548 resultados para Radiação


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nuclear medicine uses non-sealed sources for exams and treatments, because the movement of these sources, source of patients injected or not, involve a wide range of environmental radiometric levels. To better control of these levels this study was aimed at monitoring points strategically distributed in all environments Sector Technical Nuclear Medicine, Hospital of the Botucatu Medical School, performing two measurements at random times daily for a period of three months, sampling the normal routine of the sector. The detector Geiger-Muller was used for the acquisition of exposure rates of the points, efficiency and reprodutibility test have shown good performance of this equipment for this purpose. The results allowed to make a projection of annual dose for each environment indicating higher risks for Occupationally Exposed Individuals as well as Public Individuals compared with the limits established by the National Commission of Nuclear Energy. Was developed a spatial map of dose that can be used as a visual warning to the regions with the highest exposure to ionizing radiation, enabling reduced risk of a potential exposure

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In radiotherapy, computational systems are used for radiation dose determination in the treatment’s volume and radiometric parameters quality analysis of equipment and field irradiated. Due to the increasing technological advancement, several research has been performed in brachytherapy for different computational algorithms development which may be incorporated to treatment planning systems, providing greater accuracy and confidence in the dose calculation. Informatics and information technology fields undergo constant updating and refinement, allowing the use Monte Carlo Method to simulate brachytherapy source dose distribution. The methodology formalization employed to dosimetric analysis is based mainly in the American Association of Physicists in Medicine (AAPM) studies, by Task Group nº 43 (TG-43) and protocols aimed at dosimetry of these radiation sources types. This work aims to analyze the feasibility of using the MCNP-5C (Monte Carlo N-Particle) code to obtain radiometric parameters of brachytherapy sources and so to study the radiation dose variation in the treatment planning. Simulations were performed for the radiation dose variation in the source plan and determined the dosimetric parameters required by TG-43 formalism for the characterization of the two high dose rate iridium-192 sources. The calculated values were compared with the presents in the literature, which were obtained with different Monte Carlo simulations codes. The results showed excellent consistency with the compared codes, enhancing MCNP-5C code the capacity and viability in the sources dosimetry employed in HDR brachytherapy. The method employed may suggest a possible incorporation of this code in the treatment planning systems provided by manufactures together with the equipment, since besides reducing acquisition cost, it can also make the used computational routines more comprehensive, facilitating the brachytherapy ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since its discovery, radioactivity has brought numerous benefits to human societies. It has many applications in medicine, serving as a tool for non-invasive methods for diagnosis and therapies against diseases such as cancer. It also applies to technologies for energy in nuclear power plants with relatively low impacts on terms of perfect security. All applications, however, have risks, requiring maximum caution to drive processes and operations involving radioactive elements because, once released into the environment, they have extremely harmful effects on organisms affected. This paper presents fundamental concepts and principles of nuclear physics in order to understand the effects of radioactive elements released into the environment, culminating on the issue of radioactive contamination. Literature review allowed us to understand the radioactive contamination problem on living beings. Three major nuclear accidents have happened in the last thirty years, two of them in consecutive years. The nuclear accident at Chernobyl, Ukraine, in 1986, polluted large areas, condemning hundreds of thousands of people to live with consequences of the accident and effects of radiation, killing thousands of people throughout the years. In 1987, a major radiological accident occurred in Goiania (GO) when a source of radioactive cesium was violated, leading to the death of those who had direct or indirect contact with cesium. The most recent accident, in March, 2011, was located at the nuclear power plant in Fukushima Prefecture, Japan, after an earthquake and tsunami hit the region. There is no extensive and accurate knowledge about the consequences of the contamination entailed in that accident, although it is possible to verify signals on a global scale. An analysis of reports of contamination of large areas generated by nuclear plants with release of hazardous wastes suggests it is necessary to rethink the energy matrix of the various countries...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Triacrylate resins are widely used to fabricate 3D microstructures, photonic crystals and optical devices. These resins can be doped with photosensitive materials like Disperse Red 1 (DR1), an Azo dye that changes its molecular configuration from trans to cis (photoisomerisation) with variations in their optical absorption spectrum when irradiated with ultraviolet or visible light. The reversibility of this process is thermally activated and occurs when the molecule remains at dark. In this work was prepared a 1:1 mixture of ethoxylated-6-trimethylolpropane (SR499) and tris-2-hydroxyethyl-isocyanurate (SR368) triacrylate resins, plus photoinitiator Lucirin TPOL, forming a UV curable polymeric matrix doped with DR1. Thin films were deposited onto glass slides by spin-coating technique. The films showed photochromic effect when illuminated with a low power diode laser (450 nm and 50mW/cm2). This effect is reversible after sample is left in dark. Thermochromic effect was evaluated by optical absorption measurements in the range of 40 to 140oC, heating the samples in-situ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Dosímetria Termoluminescente (TLD) é uma ferramenta extremamente versátil para a avaliação da dose absorvida por tecidos humanos, devido à interação dos mesmos com a radiação ionizante. As características termoluminescentes (TL) do fluoreto de lítio (LiF) foram estudadas extensivamente primeiramente por apresentar número atômico muito próximo ao do tecido humano e, portanto, conseguir quantificar com fidelidade a radiação recebida na ordem de μGy (micro Gray) a kGy (kilo Gray) . Foram abordados os princípios físicos envolvido no procedimento de calibração e tratamento dos dosímetros (total de 224 pastilhas), os quais foram separados, após tratamento, em 75 grupos. Este trabalho foi de suma importância na aplicação dos conceitos físicos abordados durante a formação da graduação no curso de Bacharelado em Física Médica, e pode auxiliar em projetos, em andamento, junto ao grupo de pesquisa de Física Aplicada ao Radiodiagnóstico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, it is presented a novel method for calculating some intrinsic parameters such as capture mean time, thermic emission mean time, capture probability and noise gain on quantum well infrared photodetectors. Such devices are built by depositing layers of semiconductors of different energy gap, forming quantum wells. The present method uses rate equations to describe the occupation of discrete states of the quantum wells, that together with noise gain equations given in literature, are solved self consistently. The input data of the method is experimental measurement of dark current (current measured with no relevant incident photon) versus applied bias. In order to validate this approach, the values obtained were compared with results from literature

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Induction heating is a process closely linked to the concepts of heat transfer. It also covers electromagnetic induction and effect of film. Many companies use this technology in their processes due to the high accuracy that can be obtained at temperatures induced. However the dominance of this technology is not common among Brazilian industries. This involves complex systems of equation and heat exchange in transient conduction, and convection and radiation losses. With this work we seek the ability to analyze which parameters influence over this process and the order of magnitude of time required for heating a cylindrical part

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we discussed the possibility of installing a photovoltaic panel in a house in order to reduce electrical consumption. Brazil is a country with a huge solar resource and photovoltaic technology allows transforming solar energy into electricity, helping to decentralize energy production. To enlarge the field of view, the study compares with the equivalent in a Spanish city, discussing how the law favors the initiative of using this type of energy. It will be seen that, with the encouragement of the government, the project can be done because the installation is amortized over a reasonable period of time, about eight years in Spain and three in Brazil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ao administrar um fármaco, devem ser considerados fatores como a forma farmacêutica apropriada, a via de administração com maior eficiência e o que será mais bem aceita pelo paciente. Formas farmacêuticas sólidas (FFS), tais como comprimidos, representam a principal escolha, pois são fáceis de preparar, armazenar, transportar e são bem aceitas pelos pacientes. Porém, a absorção dos fármacos administrados em comprimidos depende do processo de desintegração, ou seja, um processo tempo-dependente que ocorre sob a ação de um desintegrante que promove a fragmentação da forma farmacêutica em partículas passíveis de serem dissolvidas e absorvidas. Para uma liberação efetiva do ativo, uns dos critérios relacionados à formulação como a escolha dos excipientes e o tipo de revestimento devem ser considerados. O revestimento com polímeros é utilizado para melhorar a estabilidade do fármaco, mascarar sabor ou para promover a liberação em locais específicos de acordo com a variação do pH. A técnica considerada como “padrão ouro” para monitorar FFS no trato gastrintestinal do homem é a cintilografia, entretanto, métodos alternativos com base na detecção de campo magnético merecem destaque. A técnica de Biosusceptometria de Corrente Alternada (BAC) tem evoluído, apresentando como vantagem ser um método não-invasivo e livre de radiação ionizante. A BAC utiliza bobinas de indução para registrar a variação temporal do fluxo magnético a partir da resposta de um material magnético ingerido, aplicando-se um campo magnético alternado no meio biológico. O objetivo deste estudo é empregar a BAC para avaliar in vitro a influência de três diferentes polímeros de revestimento em diversos parâmetros farmacotécnicos e no processo de desintegração de comprimidos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiotherapy is a branch of medical physics related to the treatment of malignant neoplasm, being an important instrument in the fight against cancer, when combined with the effort of a multidisciplinary team, composed of, physicians, physicists, nurses and technicians. Every year more than 3.5 million new cases of cancer are recorded in the world, being the prostate cancer responsible for approximately 25% of this amount (INCA and IARC, 2008). In this type of cancer, radiotherapy is a method indicated for treatement. The technological advance in this area over years has allowed a greater accuracy in the tumor location, more conformation of the radiation beam around the tumor, reducing the dose in healthy tissues and a consequent dose increase on treatment (Bedford et al., 1999). A radiotherapy planning, in which the physicist develops an important role, is composed of several steps, including choosing the best configuration of treatment beams. This choice has a close relationship with success of therapy and is critical to achieve the best distribution of dose inside the tumor and expose the least as possible the healthy tissue to radiation. In this work, two options for setting up camps in the first phase in a treatment of prostate cancer were simulated in computer planning: 4 fields orthogonal or “Box” with gantry angles in 00, 1800, 2700 e 90° and 4 fields angled or “X” (1350, 450, 3150 e 2250). The percentage of the rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5% respectively (Greco et al., 2003). The femoral toxicity have limited dose by 70% of the total dose prescribed in a prostate treatment (Bedford et al., 1999). The planning of 27 patients with prostate adenocarcinoma submitted to 3D conformal radiotherapy were accompanied. As a result, it was assessed that the best TCP (tumor control probability)... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho propõe rotinas computacionais usando o Método de Monte Carlo com o Código MCNP-5, para analisar os perfis de dose de radiação liberada nos tratamentos de tumores de pele e otimizar os cálculos radiométricos dos feixes de radiação estudados. Foram realizadas medidas dosimétricas do feixe de radiação, comparando os resultados obtidos com os respectivos valores fornecidos pelo serviço de física médica das instituições, com resultados informados pelo fabricante do equipamento e com as simulações computacionais efetuadas com o Código MCNP-5. A quantificação dos erros relativos percentual entre os resultados simulados e os fornecidos pelo Serviço de Radioterapia (E1), os informados pelo fabricante (E2) e os medidos experimentalmente (E3) são inferiores a 4,0% e validam a metodologia computacional proposta para avaliação do comportamento do feixe de raios-X superficial e do feixe de raios γ da unidade de Cobaltoterapia. A metodologia de análise do espectro energético e da curva de porcentagem de dose profunda (PDP) desenvolvida neste trabalho pode ser estendida para estudos de outros feixes clínicos e subsidiar os dados radiométricos utilizados nos planejamentos e cálculos de dose realizados pelo profissional da física médica na sua rotina nos Serviços de Radioterapia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose