127 resultados para vinyl sulfides
Resumo:
This paper presents the results of thermogravimetric analysis (TGA) tests in PVC (1.0; 2.0 mm) and HDPE (0.8; 2.5 mm) geomembranes exposed to weathering and leachate after 30 months. The aim of this paper is the comparison of fresh and exposed samples to assess the degradation process concerning the total loss of mass of geomembranes. The exposure was conducted in accordance with the recommendations of ASTM standards. The TGA tests were carried out according to ASTM D6370 and E2105. Results show, for instance, that for PVC geomembrane the largest reductions of plasticizers occurred for samples exposed to weathering. The loss of plasticizers after the exposure contributed to the decrease of deformation and consequent increase in stiffness. TGA tests shows to be a valuable tool to control the quality of the materials. © 2012 ejge.
Resumo:
In the present paper we investigated the effect of adsorbed PVA on Pt electrodes on classic electrochemical processes such as hydrogen UPD, oxygen reduction and CO electro-oxidation. Upon adsorption PVA blocks roughly 50% of the hydrogen sites and can not be removed from the Pt surface through cycling in the potential range of 0.05-1.0 V vs. RHE. Potentiodynamic experiments under controlled hydrodynamic conditions provided by rotating disk electrode experiments showed a negative impact of the adsorbed PVA on the oxygen reduction reaction (ORR). Cyclic-voltammetry results revealed that not even CO was able to remove PVA from the Pt surface. Regarding the oxidation of CO, the adsorbed polymer positively shifted the CO oxidation peak potential, therefore higher potentials are required to free the Pt surface from CO poisoning. In situ Fourier transform infrared spectroscopy evidenced that the presence of PVA shifted the linearly bound CO frequency toward higher wavenumbers, a process found to be independent of the Pt surface orientation. In situ electrochemical X-ray absorption spectroscopy results showed that PVA also impacted the electronic properties of platinum by decreasing the occupancy of the Pt conducting 5d band. Our findings clearly support the efforts toward understanding the nature of the interaction between polymers and metallic surfaces as well as the impact on technological applications (e.g. in PEMFCs). © 2013 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents results describing the physical, mechanical, and thermal properties (melt flow index - MFI and oxidative induction time - OIT) of high density polyethylene and poly (vinyl chloride) after weathering exposure (6, 12, 18, and 30 months). The materials exposed were geomembranes of two thicknesses: 1.0 and 2.0 mm (PVC) and 0.8 and 2.5 mm (HDPE). The climate parameters (average) obtained were 25 degrees C (temperature), 93 mm (precipitation), 66% (relative humidity), and 19 MJ/m(2). day (intensity of global radiation). Some results showed, for instance, that the behavior of the geomembranes changed after the exposures. A few minor variations in physical properties occurred. The density and thickness, for instance, varied 0.5-1.0% (average) for both the PVC and HDPE geomembranes. The mechanical properties changed as a function of the period of exposure. In general, some decreases were verified by the deformation of PVC. The samples became more rigid. In contrast, HDPE geomembranes became more ductile. Despite the variations in elasticity, some increases in deformability were verified. An MFI test showed some degradation in HDPE geomembranes. OIT tests revealed small values for both intact and exposed samples.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study aimed to evaluate the adhesion ability of eucalyptus lumber from three tillage systems, using adhesives: resorcinol formaldehyde and two adhesives in water emulsion based on vinyl poly-acetate. The management systems were characterized by three strata, the stratum one (E1) characterized by wood from coppice and 70 months of age, the stratum two (E2) characterized by wood and retirement age of 166 months and stratum three (E3), also characterized by retirement at 70 months of age. The wood was derived from a random mixture of the first two sawn logs, each three feet from the base, which comprised three treatments on the adhesive used. We evaluated the shear strength by compression tests and the percentage of wood failure in the glue line. Based on the results obtained, it can be said that the adhesion had satisfactory performance with all the resins used, and the average values of shear strength of the glue line were shown to be equivalent to the shear strength of solid wood only for the samples which adhered with 'Wonderbond' adhesive and also provide higher values for wood failure (97.64%). The highest density present in the wood of the second stratum (E2) influenced only sticking with the resorcinol formaldehyde resin. For polyvinyl acetate (Cascorez 2590), shear values decreased in the third management condition (E3).
Resumo:
Composites with antimicrobial activity are of great interest nowadays and the development of titanium dioxide with these functional properties presents interest in academic and industrial sectors.An approach to develop PE composite containing silver microparticles to have an antimicrobial effect is presented. To obtain such antimicrobial composites, LDPE/EVA were processed with Ag particles on TiO2 particles as inorganic carrier substance. Titanium dioxide nanoparticles (P-25) were covered with silver particles using Turkevich Method or citrate reduction method. The Ag/TiO2 particles were dispersed at concentration of 0,8 wt% and 1% wt% in LDPE/ethylene vinyl acetate copolymer (EVA)-(50% w/w) at the melt state in a Haake torque Rheometer. Silver microparticles were characterized with UV-Vis Spectroscopy. The composites thus prepared were characterized through XRD, Ares Rheometer, Scanning Electronic Microscopy (SEM) and JIS Z 2801 antimicrobial tests to study the effects of the addition of particles on rheological properties, morphological behavior and antimicrobial properties. The results showed that incorporation of silver/titanium dioxide particles on composites obtained systems with differents dispersions. The Ag/TiO2 particles showed uniform distribution of Ag on TiO2 particles as observed by SEM-EDX and antimicrobial tests according to JIS Z 2801 shows excellent antimicrobial properties.
Resumo:
Poly(p-phenylene vinylene) (PPV) derivatives are well known for their applications in polymer light emitting diodes (PLEDs). PPV derivatives are highly susceptible to photo-oxidation though, which is mainly caused by the scission of the vinyl double bond on the polymer backbone. In this work, we show that Langmuir-Blodgett (LB) films are less degraded than cast films of a PPV derivative (OC1OC6-PPV). Both films had similar thickness (similar to 50 nm) to allow for a more realistic comparison. Degradation was monitored with UV-vis and FTIR spectroscopies. The results indicated that cast films were completely degraded in ca. 400 min, while LB took longer time, i.e. about four times the values for the cast films. The differences can be attributed to the more compact morphology in the LB than in the cast films. With a compact morphology the diffusion of oxygen in the LB film is hampered and this causes a delay in the degradation process. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVO: Embora vários modelos de bancada inanimados tenham sido descritos para o treinamento de habilidades de sutura, até o momento, não existe um método ideal para esse ensino e aprendizagem durante a formação médica. O objetivo foi avaliar se a fidelidade dos modelos de bancada interfere na aquisição de habilidades de sutura em estudantes de medicina iniciantes na prática cirúrgica. MÉTODOS: 36 estudantes de medicina sem exposição prévia a habilidades cirúrgicas foram randomizados em três grupos (n = 12): treinamento de suturas baseado em materiais didáticos (controle); treinamento de suturas em modelo de baixa-fidelidade (modelo de bancada de etileno vinil acetato); ou treinamento de suturas em modelo de alta-fidelidade (modelo de bancada de pele de pata de porco). Foram aplicados pré e pós-testes (realização de pontos simples e pontos subdérmicos invertidos em língua de boi). Três ferramentas (Global Rating Scale com avaliação cega, tamanho do efeito e autopercepção da confiança baseada em uma escala de Likert) foram utilizadas para mensurar todas as performances de sutura. RESULTADOS: A análise após o treinamento demonstrou que os estudantes que treinaram nos modelos tiveram um melhor (p < 0.0000) desempenho na avaliação pela Global Rating Scale, quando comparados com o controle, independente da fidelidade do modelo. A magnitude do efeito (treinamento) foi considerada grande (> 0.80) em todas as mensurações. Após o treinamento os alunos sentiram-se mais confiantes (p < 0.0000) para executarem os dois tipos de suturas. CONCLUSÃO: A aquisição de habilidades de suturas no modelo de baixa fidelidade foi semelhante à prática no modelo de alta fidelidade, sendo que a melhora no desempenho dos participantes que treinaram nesses dois modelos foi superior à aprendizagem baseada em materiais didáticos.