468 resultados para Exodontia de molares
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Since bleaching has become a popular procedure, the effect of peroxides on dental hard tissues is of great interest in research. Purpose: The aim of this in vitro study was to perform a qualitative analysis of the human enamel after the application of in-office bleaching agents, using Scanning Electron Microscopy (SEM). Materials and Methods: Twenty intact human third molars extracted for orthodontic reasons were randomly divided into four groups (n=5) treated as follows: G1- storage in artificial saliva (control group); G2- four 30-minute applications of 35% carbamide peroxide (total exposure: 2h); G3- four 2-hour exposures to 35% carbamide peroxide (total exposure: 8h); G4- two applications of 35% hydrogen peroxide, which was light-activated with halogen lamp at 700mW/cm2 during 7min and remained in contact with enamel for 20min (total exposure: 40min). All bleaching treatments adopted in this study followed the application protocols advised by manufacturers. Evaluation of groups submitted to 35% carbamide peroxide was carried out after two time intervals (30 minutes and 2 hours per session), following the extreme situations recommended by the manufacturer. Specimens were prepared for SEM analysis performing gold sputter coating under vacuum and were examined using 15kV at 500x and 2000x magnification. Results: Morphological alterations on the enamel surface were similarly detected after bleaching with either 35% carbamide peroxide or 35% hydrogen peroxide. Surface porosities were characteristic of an erosive process that took place on human enamel. Depression areas, including the formation of craters, and exposure of enamel rods could also be detected. Conclusion: Bleaching effects on enamel morphology were randomly distributed throughout enamel surface and various degrees of enamel damage could be noticed. Clinical significance: In-office bleaching materials may adversely affect enamel morphology and therefore should be used with caution.
Resumo:
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The author has verified the average depth of the mandibular fossa, in the X-ray image, using the oblique lateral transcranial technique from the right and left sides samples of each patient, which included a total of 176 patients, 87 male and 89 female. The patients were in following phases: deciduous dentítion (the patients had only deciduous teeth in the oral cavity or, if they had any permanent teeth, they could not be in occlusion), mixed dentition (the patients presented deciduous and permanent in the oral cavity) and permanent dentition (the patients had only permanent teeth in the oral cavity), until the eruption of the permanent third molars, in the region from São José dos Campos. São Paulo. Brazil. The patients were under treatment at the Dental School. UNESP (São Paulo State University). ln order to measure the depth of the mandibular fossa in millimeters an imaginary line was traced on the X-ray image, perpendicular to the other line that served as a reference, which was traced from the botton part of the articular eminence up to the tympanosquamous fissure. After the data were obtained and put in a data sheet, they underwent statistical analysis. The results showed that, in the average, the depth of the mandibular fossa in masculine sex is non-statistically signíficant larger than what was observed in feminíne sex, and the right side is larger than the left side, with significant statistical differences. However, only in permanent dentition, in masculine sex, the depth of the mandibular fossa on the right side is larger than on the left side with significant statistical differences
Resumo:
The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the mean of alveolar bone loss (%) in radiographies of patients referred to specialist for periodontal treatment. Full mouth series of periapical radiographies (paralelism technique) were used. A total of 9808 proximal surfaces in 4804 teeth of 213 patients (90 males and 123 females), mean age, 44.3 years, were assessed. The alveolar bone loss was measured in relation to root lenght expressed as an average similar to Schei 's technique (1959) without the use of ruler. The references used were the distances cement-enamel juntion (CEJ) - alveolar crest (AC) and CEJ- dental apex taken with a digimatic caliper. The results showed that the mean values of alveolar bone loss (%ABL) was 22.39%. Men showed higher mean values of %ABL than women; the %ABL increased with the age, but the difference among age groups was no statistical significant (p>0.05); the mean values of %ABL of distal surfaces was higher than mesial surfaces (p<0.01), ríght quadrants exhibited higher %ABL values than left quadrants (p<0.01); maxillary sites showed mean values of %ABL higher than mandibular sites; the highest mean values of %ABL was found in molar group, followed by incisor groups, and premolar group; the canine group exhibited lower mean values of %ABL; the differences among the groups was considered statitistically significant (p<0.01). lt was suggested the usage of this technique in the dentistry offices and radiological services for the patient 's documentation and assortment and for later comparison about alveolar bone level
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
This work shows the preparation and characterization of the new nanocomposites based on fibroin and biocellulose. Bacterial cellulose (BC) is an exopolysaccharide produced by bacteria of the genus Gluconacetobacter, which it has identical chemical structure of the cellulose from plants and it has gained attention in the field of research for its unique properties as excellent mechanical properties when dry and hydrated , higher capacity of water retention, moldability , biodegradability and excellent biological affinity . Silk fibroin (SF) is a structural protein present in the cocoon of the silkworm, Bombyx mori, has been identified as suitable for developing optical devices, tissue engineering application, enzyme immobilization, controlled release drug agent biopolymer. Silk fibroin/bacterial cellulose nanocomposite films were prepared impregnating different cellulose charges (0.5 %, 1.0 %, 1.5 %, 2.5 %, 5.0 % and 10.0 %) weight/weight. According mechanical tests and water and Paynes's cup permeability showed that SF/BC 1% nanocomposite has the most relevant results. Poliethylenoglicol (PEG) containing SF films improved optical and mechanical properties when compared to pristine SF film. New SF/BC nanocomposites could be applied in Medicine, as biodegradable packaging and flexible substrates for OLEDs.