369 resultados para olfactory discs


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of complementary heat treatment and water storage in reducing cytotoxicity of acrylic resins denture bases used in Brazil by the MTT assay. Material and Methods: First, nine specimens were fabricated from metal matrix in the form of discs with 14 mm in diameter and 1.2 mm of thick. Immediately after making, 24 or 48 hours after storage in distilled water, the samples of heat-polymerized resins were divided into 3 groups (n = 3) according to the type of thermal treatment: Group 1: samples were individually exposed to microwave energy (500 W for 3 minutes); Group 2: samples were immersed in water at 550 C for 60 minutes; Group 3: samples did not receive heat treatment. To prepare the extracts, 3 samples of each group were placed into vials containing 3 mL of culture medium and stored at 37°C for 24 hours. L929 cells were used and the MTT assay was performed to analyze the cellular metabolism. Two-factor analysis of variance was used to detect significant among groups at 5% significance. Results: After statistical analysis, the materials were classified according to the cytotoxic effect: non-cytotoxic, slightly cytotoxic; moderately cytotoxic; and strongly cytotoxic. The results showed that the resins ranged from moderately cytotoxic to non-cytotoxic, but no statistically significant difference among experimental groups. Furthermore, the water storage and thermal treatments reduced the cytotoxicity of the resins. Conclusions: It was concluded that the resins studied are potentially toxic and that treatments can decrease their cytotoxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the action of methyl salicylate in dissolving Resilon and gutta-percha. Material and method: Ten discs of Resilon, Alpha gutta-percha and ProTaper gutta-percha were prepared (10 mm diameter × 1 mm thick) and kept at 37 °C for 48 hours. Each sample was weighed in a balance of accuracy determining the initial mass. The specimens were immersed in methyl salicylate or xylene (control) for 5  minutes, rinsed in water for 30 minutes, dried and subsequently weighed in 24 hours intervals until the stabilization of weight (final mass). The solvent capacity was expressed by the difference between the final and initial mass. The data were analyzed by using ANOVA and Tukey test with significance level of 5%. Result: The results showed that the methyl salicylate was more effective on Resilon than on gutta-percha (p < 0.05). Methyl salicylate and xylene had similar solvent action on Resilon (p > 0.05). The xylene showed better performance on gutta-percha than methyl salicylate (p < 0.05). Conclusion: It was concluded that methyl salicylate did not show solvent action on gutta-percha, however it showed effectiveness in dissolution of Resilon. Thus methyl salicylate can be a possible alternative to the use of xylene during endodontic retreatment of teeth obturated with Resilon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze whether immersion in sodium fluoride (NaF) solutions and/or common acidic beverages (test solutions) would affect the surface roughness or topography of lithium disilicate ceramic. Methods: 220 ceramic discs were divided into four groups, each of which was subdivided into five subgroups (n = 11). Control group discs were immersed in one of four test beverages for 4 hours daily or in artificial saliva for 21 days. Discs in the experimental groups were continuously immersed in 0.05% NaF, 0.2% NaF, or 1.23% acidulated phosphate fluoride (APF) gel for 12, 73, and 48 hours, respectively, followed by immersion in one of the four test beverages or artificial saliva. Vickers microhardness, surface roughness, scanning electron microscopy (SEM) associated with energy dispersive spectroscopy, and atomic force microscopy (AFM) assessments were made. Data were analyzed by nested analysis of variance (ANOVA) and Tukey's test (alpha = 0.05). Results: Immersion in the test solutions diminished the microhardness and increased the surface roughness of the discs. The test beverages promoted a significant reduction in the Vickers microhardness in the 0.05% and 0.2% NaF groups. The highest surface roughness results were observed in the 0.2% NaF and 1.23% APF groups, with similar findings by SEM and AFM. Acidic beverages affected the surface topography of lithium disilicate ceramic. Fluoride treatments may render the ceramic surface more susceptible to the chelating effect of acidic solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aimed to evaluate the attractiveness, non-preference for feeding and antibiosis in straight and runner growth habit peanut cultivars to Stegasta bosquella (Chambers). Eight cultivars were evaluated, four of straight growth habit (IAC Tatu, IAC 22, IAC 8112 and IAC 5) and four of runner growth habit (IAC Runner 886, IAC 147, IAC 125 and IAC 503). Free-choice and no-choice feeding tests were performed, using pairs of overlapped leaf discs with 1.0 cm diameter, which were placed in Petri dishes where third instar larvae of S. bosquella were released. The attractiveness to the larvae was assessed in predetermined times, in addition to the dry mass consumed. In the antibiosis assay, the biological parameters were evaluated: period and viability of larvae, pre-pupae, pupae, and total, weight of larvae and pupae, sex ratio and longevity. None of the runner growth habit cultivars exhibited non-preference for feeding-type resistance. Among the straight growth habit cultivars, IAC 5 and IAC 22 were the least attractive and consumed in the free-choice feeding test, and IAC 5 and IAC 8112 were the least attractive in the no-choice test. The runner growth habit cultivars IAC 147 and IAC Runner 886 affected the larval survival of S. bosquella, exhibiting antibiosis-type resistance. For the straight growth habit cultivars, IAC 22 and IAC 8112 affected the larval viability, presenting antibiosis-type resistance. The straight and runner growth habit cultivars did not influence the biological parameters of weight of pupae, sex ratio and longevity of S. bosquella.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Pairs of enamel and dentin discs (3 mm in diameter) were obtained from 150 bovine teeth. In 75 of the pairs, one specimen had the enamel removed (Dentin Group). The dentin was removed from one specimen of the remaining 75 pairs (Enamel Group) and the other specimen was left unaltered (Enamel + Dentin). The evaluation of color, translucency and fluorescence was performed with a spectrophotometer using the CIE L* a* b*. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached, and two experimental subgroups, bleached with either 10% carbamide peroxide (CP10%) or 35% hydrogen peroxide (HP35%). The CP10% bleaching gel was applied 2 h/day for 14 days. The HP35% bleaching agent was applied using two applications of 30 min each, with a one week interval between each application. When not being bleached, the specimens were immersed in artificial saliva. The color, translucency and fluorescence ratings were assessed using spectrophotometry 7 days after the treatment. Regarding color, significant differences were found between bleaching techniques in the groups Enamel and Enamel + Dentin, with a higher color difference for HP35%. Bleaching did not change the translucency of the dental tissues. There were significant differences for fluorescence for the HP35% subgroups of Dentin and Enamel + Dentin, and for the CP10% subgroup of Enamel. Dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected.