330 resultados para Immediate implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibilities of treatment with dental implants have revolutionized the field of oral rehabilitation in recent years, bringing a number of advantages over conventional prostheses. For years, a surgical protocol was followed that called for maintaining the implant without load for a certain period for osseointegration, but experimental studies have shown that immediate loading of implants also leads to the formation of peri-implant bone tissue along the time, similarly to that observed for conventionally loaded implants. This study aimed to conduct a literature review regarding the use of this alternative rehabilitation with single implants. The immediate loading of single-tooth replacements is presented as an excellent treatment alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adolescence has been proposed as an ontogenic period of vulnerability to stress. Nevertheless, the impact of stressful events during adolescence in cardiovascular activity is poorly understood. Therefore, the purpose of this study was to investigate the immediate and long-lasting effects of exposure to stressful events during adolescence in cardiovascular function of rats. To this end, we compared the impact of 10-days exposure to two chronic stress protocols: the repeated restraint stress (RRS, homotypic) and chronic variable stress (CVS, heterotypic). Independent groups of animals were tested 24 h (immediate) or three weeks (long-lasting) following completion of stress period. Exposure to CVS, but not RRS, during adolescence increased basal HR values without affecting arterial pressure, which was followed by augmented power of oscillatory component at low frequency (sympathetic-related) of the pulse interval (PI). RRS enhanced variance of the PI with an increase in the power of both low and high (parasympathetic-related) frequency components. RRS also increased the baroreflex gain. Neither RRS nor CVS affected systolic arterial pressure variability. The RRS-evoked changes in PI variability were long-lasting and persisted into adulthood while all alterations evoked by the CVS were reversed in adulthood. These findings indicate a stress type-specific influence in immediate and long-term effects of stress during adolescence in cardiovascular function. While immediate changes in cardiovascular function were mainly observed following CVS, long-lasting autonomic consequences in adulthood were observed only in animals exposed to RRS during adolescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the clinical survival rate of osseointegrated implants placed in the atrophic maxilla that has been reconstructed by means of autogenous bone grafts harvested from a cranial calvarial site. Further, we sought to analyse the level of pen-implant bone after prosthetic rehabilitation and to determine subjective patient satisfaction with the treatment performed. This study conformed to the STROBE guidelines regarding retrospective studies. Twenty-five patients who had received osseointegrated implants with late loading in the reconstructed atrophic maxilla were included in the study. The survival rate and level of pen-implant bone loss were evaluated. A questionnaire related to the surgical and prosthetic procedures was completed. The observed implant survival rate was 92.35%. The mean bone loss recorded was 1.76 mm in the maxilla and 1.54 mm in the mandible. The results of the questionnaire indicated a high level of patient satisfaction, little surgical discomfort, and that the patients would recommend the procedure and would undergo the treatment again. From the results obtained, it is concluded that the cranial calvarial site is an excellent donor area; calvarial grafts provided stability and maintenance of bone volume over the course of up to 11 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective clinical study of maxillary sinus lift procedures in the posterior region of the maxilla, using only blood clot as filling material, was conducted. Seventeen patients underwent a maxillary sinus lift procedure; 20 maxillary sinus regions were operated on and a total of 25 implants were placed. The sinus mucosa was lifted together with the anterior wall of the osteotomized maxilla and supported by the implants placed. Computed tomography (CT) scans were obtained immediately postoperative (T-initial) and at 3 (T-1) and 51(T-2) months postoperative for the measurement of linear bone height and bone density (by grey tones). Only one implant was lost in the first stage (96% success). After dental prosthesis placement and during up to 51 months of follow-up, no implant was lost (100% success, second stage). The difference in mean bone height between T-initial (5.94 mm) and T-1 (13.14 mm), and between T-initial and T-2 (11.57 mm), was statistically significant (both P < 0.001); comparison between T-1 and T-2 also presented a statistical difference (P < 0.001). Bone density had increased at the end of the period analyzed, but this was not statistically significant (P > 0.05). Thus, the maxillary sinus lift technique with immediate implant placement, filling with blood clot only, may be performed with a high success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this systematic review was to identify clinical studies on implants placed in the tuberosity region to determine the survival rate of these implants when compared to implants placed in other regions of the maxilla. A search for data published up until March 2014 was undertaken using the PubMed, Cochrane Library, Embase, and ScienceDirect databases. Eligible studies were selected according to inclusion and exclusion criteria. The first database search revealed 310 titles. After inclusion and exclusion criteria were applied, five studies remained for the detailed analysis. A total of 113 patients were followed for a period of 6-144 months; 289 implants were placed in the patients evaluated. There were eight failures/losses of dental implants in the tuberosity region; the overall survival rate was 94.63% for these implants. In controlled studies, the cumulative survival rates for implants placed in the maxillary tuberosity and other maxillary regions were 96.1% and 95%, respectively. In conclusion, implants placed into the maxillary tuberosity are a predictable alternative for the treatment of patients with insufficient bone volume in the maxillary region. However, randomized trials are needed to assess the effectiveness of this treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveThe aim of this clinical report was to reestablish the buccal bone wall after immediate implant placement. The socket defect was corrected with autogenous bone, and a connective tissue graft was removed from the maxillary tuberosity to increase the thickness, height, and width of the buccal bone and gingival tissue followed by immediate provisionalization of the crown during the same operation.Clinical ConsiderationsA 66-year-old patient presented with a hopeless maxillary left central incisor with loss of the buccal bone wall. Atraumatic, flapless extraction was performed, and an immediate implant was placed in the extraction socket followed by preparation of an immediate provisional restoration. Subsequently, immediate reconstruction of the buccal bone plate was performed, using the tuberosity as the donor site, to obtain block bone and connective tissue grafts, as well as particulate bone. Finally, immediate provisionalization of the crown followed by simple sutures was performed. Cone-beam computed tomography and periapical radiographs were taken before and after surgery. After 4 months, the final prosthetic crown was made. After a 2-year follow-up, a satisfactory aesthetic result was achieved with lower treatment time and morbidity.ConclusionThis case demonstrates the effective use of immediate reconstruction of the buccal bone wall for the treatment of a hopeless tooth in the maxillary aesthetic area. This procedure efficiently promoted harmonious gingival and bone architecture, recovered lost anatomical structures with sufficient width and thickness, and maintained the stability of the alveolar bone crest in a single procedure.Clinical SignificanceIf appropriate clinical conditions exist, immediate dentoalveolar restoration may be the most conservative means of reconstructing the buccal bone wall after immediate implant placement followed by immediate provisionalization with predictable healing and lower treatment time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In uncemented Ti6Al4V hip implants, the bone-stem interface is subjected to cyclic loading motion driven by the daily activities of the patients, which may lead to the complete failure of the implant in the long term. It may also compromise the proliferation and differentiation processes of osteoblastic cells (bone-forming cells). The main objective of this work is to approach for the first time the role of these organic materials on the bio-tribocorrosion mechanisms of cultured Ti6Al4V alloys. The colonized materials with MG63 osteoblastic-like cells were characterized through cell viability/proliferation and enzymatic activity. Tribocorrosion tests were performed under a reciprocating sliding configuration and low contact pressure. Electrochemical techniques were used to measure the corrosion kinetics of the system, under free potential conditions. All tests were performed at a controlled atmosphere. The morphology and topography of the wear scar were evaluated. The results showed that the presence of an osteoblastic cell layer on the implant surface significantly influences the tribocorrosion behavior of Ti6Al4V alloy. It was concluded that the cellular material was able to form an extra protective layer that inhibits further wear degradation of the alloy and decreases its corrosion tendency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa.Material and methodsThe mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3months, the animals were euthanized and ground sections obtained.ResultsSimilar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites.ConclusionsThe increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession.