436 resultados para radiographic apex


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims the evaluation of the radiation dose levels involved in veterinary radiology and to contribute to review the procedures for performing radiographic exams in animals in the Department of Veterinary Radiology of Faculdade de Medicina Veterinária e Zootecnia of Universidade Estadual Paulista (FMVZ-UNESP/Brazil). The obtained results has shown to be extremely important the assessment of doses involved in veterinary diagnostic radiology procedures both to protect the occupationally exposed workers and to optimize the delivered doses to the animals. © 2009 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 ± 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 ± 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the apical leakage of roots filled by three different gutta-percha techniques: lateral condensation, Tagger's hybrid and E&Q Master. Forty-two extracted single-rooted teeth were used. The coronal part of each tooth was removed and the root received biomechanical preparation using a 60-K file. The roots were randomly divided into three groups according to the technique of filling the root canal: Group I, lateral condensation; Group II, Tagger's hybrid; Group III, E&Q Master. The roots were submitted to dye leakage test with Rhodamine B for 7 days, using vacuum during the initial 30 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. Statistical analysis indicated that lateral condensation and E&Q Master techniques showed lower leakage than Tagger's technique (P = 0.0016). However, statistically no difference was found between lateral condensation and E&Q Master system techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Bone strength is influenced by a number of different determinants, such as mass, size, geometry and also by the intrinsic material properties of the tissue. Aims: The structure and mechanical properties of the femur were analyzed in aged (14 mo-old) animals submitted to hindlimb unloading (HU) for 21 days. Methods: Twenty Wistar rats were randomly divided into Control and HU groups and the femur was submitted to dual X ray absorptiometry (DXA), DIGORA radiographic density, mechanical compression testing and Knoop microhardness analyse in cortical and cancellous bone. Results: Femurs from HU group presented significantly lower failure load, decreased bone mineral density (BMD)/bone mineral content (BMC) in whole bone; proximal/distal epiphysis and middiaphyseal cortical bone measured by DXA were similar in the two groups; radiographic density from areas in proximal epiphysis was significantly lower in HU group, and microhardness measured at periosteal and endosteal levels were also signifcantly diminished in HU compared with Control group. Conclusion: Disuse induced damage in the trabecular femoral bone architecture with decisive effect on the head and trochanteric fossa, which became weaker. Bone diaphyseal cortical hardness also suffered effect of unloading, probably related to osteocyte/osteoblast activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the 9-year clinical outcome of the two-stage surgical rehabilitation of a severely atrophic edentulous maxilla with a metal-resin fixed denture supported by implants anchored in the zygomatic bone and the maxilla. After clinical and radiographic examination, zygomatic implants were inserted bilaterally and four standard implants were placed in the anterior region of the maxilla. Six months later, the implants were loaded with a provisional acrylic resin denture, and the definitive implant-supported metal-resin fixed denture was provided 1 year after implant placement. After 9 years of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. In the present case, the rehabilitation of severe maxillary atrophy using the zygomatic bone as a site for implant anchorage provided good long-term functional and esthetic results. Therefore, with proper case selection, correct indication, and knowledge of the surgical technique, the use of zygomatic implants associated with standard implants offers advantages in the rehabilitation of severely resorbed maxillae, especially in areas with inadequate bone quality and volume, without needing an additional bone grafting surgery, thereby shortening or avoiding hospital stay and reducing surgical morbidity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conventional radiography, using industrial radiographic films, has its days numbered. Digital radiography, recently, has taken its place in various segments of products and services, such as medicine, aerospace, security, automotive, etc. As well as the technological trend, the digital technique has brought proven benefits in terms of productivity, sensitivity, the environment, tools for image treatment, cost reductions, etc. If the weld to be inspected is on a serried product, such as, for example, a pipe, the best option for the use of digital radiography is the plane detector, since its use can reduce the length of the inspection cycle due to its high degree of automation. This work tested welded joints produced with the submerged arc process, which were specially prepared in such a way that it shows small artificial cracks, which served as the basis forcomparing the sensitivity levels of the techniques involved. After carrying out the various experiments, the digital meth odshowed the highest sensitivity for the image quality indicator (IQI) of the wire and also in terms of detecting small discontinuities, indicating that the use of digital radiography using the plane detector had advantages over the conventional technique (Moreira et al. Digital radiography, the use of plane detectors for the inspection of welds in oil pipes and gas pipes.9th COTEQ and XXV National Testing Congress for Non Destructive Testing and Inspection; Salvador, Bahia, Brazil and Bavendiek et al. New digital radiography procedure exceeds film sensitivity considerably in aerospace applications. ECNDT; 2006; Berlin). The works were carried out on the basis of the specifications for oil and gas pipelines, API 5L 2004 edition (American Petroleum Institute. API 5L: specification for line pipe. 4th ed. p. 155; 2004) and ISO 3183 2007 edition (International Organization for Standardization, ISO 3183. Petroleum and gas industries - steel pipes for pi pelines transportation systems. p. 143; 2007). © 2010 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of the type of rotary cutting instrument on bone repair after osteotomy in swine jaw, was evaluated using digital and densitometric radiographic examinations, at controlled times. Two cross-sectional dissections were made through the base of the right jaw, one using a high speed rotary instrument and the other using low speed, both with liquid cooling. After established periods the animals were sacrificed and their jaws removed for direct and indirect digital radiographic and densitometric studies using the CROMOX, DIGORA and ODR systems. In the initial periods (7 and 28 days) the bone density was higher in osteotomy areas performed with high rotation speeds, and in the final periods (60 and 90 days) the bone density was higher in the osteotomies performed with low rotation, indicating a better final bone repair with the use of low rotation. The qualitative analysis of the repair process was made by the ODR system which obtained three-dimensional and coloured digital images, which enable the bone thickness to be measured using an aluminium wedge. This showed that by twenty-eight days the bone repair was already apparently complete. © 2010 SECOM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill), and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To assess the bone mineral density on conventional and digitized images, comparing whether different parameters of digitization and storage change these values. Methods: Twenty radiographs were taken from five partially dentulous dry mandibles with an aluminum 7-mm stepwedge placed on the superior edge of the film. After processing, the films were digitized with a resolution of 600 and 2,400 d.p.i. and saved as TIFF and JPEG files. On every conventional and digitized image, circular regions of interest were selected for densitometry and radiographic contrast analysis. Results: Pearson's correlation coefficient showed a significant and strong mean gray values association between digitized and conventional images, differing from radiographic contrast that did not show a significant association. ANOVA did not reveal a statistically significant difference in bone density and radiographic contrast among the four digitized image groups, but the conventional image contrast was significantly lower. Conclusions: Bone mineral density did not differ in both conventional and digitized images. The parameters of image compression and resolution, tested in this study, did not change the results of densitometry and digitization process increased the radiographic contrast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Developmental disturbances of permanent teeth can result from trauma to primary teeth because of the proximity of the root of the primary teeth to their permanent successors. We describe the case of a 14-month-old boy who was referred to the baby clinic of the School of Dentistry, Universidad Estadual Paulista, Araçatuba, Brazil, after sustaining a severe trauma that led to intrusion of the right primary central incisor. Radiographic examination 4 years after the trauma showed a developing morphological change in the germ of the permanent successor. On eruption of the permanent central incisor, a crown malformation along with enamel hypoplasia was observed. We concludethat radiographic follow-up is indicated after trauma to monitor possible sequelae in the permanent successors even before their eruption. © 2011 Canadian Dental Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the radiographs alteration of the castor oil bean polymer applied for the filing of induced bone fault in horses. Five animals were evaluated, subjected to a local anesthesia and sedation, proceeding to a surgical induction of a hole in the radio bone, in both members with three centimeters depth perforations. It was used a drill of eight millimeters of diameter. The right member served as a control, without filling induced holes. The holes in left radio were filled with the commercial polymer derived from the castor oil bean. We evaluated the localized swelling and radiological aspects as: the establishment of scores for bone filling, sclerosis and a morphometric analysis of the sclerosis area, in 15, 45, 90 and 180 days of lesion evolution. There was more swelling in local members whose injuries were filled with polymer from castor oil bean. By comparison, the radiographic examination showed better bone filling in the gaps of members control. We concluded that the completion of castor oil bean polymer in bone holes induced in radio of horses, delayed the bone healing, in the radiographic evaluation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study aims to review anatomical, clinical, and pathological concepts as well as to discuss the most adequate therapeutic approach to the mucoceles of the glands of Blandin-Nuhn. Discussion: The glands of Blandin-Nuhn are localized in the ventral part of the tongue, next to the apex in the lingual median plane. Development of a mucocele in this site is rarely seen; besides, as the glands of Blandin-Nuhn are not encapsulated and are directly overlapped to the muscle tissues, their manipulation tends to be different from the other oral mucoceles. Conclusion: As Blandin-Nuhn mucoceles are uncommon and their clinical appearance could be similar to other lesions, it is important that health professionals know their clinical and histopathological features to avoid having them misdiagnosed. © 2010 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of all-ceramic systems following metalceramics restorations allowed simulation of natural dentition due to favorable esthetics and resistance. In-Ceram is an alternative when esthetics is primordial as well as resistance required in rehabilitation. However, an ideal smile is associated to not only shape, color, texture and translucency but also harmony with gingival tissue. So, the aim of this study is to report a clinical case based on periodontal and fixed partial dentures principles to perform periodontal plastic surgery followed by esthetic rehabilitation. A female patient, 40-year-old, presented complaint about dental esthetics. After clinical and radiographic exams, metal-ceramics crowns (teeth 11, 12, 13, 21, 22 and 23) were considered unsatisfactory due to marginal leakage, color change in gingival tissue associated to metallic margin, and gummy smile. So, a crown lengthening surgery of anterior teeth was performed followed by rehabilitation of superior teeth with In-Ceram single crowns. Clinical significance: The interaction between periodontics and fixed prosthodontic area is the key of an adequated treatment planning which involves gingival smile to provide function and an esthetic condition in association with an esthetic, resistant and predictable material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Customized glass fiber posts that is well adjusted into the root canal and have mechanical properties similar to those of dentin may be a suitable treatment for severely compromised endodontically treated teeth. This article reports a 3-year follow up of severely damaged endodontically treated teeth restored with unidirectional fiber glass customized post and core system instead of a conventional fiber post. The fabrication of this glass fiber customized post is a simple technique, providing an increased volume of fibers into the root canal, and an adequate polymerization of the post-core system. Over a three-year period, the treatments demonstrated good clinical and radiographic characteristics, with no fracture or loss of the post and/or crown. This technique can be considered effective, less invasive, and suitable for restore endodontically treated teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This article describes a clinical report with a new system for guided surgical treatment and immediate load prosthesis in the flapless surgical technique. Case report: Based on a computed tomography (CT) of a 64 - year-old edentulous patient, the cross sections were reformatted and used to construct a virtual planning of the implants and a guide template in Dental Slice. Six dental implants were placed in the maxilla and mandible using a Slice Guide System. Following a 30-month in maxilla and 24-month in mandible healing period, the clinical and radiographic evaluation and computed tomography (CT) showed good clinical stability. The Slice Guide System proved satisfactory for the Flapless Surgical Technique in dental implants.