329 resultados para Liga hanseática
Resumo:
Introduction: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). Material and Method: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. Results and Conclusions: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).
Resumo:
The development of electrocatalysts for the oxidation of methanol and ethanol is very important, because these alcohols may be used in the anode fuel cells which convert chemical energy directly into electrical energy with high efficiency, cleanly and with low noise. Thus, this study reports to the synthesis of nanocatalysts of PtAu supported on carbon by microemulsion method. The physical characterization of these catalysts is performed through the techniques of X-ray diffraction and transmission electron microscopy. The catalytic activity of the prepared materials was studied using conventional electrochemical techniques and also the technique of spectro-electrochemical in situ FTIR, which allows identification of intermediates and products of the reactions. From the x-ray diffraction, it was observed that the thermal treatment applied to catalysts favored incorporation of Au into the crystal lattice of Pt,that is, increased the formation of PtAu alloy. Micrographs indicated particle size about 3 nm to materials not heat treated and 9 nm to materials subjected to thermal treatment (heating at 150 ° C for 1h and 30 min in argon atmosphere). Current density oxidation of methanol on PtAu / C were superior to pure platinum. Spectroscopic results indicated the presence of formate in solution in 50:50 and the composition showed bands for CO2, indicating complete oxidation, in lower potential. During ethanol oxidation on the catalyst PtAu, the main product formed was acetate, product of incomplete oxidation. The good performance for methanol oxidation can be attributed to large amounts of oxygen species adsorbed on the catalyst surface, or an electronic effect.
Resumo:
The increased prevalence of diabetic individuals has become a public health problem. Diabetes Mellitus is a metabolic disorder characterized by an increase in plasma glucose levels. It impairs the physiological equilibrium in utilization of carbohydrate by tissues. The persistent hyperglycemia can produce deleterious effects on bone formation due the microvascular complication. The present paper reviews the bibliography linking the impact of glycemic control at complications associated at diabetes mellitus on osseointegration. In experimental models of diabetes it was observed a reduced level of bone-implant contact. This failure can be reduced by means of hyperglycemia control. Also, several studies point the beneficial effect of coated implant on osseointegration process. It is necessary to take special care into account for the placement of implants in diabetic patient and improve the percentages of implant survival. A rigorous control of plasma glycaemia, together with other measures, like as absence of chronic complications, good oral hygiene and regular medical follow-up has been related to rising the percentages of successful in diabetic patients.
Resumo:
Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.
Resumo:
During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O aço austenítico manganês, descoberto inicialmente por Robert Hadfield, em 1882, conhecido atualmente como aço Hadfield, continha em sua configuração inicial 12% de manganês e 1,2% de carbono. Apresentando grande resistência ao desgaste, provavelmente o maior na categoria de aciaria, ganhou rápida aceitação no mercado, sendo então propostas várias alterações em sua composição, como a introdução de vários elementos de liga, como o vanádio, molibdênio, titânio, enxofre, fósforo, cromo, níquel, entre outros. Este trabalho investigou a influência dos elementos de liga na resistência ao desgaste e no encruamento sofrido por esse material, em quatro composições que se diferenciam nos elementos de liga e em suas porcentagens. A resposta foi uma grande resistência ao desgaste da liga contendo titânio, entretanto esta não apresentou a maior profundidade de camada encruada.
Resumo:
Processos automatizados, como a furação, podem melhorar com o uso de métodos de controle e supervisão, com destaque para sensores e redes neurais artificiais. Neste estudo, foram utilizados diferentes sensores instalados em máquina-ferramenta para o registro dos sinais de força de avanço, potência elétrica, aceleração e sinal acústico, durante a furação de corpos de prova compostos por uma liga de titânio seguida de uma liga de alumínio. Os sinais e os diâmetros dos furos medidos na furação das amostras foram utilizados no treinamento da rede neural artificial. Os erros foram apresentados e analisados. Os resultados demonstraram alta capacidade da rede em estimar o diâmetro do furo nas diferentes condições de usinagem com erros baixos e até mesmo desprezíveis para a maior parte das aplicações industriais, mostrando assim eficiência do método proposto.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC