113 resultados para uniform energy distribution
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effect of milk processing on the microstructure of probiotic low-fat yogurt was studied. Skim milk fortified with skim milk powder was subjected to three treatments prior to innoculation: thermal treatment at 85 degrees C for 30 min, high hydrostatic pressure at 676 MPa for 5 min, and combined treatments of high hydrostatic pressure (HHP) and heat. The processed milk was then fermented by using two different starter cultures containing Streptococcus thermophilus, Lactobacillus delbrueckii ssp. bulgaricus, Lactobacillus acidophilus, and Bifidobacterium longum. The microstructure of heat-treated milk yogurt had fewer interconnected chains of irregularly shaped casein micelles, forming a network that enclosed the void spaces. on the other hand, microstructure of HHP yogurt had more interconnected clusters of densely aggregated protein of reduced particle size, with an appearance more spherical in shape, exhibiting a smoother more regular surface and presenting more uniform size distribution. The combined HHP and heat milk treatments led to compact yogurt gels with increasingly larger casein micelle clusters interspaced by void spaces, and exhibited a high degree of cross-linking. The rounded micelles tended to fuse and form small irregular aggregates in association with clumps of dense amorphous material, which resulted in improved gel texture and viscosity. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The distribution of short-circuit current is investigated by means of two methods, one direct and the other analytic; both methods consider uniform probability distribution of line faults. In the direct method, the procedure consists of calculating fault currents at equidistant points along the line, starting from one of the end points and considering the other end open. The magnitude of the current is classified according to Brazilian standards (regulation NBR-7118). The analytic method assumes that the distribution of short-circuit currents through the busbar and the distribution of the line length connected to it are known, as well as the independence of values. The method is designed to determine the probability that fault currents through a line will surpass the pre-established magnitude, thus generating frequency distribution curves of short-circuit currents along the lines.
Resumo:
Broiler production in Brazil has turned into a very competitive activity in the late years. Constant innovation leads to higher productivity maintaining the same cost of production, which is a desirable situation. Lately one characteristic for broiler housing in Brazil has been the increase in birds density requiring the use of controlled environment through the use of fan and fogging systems in order to achieve better birds productive performance. Most Brazilian producer already uses cooling equipment however it is still unknown the right way to control the wind speed and direction towards the birds. This present research has the objective to evaluate the effect of the wind speed on the heat transfer from the birds to the environment for broilers at 27 days old. There was used 200 birds, placed in a wind tunnel measuring 1.10 m high by 1.10m wide x 10.0 m of length, and the birds density varied from 9, 16 and 20 birds/m 2. Two wind speed were simulated 340 rpm (1.0 m/s) and 250 rpm (0.3 m/s). The increase in the wind velocity related to the smaller bird densityled to a higher heat loss and to a more uniform temperature distribution in its exposed areas.
Resumo:
This work aimed to study evaporation distribution in a protected environment. The experiment was set up in polyethylene greenhouse at the Lageado Experimental Farm in the School of Agronomic Sciences (FCA, UNESP-Botucatu) in the winter of 2005. 132 500-ml plastic micro evaporimeters (13.7 diameter) were used used to obtain evaporation values and analyze spatial energy distribution. These micro evaporimeters were distributed in 44 equidistant points, at three different heights from the soil surface: 0.40, 0.80 and 1.20cm The tunnel-type greenhouse was 7.5 m wide, 27.5 m long and 3.20 m high at the center, and was covered with black shadow screen (sombrite) on the sides. Southeast/northwest orientation, based on true north, was used foro othe greenhouse longitudinal axis. For variable comparison, a geostatistics was used through the □GS+ program. From obtained data, it was concluded that: there was spatial variability at different points and heights of the microevaporation values obtained from micro evaporimeters were not greenhouse; the Class A Pan installed outside the greenhouse can be used to evaluate the internal evaporation.
Resumo:
This work aimed to study the energy distribution in protected environment during the winter of 2005. A plastic tunnel (27.5 m long, 7.5 m wide, 3.2 m high in the center and 2.00 m high in both lateral sides) was covered with polyethylene 100 micra and black shadow screen (sombrite) in lateral sides at the FCA/UNESP, Botucatu - SP. 142 minievaporimeters (500 ml volume and 147 cm2 area) were evenly distributed and set up at three heights: 0.40 m; 0.80 m and 1.20 m from soil surface in order to analyze energy distribution along the studied area. The greenhouse longitudinal axis was northwest/southeast, based on true north. Geosatistics principles and the GS+ Program were adopted to compare variables. From obtained results, it was concluded that there were significant evaporation variations at different points anf heights; the highest values were the ones closest to the soil surface (0.40m) in July and at highest heights (0.80 and 1.20m). Highest evaporations occurred in the southeastern side of the greenhouse.
Resumo:
Due to great difficulty of penetration of drugs through skin, different organized systems, such as liposomes, have been studied in order to increase percutaneous penetration. The aims of this work were to obtain and characterize small unilamellar liposomes containing caffeine (CAF). Liposomes composed by soy phosphatidylcholine - PS (40 mM) or hydrogenated PS - PSH (40 mM), with and without cholesterol - CHO (6 mM) and CAF (30 mg/mL), were characterized by size distribution, determination of mean diameter and encapsulation efficiency. Uniform size distribution with low polidispersity was observed. The mean of diameters obtained were: PS/CHO (64 nm), PS (80 nm), PSH/CHO (85 nm), PS/CAF (145 nm), PS/CHO/CAF (147 nm), PSH/CHO/CAF (152 nm), PSH (166 nm) and PSH/CAF (481 nm). The obtained encapsulation efficiency was 10.84% for PSH/CHO/CAF, followed by PS/CHO (6.61%), PSH/CAF (3.07%) and PS/CAF (1.57%).
Resumo:
The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA