327 resultados para Ultrasonography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocular surface diseases are often diagnosed in brachycephalic dogs. The ophthalmic parameters of the Shih Tzu dogs are evaluated in this study since this breed is among the most commonly affected by these diseases. In this study, ophthalmic parameters of this breed were partly studied under physical restraint. Schirmer tear test, breakup time test, aesthesiometry, biomicroscopy, non-contact specular microscopy, laser flaremetry, applanation tonometry, ultrasonography and ophthalmoscopy were carried in 48 eyes of 24 male and female dogs, aged from two to four years, weighing between 5 and 10kg. All dogs were from a breeding kennel. Descriptive statistics were applied to the data. Mean and standard error for Schirmer tear test was 26.145±0.803mm min-1; breakup time test, 13.668±0.538s; and aesthesiometry, 2.395±0.071cm. The biomicroscopy evaluation showed that 70.83% of the eyes had medial entropion; 42% caruncular trichiasis; 33% distichiasis, 27% mild paracentral corneal opacity; and 13% corneal melanosis. Mean and standard error for endothelial cell density was 2221.591±20.161cells mm-2; endothelial cell hexagonality, 63.770±1.805%; endothelial cell area, 451.895±4.179mm2; central corneal thickness, 0.490±0.007 mm; laser flaremetry, 1.720±0.216PC ms-1; applanation tonometry, 16.118±0.460mmHg; axial length, 20.255±0.134mm; lens thickness, 6.624±0.031mm; anterior chamber, 4.064±0.109mm; and vitreous chamber, 9.565±0.054mm. Ophthalmoscopy findings were not different from previous reports for other breeds. The results showed that the ophthalmic Shih Tzu parameters did not differ from other breeds according to data in the literature, except for the breakup time and Cochet-Bonnet aesthesiometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic low back pain is a difficult condition to be treated. As some patients respond positively to treatment and others do not present any improvements, one can think there are others conditional factors that need to be elucidated. By means of this study, we sought to investigate the association between the occurrence of the formation of a positive relationship between patient and therapist, assessed by the therapeutic alliance inventory, and the adequate recruitment of the deep abdominal muscles, as well as to verify the effect of a protocol intervention based on motor control exercises on levels of pain and disability. The recruitment of the transverse abdominal and internal oblique muscles was examined by ultrasound imaging in 12 subjects with nonspecific chronic low back pain before and after implementation of a protocol for motor control exercises, with subsequent application of the therapeutic alliance inventory questionnaire. No association was found between the level of therapist/patient alliance and muscle recruitment. The proposed protocol was effective in reducing the levels of pain and disability; however, recruitment of transverse abdominal and internal oblique muscles showed no significant changes in the end of the intervention. Based on these findings, we verified that the therapeutic alliance has no association with muscle recruitment in the short term. However, although there were no changes in muscle recruitment after the intervention program, the level of pain and disability was reduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SynopsisBackgroundCellulite refers to skin relief alterations in womens thighs and buttocks, causing dissatisfaction and search for treatment. Its physiopathology is complex and not completely understood. Many therapeutic options have been reported with no scientific evidence about benefits. The majority of the studies are not controlled nor randomized; most efficacy endpoints are subjective, like not well-standardized photographs and investigator opinion. Objective measures could improve severity assessment. Our purpose was to correlate non-invasive instrumental measures and standardized clinical evaluation.MethodsTwenty six women presenting cellulite on buttocks, aged from 25 to 41, were evaluated by: body mass index; standardized photography analysis (10-point severity and 5-point photonumeric scales) by five dermatologists; cutometry and high-frequency ultrasonography (dermal density and dermis/hypodermis interface length). Quality of life impact was assessed. Correlations between clinical and instrumental parameters were performed.ResultsGood agreement among dermatologists and main investigator perceptions was detected. Positive correlations: body mass index and clinical scores; ultrasonographic measures. Negative correlation: cutometry and clinical scores. Quality of life score was correlated to dermal collagen density.ConclusionCellulite caused impact in quality of life. Poor correlation between objective measures and clinical evaluation was detected. Cellulite severity assessment is a challenge, and objective parameters should be optimized for clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contents This study aimed to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery in healthy and undergoing subclinical and clinical mastitis goats. Thirty animals among Saanen and Alpine Brown goats were arranged in three groups, healthy goats (HG), goats with subclinical mastitis (SMG) and goats with clinical mastitis (CMG). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hyperechogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on HG and SMG and heterogeneity for animals on CMG. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry did not reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of end diastolic velocity and raise of pulsatility index between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of dairy goats with mastitis. It is a sensitive and specific method for the study of this disease. Doppler mode was unable to establish reliable criteria for diagnosis of subclinical mastitis. Moreover, the quantification of echogenicity is a useful technique for the evaluation of the milk in animals with mastitis; therefore, it is suggested that it can be used as complementary technique for the diagnosis of mastitis in goats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)