501 resultados para Materiais cerâmicos : Microestrutura


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the following aspects regarding a soakaway, i.e. an infiltration well: i) entrance filter device; ii) permeability of the geotextile; and iii) emptying time. The 3.6 m³ infiltration well drains a roof area of 241.8 m². The entrance device is made up of layers of sand, gravel and geotextile set on a metal structure. The concrete rings that form the lateral walls were covered with geotextile, and bricks were laid between the soil and concrete rings. The infiltration well remained in operation during the entire testing period, and specific events were simulated to measure the emptying time. Permeability and fine particle tests were carried out after eight months of operation. Samples of geotextile taken from the bottom, the walls and the entrance device presented average permeability reductions of approximately 50.7%, 7.7% and 21.2%, respectively. The sand in the entrance device retained around 34.8% of fine particles and the gravel retained 0.13% in the same period. The infiltration rate was approximately 34.7 mm/h. The R2 coefficient for measured and calculated times was 0.97.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate surface rugosity among indirect esthetic materials (Vita VMK 95, Solidex, Artglass, Targis). Ten samples of each material in the cilindric shape with dimension 6 x 6 mm were manufactured. The surface were submitted to finishing and polishing, according to manufacturer's recommendations. The samples were submitted to measuremenst, using the Hommel Tester T500 device. The average values of maxim surface rugosity among the materiais ín question, were 5, 73pm; 5, 15pm; 6, 83 j.Jm e 3, 72 j.Jm, respectively. Sample were also subjectted to variance analysis- ANOVA (5%), had detected significance. Concluded that the material Solidex did not present significant statistical differences among groups, while Targis presented significant statistical differences in relation to the Artglass and the ceramic Vita vmk95.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Design - FAAC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia - IBILCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)