371 resultados para tubo metálico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The zero-valent iron (ZVI) mediated degradation of the antibiotic ciprofloxacin (CIP) was studied under oxic condition. Operational parameters such as ZVI concentration and initial pH value were evaluated. Increase of the ZVI concentration from 1 to 5 g L−1 resulted in a sharp increase of the observed pseudo-first order rate constant of CIP degradation, reaching a plateau at around 10 g L−1. The contribution of adsorption to the overall removal of CIP and dissolved organic carbon (DOC) was evaluated after a procedure of acidification to pH 2.5 with sulfuric acid and sonication for 2 min. Adsorption increased as pH increased, while degradation decreased, showing that adsorption is not important for degradation. Contribution of adsorption was much more important for DOC removal than for CIP. Degradation of CIP resulted in partial defluorination since the fluoride measured corresponded to 34% of the theoretical value after 120 min of reaction. Analysis by liquid chromatography coupled to mass spectrometry showed the presence of products of hydroxylation on both piperazine and quinolonic rings generating fluorinated and defluorinated compounds as well as a product of the piperazine ring cleavage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aperfeiçoamento em equipamento para digestão de amostras por via úmida. É descrito um aperfeiçoamento em equipamento para digestão de amostras por via úmida que emprega tubos de digestão (20) fechados não encapsulados e aquecimento condutivo que possibilita a rápida decomposição de amostras botânicas, alimentícias, clínicas, ambientais e similares, promovendo um gradiente de temperatura em direção à parte superior do tubo de digestão, permitindo que a temperatura da fase gasosa seja inferior à da fase líquida, de forma que as digestões são realizadas à pressão pouco elevada e, consequentemente, os tubos de digestão utilizados podem ter paredes menos espessas, permitindo o rápido aquecimento e resfriamento das amostras, bem como baixo custo de operação e manutenção, simplicidade, alta frequência analítica,; redução do consumo de reagentes e diminuição da geração de resíduos, dito equipamento provido de um gabinete (10) que evita a contaminação da atmosfera do laboratório por vapores ácidos e a perda dos componentes voláteis da amostra durante o aquecimento

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to characterize and evaluate the performance of four models self-compensating drippers commonly used in drip irrigation systems in Brazil. To perform the study it was taking a sample of 25 emitters of each model. Evaluating their tubes (b) coefficient of manufacturing variation (c) wall thickness, (d) characteristic equation of the dripper, (e) internal diameter of the pipe, (f) spacing between emitters, (g) resistance water pressure at ambient temperature and to 40°C and (h) the tensile strength of the pipe with tension of 160 N and 180 N. The analysis showed variation coefficient of less than 0.045 for all manufacturing drippers (0.07 is maximum according to ABNT NBR ISO 9261). The exponents x of the equation pressure versus discharge ranged from 0.0082 to 0.0691 classifying them as self-compensating. From the results obtained it is clear that the tested products which are used in Brazil and used by irrigators had a satisfactory hydraulic performance in accordance with the standard.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research is to present a study on a relationship between the local head loss in connection of emitters in pipes with different diameters used in drip irrigation, with the online geometry of the emitter connectors, that allows an easy quantification of such head loss regarding of the size of the connectors. The experiment was carried out according to the Reynolds Numbers at a turbulent flow interval, obtained by the variation of the pipe outflow at a constant temperature of water. The results indicated that the friction factor of the Darcy-Weisbach equation can be estimated by the Blasius equation with the coefficients b = 0.300 and m = 0.25, for the above mentioned pipes. The head losses produced by the connections of the emitters, in relation to the pipe without emitter, was of 62%. A relationship between the kinetic load coefficient (K) and the index of blockage (IO) provoked by the online connector is presented by an algebraic equation which shows a coefficient of adjustment of approximately 96%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disposição construtiva aplicada em contenção ortodôntica. Patente de modelo de utilidade para uma disposição construtiva aplicada em contenção ortodôntica, compreendida por ser do tipo 3x3, com encaixe do tipo "macho-fêmea", sendo que na base da "fêmea" (1) são procedidas retenções (2) mecânicas para fixação por meio de colagem na face lingual dos caninos (3) inferiores, com resina composta, de modo que no interior da "fêmea" (1) é provido um orifício (4) para o encaixe do "macho" (5) e, no centro da cavidade é provido um anel (6) elástico que se encaixa precisamente numa canaleta feita no pino (7) de encaixe do "macho" (5), sendo que, na extremidade dos "machos" (5) podem existir prolongamentos (8) metálicos para retenção de acrílico (9) ou então meios de encaixe para soldagem de um fio metálico (10) espesso, que contorna a face lingual dos dentes (11); inferiores anteriores, de modo que, quando se optar pela retenção em acrilico (9), um fio metálico (10) mais delgado é soldado no terminal de encaixe do "macho" (5) e logo após, o fio (10) e o terminal são recobertos por acrilico (9), sendo que os "machos" (5) poderão ter angulações nos braços (12) de encaixes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)