523 resultados para Acrylic resin denture teeth
Resumo:
In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
The aim of this study was to evaluate and compare the roughness and superficial morphology of enamel and a composite restorative resin after different bleaching techniques application. Material and Methods: Bovine incisors were selected and standardized cavities were prepared on the buccal surface, which were restored with composite resin. The teeth were distributed according to the following treatments: G1- bleaching with 10% carbamide peroxide (CP); G2 - bleaching with 38% hydrogen peroxide (HP); and G3 - bleaching with 38% of HP associated to light irradiation. For G1, the bleaching gel was applied for 8 hours daily during 21 days. For G2 and G3, 3 sessions were performed, consisting of 3 applications of 15 minutes each, with 7 days of intervals between the sessions. For G3, the LED (470nm) light was used to activate the bleaching agent for 6 minutes. The surface of enamel and composite resin were evaluated before and after the bleaching procedures using a roughness tester and an atomic force microscope. Results: The results showed significant differences in surface roughness of enamel after bleaching only for G1 (Wilcoxon, p<0.05). For composite resin, neither group showed a statistical difference compared to control (Mann-Whitney, p>0.05). Conclusion: It was concluded that the increase in the roughness of enamel occurred only after bleaching therapy using a gel with 10% of CP. The bleaching procedures evaluated in this investigation did not increase the roughness or cause changes in the superficial morphology of the composite resin.
Resumo:
Objetive: Evaluate the deformations caused in the cutting edges in the K-file #25 (LK), subjected to pre-beinding of the apcial third using the following methods: finder-bending, cotton-pliers bendin and Flexobend, observed under scanning electron microscopy (SEM). Material and methods: Forty-eight LK#25 were divides into 4 groups (n=12); G1, control; G2, finger-bending; G3, cotton-plier bending, G4, Flexobend. The curvature was standardized in the apical segment of the file at 2 mm of D!. Was constructed a model of acrylic resin that correspond to a canal of 20º of curvature. The files were examined under SEM (260X). Data were analyzed using Fisher´s statistical test with a significance level of 5%. Results: The images showed no alterations in the LK, similar to G3, with no statistical difference. G3 and G4 were statistically different form the other groups (p<0.05). Conclusions: the finger-bending method to curve apical third of LK #25 did not alter the cutting edges, the cotton-pliers bending and Flexobend did alter the cutting edges of the files (AU)
Resumo:
Aim: The purpose of this study was to assess chlorhexidine effects on plaque index and salivary levels of mutans streptococci (MS) when used as the immersion solution for removable orthodontic appliances and added to their acrylic resin composition. Methods: Forty-five patients (6 to 12 years old) were randomly assigned into three groups with 15 patients each. Group I (control)—without orthodontic appliances disinfection; Group II—removable orthodontic appliances which had been immersed in 0.12% chlorhexidine digluconate overnight (8 hours), and Group III—orthodontic appliances in which 0.12% chlorhexidine digluconate solution had been incorporated into their resin composition. Saliva was collected for quantification of MS and evaluation of plaque index was performed before and after installation of orthodontic appliance at 0, 2, 4, 6, 8, and 10 weeks. Data were analyzed by using analysis of variance. Results: Number of MS colonies in saliva and plaque index showed no statistically differences among groups at the different periods (p > 0.05). Conclusions: It could be concluded that chlorhexidine incorporation into the acrylic resin of removable orthodontic appliances at 0.12% concentration and immersion of the appliance into 0.12% chlorhexidine solution were not effective in reducing plaque index and the number of MS in saliva.
Resumo:
Pós-graduação em Química - IQ
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study evaluated the effects of mechanical cycling on resin push-out bond strength to root dentin, using two strategies for fiber post cementation. Forty bovine roots were embedded in acrylic resin after root canal preparation using a custom drill of the fiber post system. The fiber posts were cemented into root canals using two different strategies (N = 20): a conventional adhesive approach using a three-step etch-and-rinse adhesive system combined with a conventional resin cement (ScotchBond Multi Purpose Plus + RelyX ARC ), or a simplified adhesive approach using a self-adhesive resin cement (RelyX U100). The core was built up with composite resin and half of the specimens from each cementation strategy were submitted to mechanical cycling (45 degree angle; 37 degrees C; 88 N; 4 Hz; 700,000 cycles). Each specimen was cross-sectioned and the disk specimens were pushed-out. The means from every group (n = 10) were statistically analyzed using a two-way ANOVA and a Tukey test (P = 0.05). The cementation strategy affected the push-out results (P < 0.001), while mechanical cycling did not (P = 0.3716). The simplified approach (a self-adhesive resin cement) had better bond performance despite the conditioning. The self-adhesive resin cement appears to be a good option for post cementation. Further trials are needed to confirm these results.
Resumo:
The effect in the gingival tissue of four distinctive types of relationships between the major conector and the gingival margin was investigated in eight subjects in association with the experimental gingivitis model. The subjects wore appliances constructed in acrylic resin (retained by means of embrasure hooks) throughout the day an night, except during meals. After the appliances had been placed, the subjects were abstained from any oral hygiene for twenty-one days. Records of the Plaque Index, Gingival Index and probing deplh were taken at baseline and at each week. Data showed that there was a small increase in the Plaque Index and Gingival Index for the four areas and that the degree of inflammation of the covered areas was higher in the area without relief
Resumo:
The lateral movement presents a combination of lateral condylar and protrusive displacement on the non-working side. The objective os this study was to check the differences in the adjustment of the semiadjustable articulator starting from two different initial positions, centric relation an intercuspal position using positional records of rotusion and lateral movements in acrylic resin for the adjustment of condylar guidance as for ennett Angle. Twenty pacients dentate and assintomatic were recruited and their adjustment were performed in the semiadjustable articulator checking the differences among the studied groups, not finding statistically significant differences. Concludes that, in semiadjustable articulator adjustment, starting the montage in centric relation or intercuspal position, the results obtained for the condylar guidande and Bennett Angle aren´t statistically diferents, as well there is no difference in condylar guidance adjustment using lateral or protrusive records.
Resumo:
Nowadays the search for aesthetic in removable dentures is considered a success clinical factor. Besides, both the selection of artificial denture teeth and the characterization of dentures have been based on the facial harmony and cultural factors. But these factors change over time. Therefore, the present study aimed to discuss the selection of artificial denture teeth in relation to patient’s variables such as face shape, skin color, hair color, eye color, age and gender. Moreover, artificial denture teeth’ color, shape and size were presented.