94 resultados para AFT Models for Crash Duration Survival Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and rapid method was developed for the determination of amfepramone hydrochloride, fenprorex, and diazepam in capsules using high performance liquid chromatography (HPLC) with UV detection. This procedure provided conditions for the separation of the active ingredient from the complex matrices of the dosage forms by extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (50:10:40) as a mobile phase, LiChrospher 100 RP 18 column (125 x 5 mm id, 5 mu m), a column temperature of 25 +/- 1 degrees C and detection at 230 nm.The calibration curves were linear over a wide concentration range (20-2000 mu g.mL(-1) to amfepramone hydrochloride, 8-800 mu g.mL(-1) to fenproporex, and 4-200 mu g.mL(-1) to diazepam) and good analytical recovery (87.1 to 107.8%) was obtained. The method is accurate and precise, as well as having advantages such as simplicity and short duration of analysis. Twenty samples of pharmaceutical preparations labelled as natural products were analysed. Anorectics and diazepam, were detected in 40% of the samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relaxed conditions for stability of nonlinear continuous-time systems given by fuzzy models axe presented. A theoretical analysis shows that the proposed method provides better or at least the same results of the methods presented in the literature. Digital simulations exemplify this fact. This result is also used for fuzzy regulators design. The nonlinear systems are represented by fuzzy models proposed by Takagi and Sugeno. The stability analysis and the design of controllers axe described by LMIs (Linear Matrix Inequalities), that can be solved efficiently using convex programming techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Relaxed conditions for stability of nonlinear, continuous and discrete-time systems given by fuzzy models are presented. A theoretical analysis shows that the proposed methods provide better or at least the same results of the methods presented in the literature. Numerical results exemplify this fact. These results are also used for fuzzy regulators and observers designs. The nonlinear systems are represented by fuzzy models proposed by Takagi and Sugeno. The stability analysis and the design of controllers are described by linear matrix inequalities, that can be solved efficiently using convex programming techniques. The specification of the decay rate, constrains on control input and output are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize articular and systemic inflammatory activity in juvenile idiopathic arthritis (JIA), identifying remission status with and without medication.Methods: A total of 165 JIA cases, followed for a mean period of 3.6 years, were reviewed in order to characterize episodes of inactivity and clinical remission on and off medication. The resulting data were analyzed by means of descriptive statistics, survival analysis, by comparison of Kaplan-Meier curves, log rank testing and binary logistic regression;analysis in order to identify predictive factors for remission or persistent activity.Results: One hundred and eight of the cases reviewed fulfilled the inclusion criteria: 57 patients (52.7%) exhibited a total of 71 episodes of inactivity, with a mean of 2.9 years per episode; 36 inactivity episodes (50.7%) resulted in clinical remission off medication, 35% of which were of the persistent oligoarticular subtype. The probability of clinical remission on medication over 2 years was 81, 82, 97 and 83% for cases of persistent oligoarticular, extended oligoarticular, polyarticular and systemicJIA, respectively. The probability of clinical remission off medication 5 years after onset of remission was 40 and 67% for patients with persistent oligoarticular and systemic JIA, respectively. Persistent disease activity was significantly associated with the use of an anti-rheumatic drug combination. Age at JIA onset was the only factor that predicted clinical remission (p = 0.002).Conclusions: In this cohort, the probability of JIA progressing to clinical remission was greater for the persistent oligoarticular and systemic subtypes, when compared with polyarticular cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the adherence of participants in a program of physical activity; and to verify if there is any association between the age, Body Mass Index and General Functional Fitness Index with this adherence. It was used the control of frequency for 62 months and data of the anthropometric and functional evaluations of 122 participants (58 + 9 years). 49.2% of the participants gave the program up and 50.8% remained to it. The average of permanence time was 24 + 17 months. The percentage of the adherence of people with satisfactory fitness is greater than with not satisfactory fitness. The percentage of adherence of older people is larger than younger age. The percentage of adherence of not-obese is greater than of obese. However, none of these variables presented statistical difference. It can be concluded that even though there was adherence with similar results even to permanence as to desistance, the time of permanence in the program was very high when compared to other studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are no previous studies on the comparative virulence of Candida dubliniensis with other non-albicans species. The aim of this study was to compare the virulence and infection kinetics of C. dubliniensis and other species. Candida albicans, C. dubliniensis, Candida tropicalis and Candida krusei (reference strains) were inoculated intravenously in mice. For infection kinetics evaluation, a group of five animals were sacrificed after 6 h, 3, 7, 14 and 21 days. Microbiological evaluations (liver, spleen, kidneys, lungs and brain) and histopathological examination of the kidney were performed. The results of virulence evaluation were analysed using Kaplan-Meier survival analysis (5%). Candida dubliniensis-inoculated mice survived for longer periods compared with those with C. albicans (P = 0.005). No differences were detected in relation to C. tropicalis (P = 0.326) and C. krusei (P = 0.317). Most of the organs were persistently colonised by C. albicans and C. dubliniensis even by day 21. Tendency of C. krusei clearance was observed in all organs. Fungal masses and renal lesions were observed after inoculation of C. albicans, C. dubliniensis and C. tropicalis. Within the limits of the study, data on survival rate and dissemination capacity suggest that C. dubliniensis is less virulent than C. albicans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)