330 resultados para removable appliance
Resumo:
Nowadays the search for aesthetic in removable dentures is considered a success clinical factor. Besides, both the selection of artificial denture teeth and the characterization of dentures have been based on the facial harmony and cultural factors. But these factors change over time. Therefore, the present study aimed to discuss the selection of artificial denture teeth in relation to patient’s variables such as face shape, skin color, hair color, eye color, age and gender. Moreover, artificial denture teeth’ color, shape and size were presented.
Resumo:
AIM: The aim of this study is to present a clinical case in which an occlusal matrix device was used in a patient who needed to restore a posterior tooth. MATERIAL AND METHODS: A direct duplicate occlusal appliance was used (biteperf) in a patient who needed an occlusal restoration in two posterior teeth. RESULTS: Using the matrix helps having fast and accurate reproduction of the original anatomical details of the occlusal surface. The final result surprised with the presented restoration in terms of esthetic quality, despite the simplicity of the technique. CONCLUSION: Posterior teeth with initial lesions were confined to the occlusal surface of anatomically complex or fissured anatomy with or without signs of proximal caries wich are ideal candidates for this technique. The overlying enamel surface must be relatively intact; lesions of hidden or occult caries. CLINICAL SIGNIFICANCE: The aesthetic and time-saving benefits of the occlusal device (biteperf) are immediately clear. The matrix allows the fast and accurate reproduction of the anatomic details of the original occlusal surface of the tooth. The professionals who lack an artistic penchant and marked manual ability will be able to carry out excellent posterior resin composite restorations.
Resumo:
The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.
Resumo:
The rehabilitation with mandibular distal extension removable partial dentures (DERPD) is complex and the use of implants has been improving the functioning of this approach. The insertion bony level around of the last support tooth is an aggravating factor, since it can harm the longevity of the treatment. Thus, the aim of this research was to evaluate the displacement tendency of a mandibular DERPD associated to an implant, with different insertion bony levels and different connections between the RPD and the support tooth, by finite element analysis. Eight models were made: MA - DERPD, incisal rest, no bony loss; MB - DERPD, distal plate, no bony loss; MC - DERPD, incisal rest, no bony loss, with implant and ERA system; MD - DERPD, distal plate, no bony loss, with implant and ERA system; ME - DERPD, incisal rest, bony loss; MF - DERPD, distal plate, bony loss; MG - DERPD, incisal rest, bony loss, with implant and ERA system; MH - DERPD, distal plate, bony loss, with implant and ERA system. Loads of 50 N in each peak were applied. Displacement maps were obtained and showed that implant favors this association and the bony loss harms the prognostic of the prosthesis. It is concluded that: the introduction of the implant with ERA system reduced the displacement tendency of the tooth and supporting structures; introduction of distal plate reduced the movement tendency of the support tooth; the decrease of the periodontal support didn't influence significantly the displacement tendency of the models with distal plate distal, but it influenced the models with distal incisal rest.
Resumo:
Class III malocclusion is less common occlusal relationship, covering less than 5% of the population. There are various forms of treatment in Class III malocclusion. Depending on how the form is expressed Class III and age of the patient, the therapy may be orthopedic and orthodontic surgical orthodontics. The objective was to review the literature of the last 10 years about ways to compensatory treatment of Class III malocclusion. Several articles were published between 04/2003 and 04/2013 in the Pubmed database from the keyword "Class III malocclusion". However, only 19 articles that addressed the compensatory treatment of Class III were selected. Based on the selected items it was concluded that the treatment of Class III malocclusions in children before the peak of pubertal growth has better prognosis with greater effects orthopedic and orthodontic minor effects. The ideal treatment option for this condition is the Rapid maxillary expansion associated with maxillary protraction of the same. The treatment of Class III malocclusion in young people after the peak of pubertal growth is doubtful prognosis. You can opt to treat rapid maxillary expansion and maxillary protraction of the same or fixed appliance, however, orthopedic effects can be the same or smaller than the orthodontic effects, depending on the age of the patient. Depending on the degree of Class III malocclusion in adults, the treatment will consist of dental compensations or orthognathic surgery.
Resumo:
Early treatment of functional unilateral posterior crossbite during the mixed dentition is extremely important for contemporary Orthodontics, provides the correct positioning of osseous bases, teeth and temporomadibular joint when the stomatognathic system is in growth and development. These results generally develop into an adequate craniofacial relationship, reducing the necessity for more complex treatments at permanent dentition. The subject of this paper was to report patient 8 years old, diagnosed with functional unilateral posterior crossbite, and was treated by an expander appliance type Quad-helix emphasizing the long-term stability. The malocclusion was corrected in 3 months of active use of the appliance, 3 months for retention purposes and followed up during 7 years post-treatment. The stability in long term of functional unilateral posterior crossbite treated is closely related with early diagnostic, the elimination of the etiological factor associated with a correct appliance and the mechanic of treatment.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The main aim of this paper was to use the REZZ software to calculate the tank volume rainwater harvesting system. For this purpose, rain data of Ponta Grossa-PR-Brazil were used considering different statistical treatment (average, 75%, 85%, 95% and 99% of confidence) and different roof areas (50, 80, 120 and 200 m2). The harvesting system was considered only for toilet flush in households with 3, 4 and 5 inhabitants. There were applied the following methods/concepts: Flow equalization (Rippl); Brazilian method as well the English and German practical methods. Further, the mass-balance was simulated for some conditions. All considered methods are described in NBR15527/07, the Brazilian standard for rainwater harvesting. As expected, the results pointed out for huge differences depending on the choice method and the statistical treatment of the rain data. The REZZ appliance showed to be useful thus permitting to set different conditions and to obtain rapid results in order to assist designers to adopt the best cistern volume for each particular case.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
A large number of metal alloys are used in Dentistry for the manufacture of fixed and removable dentures. In the oral cavity, these structures are exposed to a chemically aggressive medium, like saliva and mechanical efforts, like mastication. In addition, acidic solutions containing fluoride ions are also frequently used in dental treatments to prevent dental plates and decays development. In this context, it was considered important to investigate the influence that a fourth element could exert when added to the ternary alloy Ni-Cr-Mo, largely used in Brazil. Therefore, electrochemical tests were done to evaluate the resistance to corrosion of quaternary alloy 65Ni-25Cr-5Mo-5Ta and 65Ni-25Cr-5Mo-5W in NaF solution 0,08mol / L, pH = 4.7. For greater understanding the microstructure and morphology of alloys were studied, through metallographic analysis, using optics microscopy and electron microscopy scanning. For the electrochemical tests were applied techniques traditionally used in corrosion researches, such as: potential measures in open circuit (OCP) and cyclic polarization (CP). It was found that both quaternary alloys showed very similar results. Comparing these quaternary alloys with the ternary 65Ni-25Cr-10Mo, it was found that the quaternary alloys exhibit greater resistance to corrosion, in other words, less passivation current density than the ternary alloy, showing that it is advantageous to add a fourth element in the alloy
Resumo:
The product development field daily works in the chase of new materials and technologies that fulfills the requirements of the consumer market. So, projects are developed in order to theoretically predict what will actually happen. The production of household appliance is not different. To provide a pleasant bath to the costumer, the manufacture of a bathtub counts on many components. With this in mind, this work goal is to study the possibility of production by plastic injection of the assembly water source/overflow pipe used in bathtubs and compare its production cost with the cost of the assembly acquired from third parties. The injection process is widely used on the world stage because of its numerous advantages, however, due to the high cost of the molds, it is important to estimate the time required for the return of the initial investment. To do this, a model was designed to examine its dimensions and then initiate the study of the possibility to inject the components with the available injection machine and the production cycle. With the results, it was found that there was a reduction in the cost of the finished assembly, but a very long time to return the initial investment due to the current financial scenery of the country