332 resultados para Super Austenitic Stainless Steel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biocampatibility of the commercial nylon band used as bone cerclage, comparing with traditional metal cerclage wires. Twenty one rabbits and fifteen rats, healthy and without orthopedics problems were used. A commercial nylon band and a surgical stainless steel wire 0 were used in right (SN) and left (SA) rabbits's hindlimb, respectively. Otherwise, on rats SN was on the left hindlimb, and SA on the right hindlimb. Both experimental species were divided into three groups according to the end of the evaluation period. Clinical, radiographic, macroscopic and histologically evaluation were performed at 30, 60 and 150 days postoperatively. All the animals showed normal limb function differences between groups were not observed at clinical and macroscopic evaluation. On both species, radiographic changes were slightly higher on SN. Histological differences were not observed in both species. Nylon bands do not cause foreign body reaction and other histological changes in rabbits and rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose:The aim of this study was to evaluate deformation, roughness, and mass loss of stainless steel, diamond-like carbon (DLC)-coated and zirconia drills after multiple osteotomies with sterilization procedures.Materials and Methods:Drilling procedures were performed using stainless steel (G1), DLC-coated (G2), and zirconia (G3) drills. All groups were divided in subgroups 1, 2, 3, 4, and 5, corresponded to drills used 0, 10, 20, 30, and 40 times, respectively.Results:No significant differences in mass and roughness were detected among all groups and subgroups. In SEM images, all groups revealed signs of wear while coating delamination was detected in G2. Drills from G1 displayed more irregular surface, whereas cutting edges were more regular in G3.Conclusion:Zirconia drills presented more regular surfaces whereas stainless steel drills revealed more severe signs of wear. Further studies must be performed to evaluate the putative influence of these findings in heat generation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental investigations were carried out using a Nd:YAG laser operating in pulsed mode for welding a lap joint between thin foil and thick sheet. The pulse energy was varied from 1.5 to 3.0 J at increments of 0.25 J with a 4 ms pulse duration. The base material used for this study was AISI 316L foils with 100 mu m thickness and sheet with 3.0 mm thickness. The welds were analysed by optical and electronic microscopy, tensile shear tests and micro hardness. The results indicate that pulse energy control is of considerable importance to join thin foil and thick sheet with good quality. The ultimate tensile strength of the welded joints increased at first and then decreased as the pulse energy increased. The process appeared to be very sensitive to the gap between couples. Large voids delimited by the molten zone boundary were observed in joints welded with high pulse energy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to value the possibility to join, for pulsed Nd:YAG laser welding, thin foils lap joints for sealing components in corrosive environment. Experimental investigations were carried out using a pulsed neodymium: yttrium aluminum garnet laser weld to examine the influence of the pulse energy in the characteristics of the weld fillet. The pulse energy was varied from 1.0 to 2.5 J at increments of 0.25 J with a 4 ms pulse duration. The base materials used for this study were AISI 316L stainless steel and Ni-based alloys foils with 100 mu m thickness. The welds were analyzed by electronic and optical microscopy, tensile shear tests and micro hardness. The results indicate that pulse energy control is of considerable importance to thin foil weld quality because it can generate good mechanical properties and reduce discontinuities in weld joints. The ultimate tensile strength of the welded joints increased at first and then decreased as the pulse energy increased. In all the specimens, fracture occurred in the top foil heat-affected zone next to the fusion line. The microhardness was almost uniform across the parent metal, HAZ and weld metal. A slight increase in the fusion zone and heat-affected zone compared to those measured in the base metal was observed. This is related to the microstructural refinement in the fusion zone, induced by rapid cooling of the laser welding. The process appeared to be very sensitive to the gap between couples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This experimental study aimed to evaluate the effects of central catalase inhibition on cardiovascular responses in rats exposed to sidestream cigarette smoke (SSCS) for 3 weeks. Methodology: A total of 20 males Wistar rats (320–370g) were implanted with a stainless steel guide cannula into the fourth cerebral ventricle (4thV). Femoral artery and vein were cannulated for mean arterial pressure (MAP) and heart rate (HR) measurement and drug infusion, respectively. Rats were exposed to SSCS for three weeks, 180 minutes per day, 5 days/week [carbon monoxide (CO): 100–300 ppm)]. Baroreflex was tested with one pressor dose of phenylephrine (PHE, 8 μg/kg, bolus) and one depressor dose of sodium nitroprusside (SNP, 50 μg/kg, bolus). Cardiovascular responses were evaluated before and 15 minutes after 3-amino-1, 2, 4-triazole (ATZ, catalase inhibitor, 0.001g/100μL) injection into the 4th V. Results: Vehicle treatment into the 4th V did not change cardiovascular responses. Central catalase inhibition increased tachycardic peak, attenuated bradycardic peak and reduced HR range at 15 minutes, increased MAP at 5, 15 and 30 min and increased HR at 5 and 15 min. In rats exposed to SSCS, central ATZ increased basal MAP after 5 min and increased HR at 5, 15 and 30 minutes, respectively, and attenuated bradycardic peak at 15 minutes. Conclusion: This study suggests that brain oxidative stress caused by SSCS influences autonomic regulation of the cardiovascular system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O tratamento endodôntico é uma etapa importante do protocolo de atendimento do reimplante dentário e tem uma relação direta com o aparecimento das reabsorções radiculares, maior causa de perda dos dentes reimplantados. O objetivo do trabalho foi analisar o processo de reparo no reimplante tardio de dente de macaco, utilizando o hidróxido de cálcio (Ca(OH)2) e o MTA como materiais obturadores de canal. Cinco macacos Cebus apella adultos tiveram seus incisivos laterais superiores e inferiores, direito e esquerdo, extraídos e deixados em meio ambiente por 60 minutos. Decorrido esse período, foi realizado o preparo biomecânico dos canais e os dentes foram divididos em dois grupos experimentais: grupo I - canal preenchido com pasta de Ca(OH)2 e grupo II - canal preenchido com MTA (Angelus®). Após o selamento da abertura coronária com ionômero de vidro, o ligamento periodontal foi removido e os dentes imersos em solução de fluoreto de sódio 2%, pH 5,5, por 10 minutos. Em seguida, os alvéolos foram irrigados com soro fisiológico e os dentes reimplantados e contidos por 30 dias com fio de aço e resina composta. A eutanásia dos animais foi realizada 60 dias após o reimplante. Os espécimes de ambos os grupos apresentaram reabsorção por substituição e pontos de anquilose ao longo dos três terços radiculares e ausência de reabsorção inflamatória. Não houve diferença significante entre os dois grupos com relação à reabsorção por substituição, porém a quantidade de anquilose foi significativamente maior no grupo do Ca(OH)2. Baseado nesses resultados conclui-se que o MTA pode ser uma opção clínica viável para a obturação de dentes tardiamente reimplantados que necessitam de um longo período de curativo com hidróxido de cálcio.