312 resultados para Teeth


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) irradiation on the removal of root surface smear layer of extracted human teeth and to compare its efficacy with that of citric acid, ethylenediamine tetra-acetic acid (EDTA), or a gel containing a mixture of tetracycline hydrochloride (HCl) and citric acid, using scanning electron microscopy (SEM). Thirty human dentin specimens were randomly divided into six groups: G1 (control group), irrigated with 10 ml of physiologic saline solution; G2, conditioned with 24% citric acid gel; G3, conditioned with 24% EDTA gel; G4, conditioned with a 50% citric acid and tetracycline gel; G5, irradiated with Er:YAG laser (47 mJ/10 Hz/5.8 J/cm(2)/pulse); G6, irradiated with Er:YAG laser (83 mJ/10 Hz/10.3 J/cm(2)/pulse). Electron micrographs were obtained and analyzed according to a rating system. Statistical analysis was conducted with Kruskal-Wallis and Mann-Whitney tests (P < 0.05). G1 was statistically different from all the other groups; no statistically significant differences were observed between the Er:YAG laser groups and those undergoing the other treatment modalities. When the two Er:YAG laser groups were compared, the fluency of G6 was statistically more effective in smear layer removal than the one used in G5 (Mann-Whitney test, P < 0.01). Root surfaces irradiated by Er:YAG laser had more irregular contours than those treated by chemical agents. It can be concluded that all treatment modalities were effective in smear layer removal. The results of our study suggest that the Er:YAG laser can be safely used to condition diseased root surfaces effectively. Furthermore, the effect of Er:YAG laser irradiation on root surfaces should be evaluated in vivo so that its potential to enhance the healing of periodontal tissues can be assessed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental trauma has been considered as a public health problem that affects mainly children and youngsters and due to its impact on the patient's quality of life. This study presents the results of a 6-year survey of the occurrence and characteristics of dental trauma in patients admitted to the Service of Surgery and Oral and Maxillofacial Traumatology of the School of Dentistry of Aracatuba (UNESP, Brazil) after emergency care in hospital facilities in the region of Aracatuba, SP, Brazil. For such purpose, the clinical files of patients treated at the Service between 1999 and 2005 were reviewed. Information regarding gender, age, number of traumatized teeth, etiology and diagnosis of the trauma was collected from the files of patients with tooth injuries and recorded in case report forms specifically designed for this purpose. The results showed that from a total of 4112 patients admitted to the Service within the surveyed period, 266 (6.5%) had tooth injuries (172 males - 64.7%; 94 females - 35.3%). The total number of traumatized teeth was 496. Most patients belonged to the 16-20 year-old age group (20.3%) and the most frequent causes of tooth injuries were bicycle accidents (28.6%), motorcycle accidents (19.2%) and falls (18.8%). Injuries to the periodontal tissues were the most frequent type of tooth injuries (408 teeth; 82.26%), occurring in 118 primary and 290 permanent teeth. Among the injuries to the periodontal tissues, avulsion was the most common (32.86%) (29.41% for primary and 34.0% for permanent teeth), followed by extrusive luxation (19.15%) (25.21% for primary and 17.24% for permanent teeth). In conclusion, in the surveyed population, cases of tooth injuries were more frequent in males aged 16-20 years old due to cyclist accidents with predominance of injuries to the periodontal tissues, in particular, avulsions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi avaliada a resistência de união entre dentes e base de dentadura, ambos de resina acrílica. Os dentes foram incluídos em blocos cilíndricos de resina e, posteriormente, torneados, para se obterem cilindros de 5mm de diâmetro. Sobre a extremidade do dente, era adaptado um padrão de cera de mesmo diâmetro, que, após inclusão na mufla, era substituído por resina acrílica termicamente ativada pelo método de processamento convencional de base de dentadura. Como variáveis, usaram-se duas marcas de dentes, duas fases de inclusão (plástica e borrachóide) e aplicação ou não de detergente e monômero sobre os dentes. Os corpos-de-prova, antes dos ensaios de ruptura por tração, foram armazenados em água destilada, a 37ºC, por 2 semanas. Os resultados mostraram que: marca de dente e fase de condensação não influíram nos resultados; somente o uso de detergente ou de monômero aumenta a retentividade e o seu uso conjunto apresenta efeito acumulativo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interim restorations are frequently used in prosthodontic treatments. Many complex situations require the combination of fixed and removable partial prostheses. An appropriate interim restoration design that accurately implements the treatment plan is necessary to prepare the oral cavity for the prostheses, and to contribute to the preservation and health of remaining natural teeth, bone support, and gingival tissues. This report describes a modified technique for construction of interim restorations with a combination of fixed and removable partial prostheses. The technique consists of the construction of a milled fixed prosthesis and removable partial denture with metallic framework for use during extensive treatment, improving masticatory function and esthetics and preserving the periodontal health of supporting structures. This interim restoration can also serve as a template for the definitive restoration, allowing patient and dentist to evaluate appearance and function and helping to ensure the success of the definitive restoration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective:This study investigated the efficacy of different techniques for the union of fragments of a denture before repair and on the accuracy of the reposition.Materials and methods:For this study, 20 maxillary dentures made with Lucitone 550 heat-cured resin were used. Points were determined with a scanner on the cusp of the teeth, as a measurement of the segments. After digitisation, each model was exported to the AUTOCAD R 14 program and two-dimensional measurements of the distances between the marked points were made. After the initial analysis, the dentures were fractured into two segments using an impact test machine. For the repair, maxillary dentures were divided into two groups; in the first, the repair was carried out using Kerr's sticky wax and in the second group, Super Bonder was used to join the fragments, with subsequent inclusion of DENTSPLY((R)) Repair Material resin. After the repair, the points of the maxillary dentures were measured again. The numerical values obtained were tabulated to compare the measurements before fracture and after the repair. For statistical analysis, analysis of variance was employed, using a single factor and double factor, followed by the Tukey test with a reliability of 95%.Results:The results demonstrated a statistically significant difference between the materials used to join the dentures for repair, where the dentures were joined with sticky wax presented a larger variation in the distances between the points.Conclusion:The variation in distances between the points is influenced by the agent of repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.