380 resultados para morphological asymmetry
Influence of morphological variables in photoelastic models with implants submitted to axial loading
Resumo:
Purpose: This study used 12 photoelastics models with different height and thickness to evaluate if the axial loading of 100N on implants changes the morphology of the photoelastic reflection. Methods: For the photoelastic analysis, the models were placed in a reflection polariscope for observation of the isochromatic fringes patterns. The formation of these fringes resulted from an axial load of 100N applied to the midpoint of the healing abutment attached to the implant with 10.0mm x 3.75mm (Conexão, Sistemas de Próteses, Brazil). The tension in each photoelastic model was monitored, photographed and observed using the software Phothoshop 7.0. For qualitative analysis, the area under the implant apex was measured including the green band of the second order fringe of each model using the software Image Tool. After comparison of the areas, the performance generated by each specimen was defined regarding the axial loading. Results: There were alterations in area with different height and thickness of the photoelastic models. It was observed that the group III (30mm in height) presented the smallest area. Conclusion: There was variation in the size of the areas analyzed for different height and thickness of the models and the morphology of the replica may directly influence the result in researches with photoelastic models.
Resumo:
Facial asymmetry is a common human characteristic and can occur on many levels, originate of genetic factors, and can be caused by traumas or due to cross bite and/or muscular disability. The aim of this study was to evaluate the relation between posterior crossbite, median line deviation and facial asymmetry. For this study 70 children aged between 3 and 10 years-old were examined and photographed. Using Microsoft Office Power Point 2007, horizontal lines and one vertical line on median line were drawn, to subjectively analyze facial discrepancies. In relation to overjet, the majority of children (78.6%) showed normal relation, followed by high overjet (17.1%), anterior crossbite (4.3%). In relation to overbite, the majority of children (60%) showed normal relation, 27.1% anterior opened bite (negative overbite), and 12.9% showed high overbite. Posterior crossbite was present in 27.1% of children. Among them, 68.4% showed unilateral crossbite on right side, 21.1% bilateral crossbite and 10.5% unilateral crossbite on left side. The relation between posterior crossbite and facial asymmetry, according to Fisher´s Exact Test (p=0.0970), there was no statistically significant association. In relation to median line, the association was statistically significant with posterior crossbite (p=0.0109) and with facial asymmetry (p=0.0310). There was association between posterior crossbite and median line deviation. There was no association between posterior crossbite and facial asymmetry.
Resumo:
Zinc oxide (ZnO) and aluminum-doped zinc oxide (ZnO:Al) thin films were deposited onto glass and silicon substrates by RF magnetron sputtering using a zinc-aluminum target. Both films were deposited at a growth rate of 12.5 nm/min to a thickness of around 750 nm. In the visible region, the films exhibit optical transmittances which are greater than 80%. The optical energy gap of ZnO films increased from 3.28 eV to 3.36 eV upon doping with Al. This increase is related to the increase in carrier density from 5.9 × 1018 cm-3 to 2.6 × 1019 cm-3. The RMS surface roughness of ZnO films grown on glass increased from 14 to 28 nm even with only 0.9% at Al content. XRD analysis revealed that the ZnO films are polycrystalline with preferential growth parallel to the (002) plane, which corresponds to the wurtzite structure of ZnO.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to analyse the characteristics of the asymmetries in the dominant and non-dominant limbs when kicking stationary and rolling balls. Ten experienced Brazilian amateur futsal players participated in this study. Each participant performed kicks under two conditions (stationary ball vs. rolling ball) with the dominant and non-dominant limbs (five kicks per condition per limb). We analysed the kicking accuracy, ball and foot velocities, angular joint displacement and velocity. The asymmetry between the dominant and non-dominant limbs was analysed by symmetry index and two-way repeated measures ANOVA. The results did not reveal any interaction between the condition and limb for ball velocity, foot velocity and accuracy. However, kicking with the dominant limb in both kicks showed higher ball velocity (stationary ball: dominant - 24.27 ± 2.21 m · s(-1) and non-dominant - 21.62 ± 2.26 m · s(-1); rolling ball: dominant - 23.88 ± 2.71 m · s(-1) and non-dominant - 21.42 ± 2.25 m · s(-1)), foot velocity (stationary ball: dominant - 17.61 ± 1.87 m · s(-1) and non-dominant - 15.58 ± 2.69 m · s(-1); rolling ball: dominant - 17.25 ± 2.26 m · s(-1) and non-dominant - 14.77 ± 2.35 m · s(-1)) and accuracy (stationary ball: dominant - 1.17 ± 0.84 m and non-dominant - 1.56 ± 1.30 m; rolling ball: dominant - 1.31 ± 0.91 m and non-dominant - 1.97 ± 1.44 m). In addition, the angular joint adjustments were dependent on the limb in both kicks (the kicks with non-dominant limb showed lower hip external rotation than the kicks with the dominant limb), indicating that the hip joint is important in kick performance. In conclusion, the kicks with the non-dominant limb showed different angular adjustments in comparison to kicks with the dominant limb. In addition, kicking a rolling ball with the non-dominant limb showed higher asymmetry for accuracy, indicating that complex kicks are more asymmetric.