545 resultados para Fundição odontológica
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Introduction: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). Material and Method: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. Results and Conclusions: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Biosecurity is currently a concern for all health-related services, including dentistry, since infection control has a relevant importance. In dental practice, health-related occupations have contact with a great number of individuals who are potentially capable to transmit pathogens. This study comprised a descriptive evaluation of the universal precaution measures for infection control adopted by dental practitioners working at public and private offices in the city of Araçatuba, SP. Data collection was performed by a quiz with questions about individual and collective protection equipments. The results showed that the use of caps was reported by 55% of the professionals working at the public sector and 90% for the private sector. The use of masks and gloves was reported by all professionals surveyed; nevertheless, glove change between patients was not reported by 40% of professionals working at the public sector. There were more flaws in public offices as to the use of protective barriers, since except for the use of gloves, gowns and masks, the frequency of use of those barriers was smaller than at private offices.
Resumo:
Objectives: The aim of this study was to evaluate the behavior of the polymer histomorphometrically castor during the healing process of defects of critical size calvarial preparations in rats. Materials and Methods: Twenty animals underwent a surgical procedure that was to be held in the calvaria of each animal a critical defect of 8 mm in diameter with a drill trephine. The rats were divided into two groups according to the following procedures: group C received no treatment and the bone defect site was filled with blood clot, group M, the bone defect was filled with castor oil polymer particles. The animals were sacrificed 180 days after the surgical procedures. After routine laboratory procedures the specimens were subjected to analysis histomorphometric. Results: In groups C the newly formed bone tissue was well developed, with adjacent areas of osteoid matrix rich in osteoblasts, and restricted to the vicinity of the edges of the defect. In animals of group M was observed newly formed lamellar bone tissue restricted to the vicinity of the defect edges and particles of polymer Castor distributed throughout the defect. There was a higher percentage of newly formed bone area was statistically significant in group C compared to animals in group M. Conclusions: Within the limits of this study can conclude that the castor oil polymer is biocompatible and had kept the area during the healing of critical size defects in surgically prepared rat calvariae.
Resumo:
This work aimed to analyze clinically and histologically the allogen bone graft behavior at 6 and 9 months. A leukoderm, female, 55 years old patient sought dental care for oral rehabilitation with dental implants and implant supported fixed prosthesis in the maxilla. Bilateral sinus lifting procedure were performed in a same patient, the analysis were made after 6 and 9 months, respectively. At 6 months, there was lack of a better bone remodeling in the region, associated to the presence of fibrous connective tissue within the collected tissue, showing us that this is not the best stage of tissue maturation to place dental implants. The 9 months period showed an improvement, with a more organized bone tissue surrounding particles of homogenous bone, what possibly had increased implant stability at the time of surgery. There is no doubt about the increase of clinical applications of FFBA, but there are no studies available regarding the standardization of time to load implants inserted in allografts. So papers with long-term monitoring are necessary to eliminate questions that still remain to be answered.
Resumo:
Objectives: The aim of this study was to evaluate the behavior of the polymer histomorphometrically castor during the healing process of defects of critical size calvarial preparations in rats. Materials and Methods: Twenty animals underwent a surgical procedure that was to be held in the calvaria of each animal a critical defect of 8 mm in diameter with a drill trephine. The rats were divided into two groups according to the following procedures: group C received no treatment and the bone defect site was filled with blood clot, group M, the bone defect was filled with castor oil polymer particles. The animals were sacrificed 180 days after the surgical procedures. After routine laboratory procedures the specimens were subjected to analysis histomorphometric. Results: In groups C the newly formed bone tissue was well developed, with adjacent areas of osteoid matrix rich in osteoblasts, and restricted to the vicinity of the edges of the defect. In animals of group M was observed newly formed lamellar bone tissue restricted to the vicinity of the defect edges and particles of polymer Castor distributed throughout the defect. There was a higher percentage of newly formed bone area was statistically significant in group C compared to animals in group M. Conclusions: Within the limits of this study can conclude that the castor oil polymer is biocompatible and had kept the area during the healing of critical size defects in surgically prepared rat calvariae