value of .05 was considered statistically significant. The frequency of contraction of the stomach was 74 mHz ± 3, 67 ± 7 mHz, 59 mHz ± 6 (p <0.05 vs day -1) and 71 ± 5 mHz on days -0, -7, -14, and -20, respectively. The values of 44 ± 15 pg / mL and 31 ± 9 pg / ml 25 ± 6 pg / ml, 22 ± 9 pg / ml on days -0, -7, -14 and -20, respectively, obtained by 17ß- estradiol were not statistically significant. The values of progesterone were 13 ± 6 pg / ml at 54 ± 15 pg / ml, 127 ± 42 pg / ml (p <0.05 vs day-1), 22 ± 13 pg / mL on day -0, - 7, -14 and -20, respectively. A linear correlation (Pearson's test) between the lower frequency gastric and increased levels of progesterone was 80% (p <0.0000001). Until then, the relationship between changes in motility and hormone were not described in detail, but with the work that we were able to demonstrate the high correlation between progesterone concentration ...
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Ao administrar um fármaco, devem ser considerados fatores como a forma farmacêutica apropriada, a via de administração com maior eficiência e o que será mais bem aceita pelo paciente. Formas farmacêuticas sólidas (FFS), tais como comprimidos, representam a principal escolha, pois são fáceis de preparar, armazenar, transportar e são bem aceitas pelos pacientes. Porém, a absorção dos fármacos administrados em comprimidos depende do processo de desintegração, ou seja, um processo tempo-dependente que ocorre sob a ação de um desintegrante que promove a fragmentação da forma farmacêutica em partículas passíveis de serem dissolvidas e absorvidas. Para uma liberação efetiva do ativo, uns dos critérios relacionados à formulação como a escolha dos excipientes e o tipo de revestimento devem ser considerados. O revestimento com polímeros é utilizado para melhorar a estabilidade do fármaco, mascarar sabor ou para promover a liberação em locais específicos de acordo com a variação do pH. A técnica considerada como “padrão ouro” para monitorar FFS no trato gastrintestinal do homem é a cintilografia, entretanto, métodos alternativos com base na detecção de campo magnético merecem destaque. A técnica de Biosusceptometria de Corrente Alternada (BAC) tem evoluído, apresentando como vantagem ser um método não-invasivo e livre de radiação ionizante. A BAC utiliza bobinas de indução para registrar a variação temporal do fluxo magnético a partir da resposta de um material magnético ingerido, aplicando-se um campo magnético alternado no meio biológico. O objetivo deste estudo é empregar a BAC para avaliar in vitro a influência de três diferentes polímeros de revestimento em diversos parâmetros farmacotécnicos e no processo de desintegração de comprimidos
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The capacitor-commutated converter (CCC) has frequently been used in the conception of HVDC systems connected to busbars with low short circuit level. This alternative arrangement, in substitution to the conventional ones, guarantees less sensitive operational conditions to problems related with the commutation failure in the inverters besides supplying part of the reactive energy to be compensated. Studies related with its performance in steady and transient states have been presented in several works, however its behavior as harmonic source is still little explored. This work presents preliminary studies focusing the generation of characteristic harmonics by this type of converter. Subjects related with the amplification of the harmonic magnitudes are investigated and compared considering similar arrangements of conventional static converters (LCC) and CCC schemes. It is also analyzed the harmonic generation on the dc side of the installation and its influence on the ac side harmonics. The results are obtained from simulations in the time domain in PSpice environment and they clearly illustrate the operational differences between the L CC and the CCC schemes with regard to characteristic harmonic generation.
Resumo:
This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.
Resumo:
A combinatorial mathematical model in tandem with a metaheuristic technique for solving transmission network expansion planning (TNEP) using an AC model associated with reactive power planning (RPP) is presented in this paper. AC-TNEP is handled through a prior DC model while additional lines as well as VAr-plants are used as reinforcements to cope with real network requirements. The solution of the reinforcement stage can be obtained by assuming all reactive demands are supplied locally to achieve a solution for AC-TNEP and by neglecting the local reactive sources, a reactive power planning (RPP) will be managed to find the minimum required reactive power sources. Binary GA as well as a real genetic algorithm (RCA) are employed as metaheuristic optimization techniques for solving this combinatorial TNEP as well as the RPP problem. High quality results related with lower investment costs through case studies on test systems show the usefulness of the proposal when working directly with the AC model in transmission network expansion planning, instead of relaxed models. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The AC electric field and temperature dependences of the dielectric permittivity for strontium barium niobate (Sr(0.75)Ba(0.25)Nb(2)O(6)) relaxor ferroelectric thin films have been investigated. The results indicate the existence of a true mesoscopic structure evidenced by the nonlinear dielectric response of these films, which is similar to those observed for bulk relaxor ferroelectrics. A tendency for a temperature dependent crossover from a linear to a quadratic behaviour of the dielectric nonlinearity was observed, indicating an evolution from paraelectric to glass-like behaviour on cooling the samples towards the freezing temperature transition.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)