632 resultados para Endodontic cements


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To evaluate in vitro the effectiveness of sodium hypochlorite (NaOCl). chlorhexidine (CHX) and live intracanal medicaments on microorganisms within root canals.Methodology Ninety-six human single-rooted extracted teeth were used. After removing the crowns, canal preparation was completed and the external root Surfaces were coated with epoxy resin. Following sterilization. The teeth were contaminated with Candida albicans and enterococcus faecalis. and were incubated at 37 +/- 1 degreesC for 7 days. The teeth were divided according to the irrigant solution or intracanal medicament: group 1. sterile physiologic solution (SPS) and calcium hydroxide (Ca(OH)(2)) paste: group 2. SPS and camphorated paramonochlorophenol (CPMC): group 3.SPS and tricresol formalin: group 4, SPS and CaOH2 + CPMC paste: group 5, SPS and PMC furacin; group 6.2.5%, NaOCl without intracanal medication: group 7, 2.0% CHX without intracanal medication and group 8, SPS Without intracanal medication (control group). Microbiological samples were collected with sterile paper points, and bacterial growth was determined. The data were submitted to the analysis of variance (ANOVA. P = 0.05).Results For C. albicans, groups 3 and S were statistically less effective than groups 1, 2. 4 and 5 (Kruskal-Wallis (K-W) = 65.241; gl = 7; P = 0.001). For E. faecalis, groups 6 and 8 were statistically less effective than groups 1-4 and 7 (K-W = 61.048; gl = 7; P = 0.001).Conclusions Ca(OH)(2) + CPMC paste was the most effective intracanal medicament for the elimination of the two microorganisms; 2.0% CHX solution was more effective than 2.5% NaOCl against E. faecalis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho avaliou o selamento marginal apical de canais radiculares obturados com os cimentos endodônticos Sealapex, Apexit, Sealer 26 e Ketac Endo. Utilizaram-se 136 raízes, cujos canais radiculares, após o preparo biomecânico, foram obturados pela técnica da condensação lateral ativa com os cimentos em estudo. Metade das amostras, imediatamente após as obturações, foram imersas na solução de azul de metileno a 2% e a outra metade após 6 meses de armazenamento em plasma sangüíneo humano. Observou-se que os cimentos Sealapex e Sealer 26 apresentaram infiltrações médias estatisticamente iguais entre si e menores que as observadas para os demais cimentos (p < 0,05). Amostras imersas no corante imediatamente após a obturação dos canais apresentaram infiltração média menor (0,829 mm) do que aquelas mantidas por 6 meses em plasma sangüíneo humano (1,275 mm). Estas diferenças foram estatisticamente significantes (p < 0,05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presença de umidade no interior do sistema de canais radiculares, após o preparo biomecânico e sua desinfecção, pode influenciar no selamento apical e no êxito da obturação endodôntica. O objetivo deste trabalho foi avaliar a influência do número de esterilizações em autoclave, sobre a capacidade e velocidade de absorção dos cones de papel empregados em Endodontia. Foram analisados 440 cones de papel número 40, dos quais dez cones de cada marca comercial receberam de zero à dez ciclos de esterilização em autoclave (134°C/15 psi/15 minutos). Após cada ciclo de esterilização, os cones foram avaliados quanto a capacidade e velocidade de absorção de solução de hipoclorito de sódio a 1%. Os dados foram submetidos à análise estatística por meio dos testes da ANOVA (dois critérios) e Tukey (5%). Pôde-se concluir que, quanto à capacidade de absorção, os cones que sofreram menor influência dos diversos ciclos de esterilização em autoclave foram, em ordem decrescente: Tanari, Tanari cell pack, Conne e Diadent cell pack. Quanto à velocidade de absorção, os cones que obtiveram os melhores resultados foram: Tanari cell pack, Tanari, Conne e Diadent cell pack. A autoclavação mostrou-se um procedimento viável, em até 10 ciclos, apenas para a esterilização de cones de papel absorvente da marca Tanari utilizados em Endodontia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass ionomer cements (GICs) are products of the acid-base setting reaction between an finely fluoro-alumino silicate glass powder and poly(acrylic acid) in aqueous solution. The sol gel method is an adequate route of preparation of the glasses used to obtain the GICs. The objective of this paper was to compare two powders: a commercial and an experimental and to investigate the structural changes during hardening of the cements by FTIR and Al MAS NMR. These analyses showed that the experimental glass powder reacted with organic acid to form the GICs and it is a promising material to manufacture dental cements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi analisar a morfologia dos cimentos Sealapex, Apexit, Sealer 26 (cimentos a base de hidróxido de cálcio) e Ketac Endo (cimento de ionômero de vidro), através da microscopia de força atômica, verificando-se as características de suas partículas após a obturação dos canais radiculares e após um período de seis meses de contato com o plasma sanguíneo humano. Utilizaram-se 16 dentes unirradiculares humanos extraídos e incluídos em blocos de resina após o preparo biomecânico. As raízes foram divididas em quatro grupos de quatro raízes cada e os canais radiculares obturados pela técnica de condensação lateral passiva com os cimentos em estudo. Verificou-se que o cimento Apexit foi o que mais sofreu desintegração após seis meses de imersão em plasma sanguíneo humano, seguido pelo Ketac Endo e Sealapex. Dentre todos os cimentos estudados, o Sealer 26 mostrou-se o mais uniforme e com a menor desintegração.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente trabalho, analisou-se a eficácia de uma nova técnica de esterilização de instrumental odontológico. Limas endodônticas contaminadas com Escherichia coli, Pseudomonas aeruginosa e Staphylococcus aureus foram esterilizadas em plasma de oxigênio formado através de uma descarga elétrica contínua de 75 mA. Os resultados demonstraram efetiva eliminação dos microrganismos testados, utilizando-se um processo a baixas temperaturas e em tempos menores que os preconizados para processos convencionais (forno de Pasteur e autoclave). Microrganismos gram-negativos foram destruídos em 1 minuto de exposição e gram-positivos em 10 minutos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo desse trabalho foi avaliar a influência da intensidade da luz e cor de uma resina composta no grau de dureza Knoop. Corpos-de-prova foram confeccionados utilizando-se matrizes de poliéster envoltas por um anel de cobre, contendo uma cavidade padronizada de 6 mm de diâmetro por 2 mm de espessura. Estas cavidades foram preenchidas com resina composta selecionada, Fill Magic - Vigodent, com as cores A3, B3, C3, D3 e I, fotopolimerizadas através de um fotopolimerizador Elipar, calibrado para produzir 3 intensidades de luz diferentes: 450 mW/cm², 800 mW/cm² e uma intensidade de luz crescente de 100 a 800 mW/cm². Foram confeccionados 90 corpos-de-prova em que o tempo de exposição da resina à luz halógena foi de 40 s. As amostras foram armazenadas em tubos de ensaio com água destilada a 37 ± 1ºC. Após este período, foram realizados os testes de dureza Knoop na região de superfície e fundo. Os resultados mostraram que houve diferença estatística em relação a intensidade de luz, entretanto em relação a cor, não houve diferença estatística. Os autores concluíram que a cor do compósito não influencia a dureza Knoop e que a intensidade progressiva promoveu os melhores resultados de dureza Knoop.