130 resultados para welded joint


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aims to analyze the toughness of a welded joint in the presence of a crack through the analysis of maximum tension the material can withstand the presence of this type of defect, since a discontinuity is likely to occur in this type of joint and its detection and its design is simple, using non-destructive testing techniques. The study will be conducted through the CTOD test - Crack-Tip Opening Displacement, with type specimens SE (B) - Single Edge Bend taken from a weld in the L-C position in relation to the length (longitudinal axis) of a test tube. The main idea is to simulate the welding conditions for the manufacture of industrial pipes, made in boiler shops (pipe-shop) within petrochemical plants. These pipes are often subject to operation with flammable and toxic subjected to high pressures and temperatures, where one can break the line can cause irreparable damage to the plant, the environment and the health of surrounding communities. With this study we evaluate whether the weld metal has the same properties as fracture toughness of the base material. This study shows the importance of using a qualified welding procedure for performing quality welds while maintaining the properties of the fracture toughness of the base metal. It was found from the results of tests using a welding procedure described for carrying out welding ensures mechanical properties very close to the base metal, which in terms of design is great, since one can ensure that the weld will the same characteristics of the base metal specified for the assembly of the pipe

Relevância:

60.00% 60.00%

Publicador:

Resumo:

On the grounds of the great advances achieved over recent years, the process HF/ERW (High-Frequency/Electric Resistance Welding)welded pipe have played an active role in the oil and gas industry for deep water applications, at high and extremely low temperatures, under high pressure and in highly corrosive environments, gradually replacing manufactured pipes by other processes. However, studies have shown that defects in the welded joints are a the leading causes of pipelines failures, which has required the determination of toughness values in this region, in compliance with the strict recommendations of the codes and standards with manufacturers and construction companies, on the oil and gas sector. As part of the validation process required toughness values, this research project focuses on a microstructural analysis in HF / ERW tubes microalloyed, steel grade API 5CT N80, designed to explore oil and gas in deep waters, the subject of strategic relevance to the country because of the recent discoveries in the Santos mega fields: Tupi and Libra (pre-salt). In this scientific work will be presented and discussed the results of mechanical tensile and Charpy, a few CTOD tests curves (showing the trend of toughness values to be obtained), and the microstructures of the base material obtained by optical microscopy, with special emphasis on the formation of non-metallic inclusions in the welded joint

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work focuses on a study on the fatigue behavior of a microalloyed steel API 5L X70, used in pipes lines to transport oil and gas. These types of steels have excellent mechanical resistance values and ductility and therefore increased their study driven by increased demand for oil and especially natural gas, which consequently raises the need to build new pipelines to transport these products. The oil extraction units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 to 30 years in the marine environment, a hostile environment for high pressure, corrosion, low temperatures and the stresses caused by the movement of water and tides. For analysis, the S-N (stress versus number of cycles) curves were obtained from data collected from bodies-of-proof cylindrical longitudinal, transverse and that one removed from the weld area of the pipe, tested in accordance with ASTM E466. Tensile tests were performed for characterizing the mechanical properties of the samples and welded joints, concluded that the values meet the specifications of the standard API 5L. To characterize microstructural material, also metallographic analysis was made of regions of the base metal and the HAZ. The results of fatigue tests demonstrated a higher life for the specimens removed from the longitudinal direction the pipe, followed by those in the transverse direction and, finally, the welded joint. The origins of the fatigue cracks were determined by scanning electron microscopy (SEM)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram estudados o arranjo e o diâmetro médio das fibrilas colágenas do ligamento colateral medial da articulação do cotovelo do cão, isolado ou associado ao ligamento oblíquo e tracionado até a ruptura. Dezoito articulações foram divididas em três grupos. O primeiro grupo teve o ligamento colateral medial coletado, mas não tracionado; o segundo grupo teve o ligamento colateral medial tracionado isoladamente; o terceiro grupo teve os ligamentos colateral medial e oblíquo tracionados associadamente. O ligamento colateral medial não submetido ao ensaio de tração apresentou um padrão ondulado das fibras colágenas, o qual não foi totalmente destruído quando foi tracionado, associado ao ligamento oblíquo, e perdeu totalmente o padrão reticular das fibras colágenas quando testado isoladamente. Quando o ligamento colateral medial foi submetido à tensão isoladamente, o diâmetro médio das fibrilas colágenas aumentou em relação ao grupo não submetido à tensão. Associado ao ligamento oblíquo, o diâmetro médio das fibrilas colágenas foi o maior na região de inserção e o menor na região média, em relação aos outros grupos. Concluiu-se que o ligamento oblíquo pode favorecer a integridade da região de inserção do ligamento colateral medial, aumentando a eficácia de sua reconstrução após a lesão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was carried out with male and females broilers of two different commercial breeds to evaluate bone mineral density of the right femur head. A number of 600 one-day-old broilers were raised in an experimental poultry house up to 42 days of age at the School of Veterinary Medicine and Animal Science of UNESP, Botucatu, Brazil. After slaughter, three males and three females in each breed in each of the established gross scores were selected. Their femora heads were submitted to gross examination, and subsequently the thighs were submitted to the Veterinary Hospital for radiographic analysis. Femora were also submitted to bone resistance, Seedor index, and dry matter content analyses. All these bone quality characteristics were different between males and females, independent of breed. Breeds presented similar behavior. It was possible to establish correlations between bone quality parameters, and confidence intervals for bone mineral density values, correlating them to femoral degeneration score, which allows characterizing femoral head lesions by radiographic optical densitometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bolted joints are a form of mechanical coupling largely used in machinery due to their reliability and low cost. Failure of bolted joints can lead to catastrophic events, such as leaking, train derailments, aircraft crashes, etc. Most of these failures occur due to the reduction of the pre-load, induced by mechanical vibration or human errors in the assembly or maintenance process. This article investigates the application of shape memory alloy (SMA) washers as an actuator to increase the pre-load on loosened bolted joints. The application of SMA washer follows a structural health monitoring procedure to identify a damage (reduction in pre-load) occurrence. In this article, a thermo-mechanical model is presented to predict the final pre-load achieved using this kind of actuator, based on the heat input and SMA washer dimension. This model extends and improves on the previous model of Ghorashi and Inman [2004, "Shape Memory Alloy in Tension and Compression and its Application as Clamping Force Actuator in a Bolted Joint: Part 2 - Modeling," J. Intell. Mater. Syst. Struct., 15:589-600], by eliminating the pre-load term related to nut turning making the system more practical. This complete model is a powerful but complex tool to be used by designers. A novel modeling approach for self-healing bolted joints based on curve fitting of experimental data is presented. The article concludes with an experimental application that leads to a change in joint assembly to increase the system reliability, by removing the ceramic washer component. Further research topics are also suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barrel racing is one of the most popular uses of the American Quarter horse in North and South America. Although injury to the metacarpophalangeal joint frequently occurs in this sport, there is limited information describing the nature of these injuries. The aim of this study was to determine the most common radiographic abnormalities in barrel racing horses with lameness referable to the metacarpophalangeal joint. lameness examinations were performed on 63 barrel racing horses. Those found to be lame were subjected to radiographic examination. Lameness at trot was scored on a scale of 0-5 (0 = sound; 5 = inability to move). Data were analyzed using descriptive statistical analysis. of horses examined, 30 (47.6%) were lame with scores ranging from 1 to 4. Half of the lame horses (15 of 30) had grade 2 lameness of the right forelimb. Abnormal radiographic findings were more often present on the left forelimb and included signs of sesamoiditis (70%), villonodular synovitis (56.6%), osteoarthritis (36.6%), osteochondritis dissecans (13.3%), capsulitis (13.3%), and soft-tissue swelling (6.6%). Radiographic abnormalities indicated that sesamoiditis, villonodular synovitis, and osteoarthritis may be associated to mild-to-moderate lameness in barrel racing horses. Complementary sonographic evaluation is recommended to better characterize soft-tissue abnormalities. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies that have used retrograde axonal tracers (horseradish peroxidase alone or conjugated with wheat germ agglutinin) have shown that the temporomandibular joint (TMJ) is supplied with nerve fibers originating mainly from the trigeminal ganglion, in addition to other sensory and sympathetic ganglia. The existence of nerve fibers in the TMJ originating from the trigeminal mesencephalic nucleus is unclear, and the possible innervation by parasympathetic nerve fibers has not been determined. In the present work, the retrograde axonal tracer, fast blue, was used to elucidate these questions and re-evaluated the literature data. The tracer was deposited in the supradiscal articular space of the rat TMJ, and an extensive morphometric analysis was performed of the labeled perikaryal profiles located in sensory and autonomic ganglia. This methodology permitted us to observe labeled small perikaryal profiles in the trigeminal ganglion, clustered mainly in the posterior-lateral region of the dorsal, medial and ventral thirds of horizontal sections, with some located in the anterior-lateral region of the ventral third. Sensory perikarya were also labeled in the dorsal root ganglia from C2 to C5. No labeled perikaryal profiles were found in the trigeminal mesencephalic nucleus. on the other hand, autonomic labeled perikaryal profiles were distributed in the sympathetic superior cervical and stellate ganglia, and parasympathetic otic ganglion. Our results confirmed those of previous studies and also demonstrated that: (i) there is a distribution pattern of labeled perikaryal profiles in the trigeminal ganglion; (ii) some perikaryal profiles located in the otic ganglion were labeled; and (iii) the trigeminal mesencephalic nucleus did not show any retrogradely labeled perikaryal profiles.