332 resultados para Confiabilidade


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Cell-dyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510) and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson's correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semi-automated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a proposal for the automation of the camera calibration process, locating and measuring image points in coded targets with sub-pixel precision. This automatic technique helps minimize localization errors, regardless of camera orientation and image scale. To develop this technique, several types of coded targets were analyzed and the ARUCO type was chosen due to its simplicity, ability to represent up to 1024 different targets and availability of source code implemented with the OpenCV library. ARUCO targets were generated and two calibration sheets were assembled to be used for the acquisition of images for camera calibration. The developed software can locate targets in the acquired images and it automatically extracts the coordinates of the four corners with sub-pixel accuracy. Experiments were conducted with real data showing that the targets are correctly identified unless excessive noise or fragmentation occurs mainly in the outer target square. The results with the calibration of a low cost camera showed that the process works and that the measurement accuracy of the corners achieves sub-pixel precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Saúde Coletiva - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 2001, it was estimated that pesticide used worldwide exceeded 2.27 billion kilograms, over 35%, of which, were herbicides. Brazil is considered one of the leaders in the production of sugarcane and mainly ethanol as fuel. The monoculture of sugarcane requires the usage of a range of pesticides, among these, the herbicides diuron and tebuthiuron. The degradation products most studied (DCA and DCPU) are diuron's, especially for toxicological characteristics of this herbicide that is identified as carcinogen and suspected to be endocrine disruptor in mammals. After optimization of the chromatographic separation using HPLC-UV, the analytical curve was constructed in solvent and subsequently in the matrix (surface water). The extraction method contains the usage of SPE (solid phase extraction) (Strata-X, 200 mg/6 mL), applicating 1L of sample and elution with 5 mL of acetonitrile / methanol (50:50, v/v). Analysis by HPLC/UV was performed in gradient mode, acetonitrile/water (70/30-74/26 by 1 min, 74/26 - 78/22 till 3.2 min, returning to initial conditions and remaining this way until 10 min), 018 column (Phenomenex, 4.6 mm diameter, 250 mm long and 5pm particle size) and detection at 254 nm. Tests F and t were performed to verify the presence of the matrix effect. There was matrix effect to all analytes, ranging from -33% (DCA) and 38% (tebuthiuron). Thereby the method was optimized and validated for analysis of diuron, tebuthiuron, and DCPU DCA in surface water using HPLC/UV. The data obtained show that in order to assure the analytical reliability desired the use of the analytical curves in the matrix for the quantification of these analytes in water is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS