571 resultados para removable denture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. This study compared the residual monomer (RM) in four hard chair-side reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TRF and Ufi Gel hard-UGH) and one heat-polymerized denture base resin (Lucitone 550-L), which was processed using two polymerization cycles (short-LS and long-LL). It was also investigated the effect of two after polymerization treatments on this RM content.Methods. Specimens (n = 18) of each material were produced following the manufacturers' instructions and then divided into three groups. Group I specimens were left untreated (GI-control). Specimens of group II (GII) were given post-polymerization treatment by microwave irradiation. In group III (GIII), specimens were submitted to immersion in water at 55 degrees C (reline resins-10 min; denture base resin L-60min). The RM was analyzed using high performance liquid chromatography (HPLC) and expressed as a percentage of RM. Data were analyzed by two-way ANOVA followed by Tukey's test (alpha = 0.05).Results. Comparing control specimens, statistical differences were found among all materials (p < 0.05), and the results can be arranged as K (1.52%) > D (0.85%) > UGH (0.45%) > LL (0.24%) > TRF (0.14%) > LS (0.08%). Immersion in hot water (GIII) promoted a significant (p < 0.05) reduction in the RM for all materials evaluated compared to control (GI), with the exception of LL specimens. Materials K, UGH and TRF exhibited significantly (p < 0.05) lower values of RM after microwave irradiation (GII) than in the control specimens.Significance. The reduction in RM promoted by water-bath and microwave post-polymerization treatments could improve the mechanical properties and biocompatibility of the relining and denture base materials. (c) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to evaluate the correlation between central incisor form and face form in 4 racial groups and to investigate if there was agreement among experts in categorizing the central incisor forms. Method and Materials: A total of 160 subjects (40 whites, 40 mulattos, 40 blacks, and 40 Asians) ranging from 18 to 33 years of age were selected. Digital photographic records were made, 1 full-face and 1 intraoral view of the maxillary right central incisor. The outline tracings of the tooth and face images were obtained using Adobe Photoshop 5.0 software. The outline tracings were printed in distinct transparencies, and 3 prosthodontists determined if there was correspondence between the tooth and the face forms by superimposition of the transparencies. If there was disagreement among the prosthodontists' evaluations, the prevalent decision was considered. The experts also classified the central incisor forms into square, ovoid, tapering, or combination at 2 different sessions. At the first session, no instructions were given. At the second session, the prosthodontists were instructed to follow Williams' method of classification. Results: A correspondence between tooth and face forms was found in 23.75% of all cases. Agreement on the tooth form classifications among the prosthodontists occurred in 30.62% of all cases at the first session and 24.37% at the second session. Conclusion: There is not a highly defined correlation between central incisor form and face form in any racial group studied. In addition, the experts were not in fair agreement in categorizing tooth forms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this study were to evaluate the reliability and to validate a Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (OHIP-EDENT), an inventory for measuring oral health-related quality of life of edentulous subjects. The sample comprised 65 complete denture wearers (23 men, mean age of 69.1 +/- 10.3 years). The translated OHIP-EDENT was applied on two occasions with a washout period of 3 months. Reliability was assessed by an internal consistency analysis and a test-retest approach. A preliminary validation process was conducted by a qualitative approach/interview. Results of internal consistency showed a Cronbach's alpha of 0.86 or 0.90 for the first or second appointment respectively. Through the test-retest analysis, an intra-class correlation coefficient of 0.57 was found, and individual answers reflected a broad range of agreement. Interviewed volunteers (n = 6) comprehended most questions well. In conclusion, the Brazilian version of OHIP-EDENT is adequate for assessing the oral health-related quality of life for edentulous subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: the aim of this study was to compare the satisfaction and the quality of life in an elderly population using either mandibular conventional dentures or implant-retained overdentures.Materials and methods: A total of 34 patients were divided into two groups: group I-complete dentures users; group II - users of upper complete dentures opposed by implant-retained overdentures. The subjects were submitted to a questionnaire based on Oral Health impact Profile and oral health related quality of life to evaluate their satisfaction levels and quality of life with their prostheses. Data were evaluated using a non-parametric statistical analysis (Fischer test) with significant difference at alpha = 0.05.Results: There were no significant differences between the groups in relation to comfort, aesthetics, chewing ability, overall satisfaction, pain, functional, phonetic, social, and psychological limitations (p > 0.05). Comparing the stability of mandibular dentures, group II presented the better results (p < 0.05).Conclusion: Although the stability of the mandibular implant-retained overdenture was enhanced compared to a conventional denture, the quality of life and satisfaction levels were similar for both the groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inferior Alveolar Nerve (IAN) transposition is an option for prosthetic rehabilitation in cases of moderate or even severe bone reabsorption for patients that do not tolerate removable dentures. The aim of the present report is to describe an inferior alveolar nerve transposition with involvement of the mental foramen for implant placement. The surgical procedure was performed under local anesthesia, by the inferior alveolar, lingual and buccal nerve blocking technique. Centripetal osteotomy was performed, and bone tissue was removed, leaving the nerve tissue free in the foramen area. After that, transsection of the incisor nerve was performed, and lateral osteotomy was started from the buccal direction, toward the trajectory of the IAN. The procedure was concluded, by making use of a delicate resin spatula to manipulate the vascular-nervous bundle. The drilling sequence for placing the dental implants was performed, and autogenous bone was harvested using a bone collector attached to the surgical suction appliance. After the implants were placed, the bone tissue previously collected during the osteotomies and drilling processes was placed in order to protect the IAN from contact with the implants. The surgical protocol for inferior alveolar nerve transposition, followed by implant placement presented excellent results, with complete recovery of the sensitivity, seven months after the surgical procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207). and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors studied linear alterations processed on copper-aluminum casten MOD blocks, obtained from two expansion techniques (termic and hygroscopic by immersion). UNITERMS: Investment expansion. Thermic expansion. Hygroscopic expansion. Casten Technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Histopathology by hematoxilin-eosin (HE) and periodic acid Schiff (PAS), concomitant direct immunofluorescence (DI) against total human immunoglobulins and against Candida albicans, was effectuated in 25 persons dentures wearers. In 5 persons without chronic athrofic candidiasis (CAC) clinical signals in the palate the HE showed wise inflammatory elements in the connective tissue and the PAS marked the continuous basal layer, the intra-cellular grains of granular layer and the uniform parakeratin on epithelial surface. In 20 others, with palatal signals of CAC, in the HE was frequent the features encountered in Candida infected and PAS revealed, beside descontinuous lamina basal and epithelial surface covered by tide and discontinuous parakeratin, the presence of round bodies few largers that presents in the granular layer, casually isolated in the medial portion of ret pegs and connective papillae. In the first 5 persons the DI against total human immunoglobulins not showed signals of the humoral immunologic phenomena, the same was valid to others 20 patients with CAC clinical aspects. However the DI with conjugate against C. albicans in the 20 cases with CAC signals revealed suitable aspects of the structures assumed by Candida in tissues. Cultures of samples obtained of the persons with CAC signals was positive in 100% to Candida, 70% presumptively albicans, against 80% of positiviness to generus Candida, 67% presumptively albicans, in the persons without CAC signals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the castability of four copper-aluminium alloy according the melting casting method used. The specimens were made using polyester mesh screen, with 11 x 11 filaments of 0.26 mm thick, fixed along of two adjacent edges in wax bar, with the sprue attached at their junction. The alloys were in an electrical casting machine and a centrifugal casting machine with an air/gas torch. The castability values were obtained by the percentage of completed segments of the resulting cast alloy screen. It was verified that the use of the electrical casting machine produced higher castability values to the copper-aluminium alloys than those produced by a centrifugal casting machine with an air/gas torch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.