444 resultados para Dental Pulp Necrosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in vitro study assessed the effect of an experimental 4%TiF4 varnish on enamel erosion.Methods: Sixty bovine enamel blocks were randomly allocated to each type of varnish:Duraphat((R)) -D (NaF, 2.26%F), Duofluorid((R))-F(NaF, 2.71% F), TiF4-T(2.45%F) and no-fluoride-P. After application of the varnishes, the blocks were subjected to six sequential pH cycles (cola drink for 10 min and artificial saliva for 50 min, each) per day, during 4 days. After the pH cycles, the blocks were maintained in artificial saliva for 18 h. Enamel alterations were determined in the 2nd and 4th days, using profilometry (wear) and microhardness (%SMHC) tests. Data were tested using ANOVA and Tukey's tests (p < 0.05).Results: the mean %SMHC (+/- S.D.) at the 2nd and 4th day was, respectively, D (-77.26 +/- 5.04(a) and -88.59 +/- 5.11(A)), F (-76.79 +/- 7.82(a) and -88.78 +/- 6.10(A)), T(-88.28 +/- 3.19(b) and -92.04 +/- 2.54(A,B)) and P (-87.96 +/- 2.23(b) and -94.15 +/- 1.14(B)). The mean wear (mu m +/- S.D.) at the 2nd and 4th day was, respectively, D (3.16 +/- 0.32(a) and 7.56 +/- 0.90(A)), F(3.35 +/- 0.78(a,b) and 7.92 +/- 0.98(A)), T (3.81 +/- 0.43(b) and 7.69 +/- 0.76(A)) and P (3.43 +/- 1.13(a,b) and 7.31 +/- 0.53(A)).Conclusions: the NaF varnishes reduced the softening, but had no effect on the reduction of the wear. The TiF4 varnish was not able to reduce the softening and wear. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium alloys are hoped to be used much more for applications as implant materials in the medical and dental fields because of their basic properties, such as biocompatibility, corrosion resistance and specific strength compared with other metallic implant materials. Thus, the Ti-6Al-7Nb alloy that has recently been developed for biomedical use, that is, primarily developed for orthopaedic use, is to be studied in this paper, for application in dental implants. The biocompatibility test in vivo was carried out in dogs and the osseointegration was verified through histological analysis of the samples of the Ti-6Al-7Nb alloy with and without hydroxyapatite coating that were inserted in the alveoli. Within the controlled conditions the samples did not show any toxic effects on the cells. (C) 2001 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyze crown fractures and crown-root fractures due to dentoalveolar trauma, treated in the Integrated Clinic comprehensive dental care at Aracatuba School of Dentistry (UNESP), from January 1992 to July 2002. The data were obtained from files of trauma cases. on the analysis period, 293 patients had crown fractures or crown-root fractures, in 605 teeth. Sixty-nine percent were males and 31% were females. Adolescents between 11 and 18 years old were the most prevalent group (41.6%) and the maxillary arch was the most commonly traumatized (83%). The most commonly affected tooth was the maxillary central incisor (58.3%). The most frequent causes were falls from bicycles (30.8%). It was concluded that the reality of the local service is similar to the published data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness of one resin cement (dual-cure mode or light-cure mode) when illuminated directly or through restorative materials-ceramic (HeraCeram) or composite (Artglass)-by two light curing units. Light curing was carried out using a conventional quartz tungsten halogen (QTH) light source (XL2500) for 40 s, and a light emitting diodes (LED) light source (Ultrablue Is) for 40 s. Bovine incisors had their buccal faces flattened and hybridised. on these surfaces, a mould was seated and filled with cement. A disc of the veneering material (1.5 mm thickness) was positioned over this set for light curing. After storage (24 h/37 degrees C), samples (n = 10) were sectioned for hardness (KHN) measurements. Data were submitted to ANOVA and to Tukey's test (alpha = 0.05). In general, light curing with LED resulted in higher hardness values than QTH. Distinct cement behaviour was observed with different veneering material in association with different light curing units (LCUs). (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their excellent aesthetics, photopolymers have been extensively used in several dentistry applications. However, several problems are reported, e.g. low mechanical and abrasion resistance, shrinkage during polymerization, etc. Properties of the final restorations are intrinsically related to the polymerization stage, which can be conveniently studied by photocalorimetry. In the present work the polymerization reaction and the filler content of different photocurable commercial dental methacrylate-based composites were studied by means of photocalorimetry and thermogravimetry, respectively. The results show that the values of curing rate, the heat of polymerization and the filler content vary significantly from one composite to another.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This in situ blind crossover study investigated the effect of calcium (Ca) rinse prior to the use fluoride (F) dentifrice on remineralisation of artificially demineralised enamel and on the composition of biofilm. Design: During four phases of 14 days, 10 volunteers wore appliances containing two artificially demineralised bovine enamel blocks. Three times a day, they rinsed with 10 mL, of Ca (150 mM) or placebo rinse (1 min). A slurry (1:3, w/v) of F (1030 ppm) or placebo dentifrice was dripped onto the blocks. During I min, the volunteers brushed their teeth with the respective dentifrice. The appliance was replaced into the mouth and the volunteers rinsed with water. The biofilm formed on the blocks was analysed for F and Ca. Enamel alterations were evaluated by the percentage of surface microhardness change (%SMHC), cross-sectional microhardness (% mineral volume) and alkali-soluble F analysis. Data were analysed by ANOVA (p < 0.05). Results: the use of the Ca pre-rinse before the F dentifrice produced a six- and four-fold increase in biofilm F and Ca concentrations, respectively. For enamel, the remineralisation was significantly improved by the Ca pre-rinse when compared to the other treatments. There was a significantly higher concentration of alkali-soluble F in enamel when the F dentifrice was used, but the Ca pre-rinse did not have any significant additive effect. Conclusions: According to our protocol, the Ca pre-rinse significantly increased biofilm F concentration and, regardless the use of F dentifrice, significantly enhanced the remineralisation of artificially demineralised enamel. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By means of IR spectroscopy, we determined the teeth ablation mechanism by an Er:YAG laser oscillating at 2.94 mum. Ejected dental material, ablated by the laser from human teeth, was deposited on an IR window and the absorption spectra were measured in the range 2500-20,000 nm. Sound teeth were used, and the corresponding film spectra were compared to spectra obtained by traditional methods. The films spectra obtained do not differ appreciably from those obtained by the traditional method for sound teeth, indicating that the material ejected by an Er:YAG represents the tooth condition.The obtained results confirm that a spectroscopic analysis of a tooth treated with an Er:YAG laser can be done measuring the absorbance of a film composed of ejected material without the need to slice it. In addition, we could determine that the laser absorption occurs mainly by the interstitial water, and the temperature elevation of the ejected material does not exceed 60degreesC. (C) 2002 Elsevier B.V. B.V. All rights reserved.