389 resultados para IMPLANT PLACEMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Amputations affect both the physical and the psychological aspects of an individual, causing significant impact on self-esteem. The main causes of finger amputations are work-related accidents with dangerous machinery, road traffic accidents, and animal bites, as well as systemic diseases such as diabetes. This report aims to describe a simple technique for fabrication of implant-retained finger prosthesis with a modified base of the retention system.Case Description and Methods: The O-Ring retention system was used with a modified hexagon-shaped base and a metallic capsule adapted to the acrylic resin to attach the prosthesis to the implant.Findings and Outcomes: The prosthesis was made with silicone, and after osseointegration, it was installed without complications, leading to a patient satisfied with the end result and encouraged to return to social life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare with pristine sites bone resorption and soft tissue adaptation at implants placed immediately into extraction sockets (IPIES) in conjunction with deproteinized bovine bone mineral (DBBM) particles and a collagen membrane.Material and methods: The mesial root of the third premolar in the left side of the mandible was endodontically treated (Test). Flaps were elevated, the tooth hemi-sectioned, and the distal root removed to allow the immediate installation of an implant into the extraction socket in a lingual position. DBBM particles were placed into the defect and on the outer contour of the buccal bony ridge, concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. The premolar on the right side of the mandible was left in situ (control). Ground sections from the center of the implant as well as from the center of the distal root of the third premolar of the opposite side of the mandible were obtained. The histological image from the implant site was superimposed to that of the contralateral pristine distal alveolus, and dimensional variation evaluated for the hard tissue and the alveolar ridge.Results: After 3 months of healing, both histological and photographic evaluation revealed a reduction of hard and soft tissue dimensions.Conclusion: The contour augmentation performed with DBBM particles and a collagen membrane at the buccal aspects of implants placed IPIES was not able to maintain the tissue volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the impact of replacing conventional mandibular complete dentures with implant-supported fixed complete dentures (ISFDs) on the oral health related quality of life (OHOOL) of edentulous patients and on the associated kinesiographic parameters. The patients had their complete dentures replaced by ISFDs and were assessed after 1, 2, 3, 6, and 12 months. An improvement of general OHQOL was observed 2 months after treatment with ISFDs. Kinesiographic recordings revealed significant mandibular vertical and horizontal opening increases and a greater vertical intrusion of the maxillary complete dentures during clenching after the treatment with ISFD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piezosurgery is a new and modern technique of bone surgery in implantology. Selective cutting is possible for different ultrasonic frequencies acting only in hard tissues (mineralized), saving vital anatomical structures. With the piezoelectric osteotomy technique, receptor site preparation for implants, autogenous bone graft acquistition (particles and blocks), osteotomy for alveolar bone crest expansion, maxillary sinus lifting, and dental implant removal can be performed accurately and safely, providing excellent clinical and biological results, especially for osteocyte viability. The aim of this review was, through literature review, to present clinical applications of piezosurgery in implant dentistry and outline their advantages and disadvantages over conventional surgical systems. Moreover, this study addressed the biological aspects related to piezosurgery that differentiate it from those of bone tissue approaches. Overall, piezosurgery enables critical operations in simple and fully executable procedures; and effectively, areas that are difficult to access have less risk of soft tissue and neurovascular tissue damage via piezosurgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture of porcelain structures have been related in either natural dentition or implant-supported restorations. Techniques using a composite resin or indirect methods can be used. This article presents a porcelain fracture on implant-supported metal-ceramic restoration. IPS Empress e.max laminate veneer restoration was used to repair the fracture. With this technique, it was possible to restore aesthetics and function, combined with low cost and patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biological principles of osseointegration caused the rehabilitation treatment with osseointegrated implant become a safe, well alternative accepted by the dental community for the high success rate, allowing the preparation of functional and aesthetic prostheses in edentulous and partial patients. We passed the initial phase of functional vision for an aesthetic approach, too, depending on the demands of the patient and the quest for excellence by professionals. Over these last years, implant treatment has undergone many changes in surgical and prosthetic protocols. The less invasive surgical techniques and the development of restorative materials, especially ceramics allow the prosthetic rehabilitation of high functional quality and aesthetics. The installation of implants in sockets immediately after extraction of teeth involved by fracture, periodontal disease, endodontic lesions, is part of the arsenal of techniques for rehabilitating a number of advantages that we get to the outcome of multidisciplinary treatment. For this, we must consider several criteria in its planning as a fundamental unit, adjacent teeth, multiple losses, system, form and number of implants, type of retention of the prosthesis components, the patient expectation of the outcome perspective, gingival biotype, standard of ridge resorption, the smile line, etc. occlusal analysis. With the three-dimensional placement of the implant can immediately join the biological processes of repair of the socket, implant osseointegration, speeding treatment time. Much has been made by companies in the surface treatment of endosseous implants to be osseointegration shortened and restorative procedures started earlier, bringing benefits to the patient and professional. Among the main advantages we can emphasize the preservation of the structures adjacent to the teeth replaced, minor resorption of bone tissue involved... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this in vitro study was quantify the micro strain development around the internal hexagon implants, varying the type of prosthetic coping. For This reason, three implants of internal hexagon were inserted into one polyurethane block in line placement. Microunit abutments were screwed onto the implants. Tangentially the implants were bonded the strain gauges, two to the center implant. Ten structures, each one containing three copings were cast in Co-Cr alloy, that were divided into groups in the first group, plastic copings were used, and in the second group machined copings were used. The superstructure’s occlusal screws were tightened onto Microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 ± 237,66 and the machined copings were 338,12 ± 223,01. The data were analyzed statistically by t- Student test. No statistically significant difference was found between the prosthetic copings (p= 0,867). It was concluded that to internal hexagon implants in line placement, the type of copings presented similar magnitude of micro strain after prosthetic occlusal screw was tightened

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study is to evaluate by histometric and immunohistochemistry analysis the effects of antimicrobial photodynamic therapy (aPDT) in alveolar prior to placement of mini-implants in animals with or without induced periodontal disease. Material and method: Thirty-two rats were used. Periodontal disease (PD) was induced by ligature in the lower left first molar. After 7 days of PD evolution, it was performed removal of the ligature and extraction of the left lower first molars in all animals. Thus, animals were divided into 2 groups (n=16) according to the treatments in the dental alveolus before immediate implant installation: MD (control) : mechanical debridement (MD), irrigation with 1 ml of saline solution followed by implant installation; aPDT- MD, irrigation with 1 ml of Toluidine Blue-O and low intensity laser (LLLT) and implant installation. Eight animals from each group were euthanized at 15 and 30 days after the installation of mini-implants. Specimens were processed for histologic, immunohistochemical and histometric analysis. The histometric data were processed for statistical analysis (Kruskall-Wallis and Dunn test; p <0.05). Result: In treatment analysis, results indicated that there was a greater BIC in implants installed in uncontaminated alveolus treated with a PDT ( p<0,05) and greater imuno-reactivity to OPG in bone issue treated with aPDT. Conclusion: The aPDT proved to be effective in bone loss control in no contaminated area and it has increased the bone loss and metabolic activity in alveolus irradiated prior to implant installation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES