297 resultados para ensaios clínicos aleatórios
Resumo:
A contaminant plume due to leachate infiltration was found in the solid waste landfill from Bauru, SP. The soil hydraulic conductivity (K) is an important parameter to understand the moving of this plume. This paper intends to show representative K values for the soils that occur in the vicinity of this landfill determined by field and laboratory tests. There are four soil types in the area: colluvium, alluvium, sandstone residual soil and the sandstone. Laboratory tests were performed using constant and variable head in rigid and flexible wall permeameters. Slug tests and hydraulic conductivity tests with the Guelph permeameter were also carried out in situ in the area. Representative K values of 3.7x10-7 m/s for the saturated zone and 2.4x10-8 m/s for the unsaturated zone were determined for the residual soil. A K value of 5.3x10-5 m/s was obtained for the colluvium soil. A great variation of K with depth was observed for the alluvium and the assumed average values for the saturated zone were 7.9x10-7 m/s and 1.1x10-4 m/s for the unsaturated surficial layer. An average K value of 3.3x10-8 m/s was determined in laboratory for the sandstone and it was assumed representative for this material.
Resumo:
Pós-graduação em Psicologia - FCLAS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Endometrial polyps are neoformations that result from focal hyperplasia of the endometrial basal layer associated with hormonal hyperstimulation. Their pathogenesis is still unclear, and there is no consensus on their natural history, actual relevance as pathologic entities, and relationship with endometrial neoplasia. Endometrial polyps are the most frequent indication of surgical hysteroscopy, but their optimal management remains controversial. Therefore, an overview of this condition may help choosing the most adequate treatment strategies.
Resumo:
Uma égua da raça Quarto-de-Milha, doadora de embriões, de vinte e três anos de idade foi atendida no Departamento de Reprodução Animal e Radiologia Veterinária da FMVZ – UNESP – Botucatu, apresentando uma massa ulcerada, de consistência firme, drenando secreção serosanguinolenta, medindo 15cm x 16cm x 14,8cm na mama direita. O exame citológico foi inconclusivo devido à baixa celularidade e predomínio de células inflamatórias. Foi realizada mastectomia unilateral e exame histopatológico e técnicas específicas que revelaram um carcinoma mamário túbulo-papilífero, com extensivo acometimento intralobular e intraductal, estroma abundante e infiltrado inflamatório polimorfonuclear acentuado e difuso. Este trabalho tem como objetivo relatar os achados clínico e histopatológicos de um caso de carcinoma mamário túbulo-papilífero em uma égua, e afirmar a importância do exame citológico e histopatológico no diagnóstico diferencial de processos inflamatórios e neoplasias.
Resumo:
The aim of this study was to build and validate a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) to apply a spray solutions containing water plus a food dye (Blue FDC) at 0,6% m v-1 mixed with two adjuvants: a polymer based anti drift formulation at 0,06% m v-1 and a sodium lauryl ether sulfate based surfactant at 0,2% v v-1. After a 10-second application the drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The wind tunnel had low levels of turbulence and high repeatability of the data, which means that the flow was uniform and able to be used for carrying out measures to estimate drift. The validation results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk potential under those spray technologies. The use of an adjuvant based on a polymer reduced the amount of drift from the nozzle compared to the surfactant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, the project of a new experimental facility to be installed at the Aerodynamics Division of the Institute of Aeronautics and Space is presented. This new facility will provide means to perform experimental campaigns to analyze the flow behavior at different rocket nozzle concepts using cold gas that will be obtained from a modification of the Pilot Transonic Wind Tunnel air system. The new installation will enable less expensive experiments in a more secure environment, since the cold gas experimental procedures do not demand fuel storage and burn and security procedures are much less severe. Furthermore, experiments can be carried with different types of sensors, commonly used in wind tunnel tests. Also, the optical access is facilitated enabling the use of optical techniques for the characterization of flow properties inside the nozzles, such as pressure and temperature sensitive painting. The full project design and the operation conditions will be showed, as also some technical considerations about the flor behavior in the facility
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)