441 resultados para Implante Bicon


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution with different implant systems through photoelasticity. Five models were fabricated with photoelastic resin PL-2. Each model was composed of a block of photoelastic resin (10 x 40 x 45 mm) with an implant and a healing abutment: model 1, internal hexagon implant (4.0 X 10 mm; Conect AR, Conexao, Sao Paulo, Brazil); model 2, Morse taper/internal octagon implant (4.1 x 10 mm; Standard, Straumann ITI, Andover, Mass); model 3, Morse taper implant (4.0 x 10 mm; AR Morse, Conexao); model 4, locking taper implant (4.0 x 11 mm; Bicon, Boston, Mass); model 5, external hexagon implant (4.0 x 10 mm; Master Screw, Conexao). Axial and oblique load (45) of 150 N were applied by a universal testing machine (EMIC-DL 3000), and a circular polariscope was used to visualize the stress. The results were photographed and analyzed qualitatively using Adobe Photoshop software. For the axial load, the greatest stress concentration was exhibited in the cervical and apical thirds. However, the highest number of isochromatic fringes was observed in the implant apex and in the cervical adjacent to the load direction in all models for the oblique load. Model 2 (Morse taper, internal octagon, Straumann ITI) presented the lowest stress concentration, while model 5 (external hexagon, Master Screw, Conexao) exhibited the greatest stress. It was concluded that Morse taper implants presented a more favorable stress distribution among the test groups. The external hexagon implant showed the highest stress concentration. Oblique load generated the highest stress in all models analyzed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of the bed in High Density Porous Polyethylene (Medpor) implants integration. Two different kind of beds -- corticalized and decorticalized -- were made in six dogs. The animals were killed thirty, sixty and ninety days after implantation. Blocks including implant and adjacent bone were harvested, submitted to histological procedures, stained in hematoxiline-eosine and analyzed in optic microscope. The results demonstrated an absence of infection and foreign body reaction associated with High Density Porous Polyethylene (Medpor) implants. Furthermore, bony and fibrovascular ingrowth could be observed into its pores. The best integration was noted in decorticalized group, in which occurred a greater bony and fibrovascular ingrowth in comparison to the corticalized group

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main impact of hearing loss, in childhood, is the difficult to speech perception. The hearing aids and the cochlear implant are resources used to decrease a result of hearing loss. After the adjustment of these resources, with the therapeutic process, is possible that children with profound hearing impairment develop their hearing abilities, so they will have possibilities to notice phonetic and phonological characteristics of the language. Different speech perception procedures investigate which phonetic and phonological characteristics of the speech segment can be noticed by children with hearing loss. This study aims at analyzing the audiology profile and the speech perception in deaf children and adolescent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mini-implant has become a device for anchorage quite widespread and current employee in Orthodontics. The effectiveness of mini-implant is mostly due for its stability primary, however is important to understand about factors that influence the stability. This article presents a review of literature in the database, and as a criterion for inclusion in articles published on the factors related to the stability of mini-implant carried out on humans and animals. The articles was selected according selection criteria related to stability, The factors of mini-implants stability have been described in the literature with scattered scientific information, most of them just as clinical observations. However, these factors of stability can be classified in relation to screw, professional and patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As an innovative transitory anchorage device, the mini-implants deserve to be described with details regarding its use and action during orthodontic treatment. Therefore, this paper intents to present some biomechanic criteria adopted to for a better use of mini-implants as anchorage in anterior retraction (space closure), molar distalization, mesial movement of the molars, intrusion of molars and as support to provisional implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This clinical report describes an adult patient referred for orthodontic treatment with mini-implants as anchorage to correct the root angulation of maxillary lateral incisors. The purpose of this report was to demonstrate the versatility of mini-implants placed in a vertical direction in esthetic areas. During orthodontic treatment, some aspects must be observed to preserve the interim restoration against the occlusal loads to avoid screw fracture. A fixed appliance was placed to correct the position of the maxillary anterior teeth and to complete the treatment. Acceptable esthetics and function were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)