335 resultados para marginal mandibular resection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A metal coping may undergo changes during porcelain firing, which compromises its marginal adaptation. The use of NiCrTi alloy proposes to minimize this effect through the high melting point of titanium present in its composition. This study evaluated the influence of porcelain firing cycle on the marginal adaptation of NiCrTi copings in different preparation designs. Forty standardized metal dies were fabricated with the following combinations finish line/convergence of the axial walls: 1) shoulder/6°; 2) shoulder/20°; 3) sloping shoulder/6°; 4) sloping shoulder/20°. On each die a metal ceramic restoration coping was made. The die/coping set was stabilized with orthodontic elastics, divided into four equidistant areas with three measurement points each and a cementation pressure was simulated. The measurements were taken under a stereomicroscope (32×). After the first measurement, the copings were submitted to sintering cycles simulating porcelain application. For repeated measurements, the same procedures described above were performed. Data were submitted to Student’s-t test, 1-way ANOVA and Tukey´s test (α = 0.05). Adaptation means (µm) before and after porcelain firing in different preparations were: 1) 111.92 and 127.31; 2) 124.15 and 135.48; 3) 122.19 and 138.77; 4) 166.09 and 186.72; respectively. The porcelain firing impaired adaptation, regardless of the preparation design. The preparation in a 20° sloping shoulder provided a worse adaptation when compared with preparations that had 6° and 20° shoulder, which were statistically equal. The 6° sloping shoulder was statistically equal to the other three preparation designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective and Case report: The purpose of this paper is to describe the neutral zone technique in a patient with oral deformity on the right labial commissure due to the resection of an oral cancer, enhancing the difficulty resulting from mouth limited opening and the use of tissue conditioner material to determine the neutral zone. Complete denture was obtained through this technique, providing good retention and stability which made functional rehabilitation feasible to patient of his or her masticatory function. Final considerations: The neutral zone technique in complete dentures will determine a specific intraoral area for tooth position and denture base contour where the forces generated by lips, cheeks and tongue are neutralized. The objective of this technique is to provide an alternative approach for patients who presented an historic instability of lower complete denture: atrophic ridge, oral deformities and also with disorder problems. An oral rehabilitation using this technique improves comfort to the patient providing retention and stability of mandibular complete dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The authors tried to verify the anatomic location of the mandibular foramen and língula in dry jaws regarding the anterior and posterior border of the mandible and the incisure, alveolar border and mandibular base, in order to correlate the data with the sagittal split ramus osteotomy. Methods: There were evaluated 44 mandibles (88 sides) from the Morphology Department of the Araraquara Dental School of the São Paulo University (UNESP). The distances measured were previously deter - mined according to the figures presented in this article and were done by the use of a sliding caliper (Brow & Sharpe Digit-Cal Plus), with the mandibles positioned over a Erickson table, and the distan - ces were always measured in millimeters. Results: The pre-determined points and distances founded were X=17,67; Y=14,35; W=20,96 and Z=21,89 for the mandibular foramen, and the relationship between this anatomical structure and the língula shows that the mandibular foramen is in average 5,82 mm below the língula. Conclusions: The authors conclude that the mandibular foramen is lightly posterior in comparison with the ramus mandibular center and that the língula is a very important anatomic landmark for the ramus surgeries as well the knowledge of the distance between it and the mandibular foramen entrance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this paper was to verify if the final irrigation at 17% EDTA, separately or followed by chlorhexidine digluconate at 2% interferes on the apical marginal leakage in root canal overfilling, due to the use of two root canal filling materials (Sealer 26TM or SealapexTM). Methods: Forty lower incisors extracted, with a single root canal, were biomechanically prepared, at 2.0mm beyond the radicular apex, with ProTaper SystemTM, finishing it with the F3 instrument. Irrigation was accomplished with 1.0 mL NaOCl at 2.5% at each change of equipment caliper and, in the end, with 5.0 mL normal saline solution. After achieving this procedure, the foraminal channels was standardized with a file K 25 until its DO appears in the foraminal opening. From this moment, the teeth were subdivided into two groups of 20 specimens each, because of the final irrigation method used: I – irrigation with EDTA at 17% for 3min and II – identical protocol, thus, after EDTA aspiration at17%, it was again irrigated with chlorhexidine digluconate at 2%, also kept intra-canal for 3min. Each group was again sub-divided into two sub-groups (ten teeth each), according to the cement used (Sealer 26TM or SealapexTM), and filled by using a single gutta-percha F1 (ProTaperTM, Universal Filling), in such a manner that it goes 2.0 mm beyond the radicular apex. Soon after that, the teeth were immersed in Rhodamine BTM for 72h, vacuum and after the roots have been bucolingually grooved, the leakages marked were measured with program Image ToolTM. Results and Conclusions: The leakage magnitude was similar among themselves (p > 0.05), except for group Sealapex®, thus the final use with chlorhexidine reduced apical leakage (p < 0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess the use of chlorhexidine with several excipients as a dentin surface treatment and its effect on marginal adaptation of class V restorations with current-generation dentin bonding agents. A total of 120 human third molars were selected and allocated into 12 groups, with standardized buccal class V restorations randomly divided into preconditioned dentin rinsed with: water; water + chlorhexidine; ethanol; or ethanol + chlorhexidine. After rinsing of dentin (previously conditioned with 35% phosphoric acid) with the test solutions, the Adper single bond 2, prime and bond 2.1, and Excite bonding systems were applied randomly. Restorations were performed with FiltekTM Z350 XT composite resin. The resulting specimens were subjected to thermal and mechanical load cycling. Quantitative analysis of marginal adaptation was performed on epoxy replicas by means of scanning electron microscopy. Results were assessed by means of the Kruskal-Wallis test (percentages of continuous margins) and Wilcoxon test (differences between percentages of continuous margins before and after thermal cycling and mechanical loading), at a significance level of p < 0.05. Outcomes in the chlorhexidine-treated groups were not superior to those obtained with other treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)