28 resultados para thermocouple


Relevância:

10.00% 10.00%

Publicador:

Resumo:

As the psychrometric method is considered standard for the measurement of relative humidity, many studies have used aspirated thermocouple psychrometers connected to microloggers but, however, they do not detail how the aspiration of the air stream is done. However, one of the major difficulties of aspirated thermocouple psychrometers is to program and to connect it in micrologger, because specific programming and connection are requires, and still some skills in getting accurate measurements. This work aimed to provide the programming and the connection of the aspirated thermocouple psychrometer type T for the CR10X microloggers and CR23X of Campbell Scientific, evaluating the quality of measurements of temperature and air relative humidity in relation the a sensor Vaisala HMP50. The non-continuous measurements were made in the period 2006/09/04 to 2007/07/11 at Jaboticabal, SP. The air temperature measurements were similar between the Vaisala sensors and aspirated thermocouple psychrometer, but the relative humidity measurements were significantly different. The measurements obtained by the aspirated thermocouple psychrometer connected to CR10X micrologger were the most accurate. Using the programming and connection of a micro-fan to suck in the dry and moist bulbs of aspirated thermocouple psychrometer in microloggers models CR10X and CR23X, it is possible to obtain measurements of air temperature with good precision and accuracy, and measurements of air relative humidity with good precision, but accuracy is not always attainable due to the difficulties inherent to the physical processes that occur in the wet bulb, the skill in the use and maintenance of this equipment and the reservoir protection against radiative effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermocouple is used for obtaining the air temperature with sensitivity and optimum precision, beyond great advantage over the mercury or alcohol thermometer, because it generates electrical signals that can be stored in automated systems. However, when it comes to obtaining the relative humidity from thermocouple, it is needed caution due to other factors involved. In this study two sets of thermocouple psychrometers, aspirated and no-aspirated were evaluated, relative to a Vaisala set, from 17 to 31/01/2008 (15 days). From measurements of dry and wet bulb temperatures, the relative humidity value was obtained, and it was possible to compare them with the Vaisala set measurements. The two types of psychrometers showed precision and accuracy in measurements of air temperature, and only precision in measurements of relative humidity, being that the aspirated psychrometer presented more precision. Despite the no-aspirated psychrometer has lesser precision in measurements, it is more robust because it is independent of a 12 VDC micro-fan, making it, a sensor with lesser risk of inadequate measures. Both aspirated and no-aspirated psychrometers do not measure accurately the relative air humidity during night period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have compared the results of the external irrigation technique with those of a double irrigation technique with continuous intermittent movement. Maximum thermal measurements were made in the cortical part of 10 samples of bovine ribs during osteotomy to simulate the preparation of a surgical bed for the installation of dental implants at a depth of 10 mm Twenty specimens were drilled for each group: external irrigation and continuous movement (control group 1, CG1); external irrigation and intermittent movement (control group 2, CG2); double irrigation and continuous movement (test group 1, TG1); and double irrigation and intermittent movement (test group 2, TG2). The double irrigation technique gave significantly better results regardless of the drilling movement used. Thermal increases between samples was 19.2% in group CG1, 10.4% in CG2, 5.4% in TG1, and 3.4% in TG2. The double irrigation technique produced a significantly smaller increase in temperature in the cortical bone during both types of drilling (p = 0.001), which illustrated its greater efficiency compared with that of the external irrigation technique. (C) 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare temperature variation during osteotomies with trephine drills under different irrigation conditions: without irrigation, external irrigation, and double irrigation.Synthetic blocks of bone (type I density) were used for drilling procedures with an experimental computed machine, which measured the maximum temperature in the cortical bone during osteotomy with a bone cut that was 5 mm in both diameter and depth. Three groups were formed depending on the irrigation conditions: no irrigation (G1), external irrigation (G2), and double irrigation (G3). Fifty drillings were performed for each group.The average thermal increase in the groups was 21.7 +/- 1.52 A degrees C in G1, 14.2 A +/- 0.70 A degrees C in G2, and 12.4 A +/- 0.75 A degrees C in G3. The results presented statistically significant differences among all groups (alpha = 0.05).The double irrigation technique resulted in a smaller increase in temperature in the cortical bone model, demonstrating a greater efficiency, which may be beneficial when compared to external irrigation alone.The trephine has been widely used in removing small blocks for bone graft, especially the posterior mandible, where the possibility of heating may be higher due to the density of cortical bone in this area. So it is important that the professionals select instruments that can reduce the risks of complications in the proposed treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed to study the composting process using two methods of treatment, conventional and mechanized for the treatment of pruning/weeding waste and organic waste generated in the canteens of the FCT/UNESP. For this work, it was quantified the generation of the waste However, of the tests with pure organic compound, which had the best result was T1 - 70% RPC / 30% ROC, again indicating the feasibility of applying this condition in scales at the campus. The conventional treatment by composting was carried out on manual aerated piles: 70% residue pruning/weeding (RPC) and 30% organic waste from the canteen (ROC); 50% RPC / 50% ROC, 30% RPC / 70% ROC. The mechanized system consisted of a reactor of 190 liters – 50% RPC / 50% ROC, with air injection from a compressor for 15 minutes daily. The parameters characterized and monitored were pH, organic matter, organic carbon, ash, nitrogen kjedahl and phosphorus. The temperature measurements were taken daily by a digital thermocouple (top, middle and base of the piles and reactor)... (Completo abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to assess measurements of temperature and relative humidity obtained with HOBO a data logger, under various conditions of exposure to solar radiation, comparing them with those obtained through the use of a temperature/relative humidity probe and a copper-constantan thermocouple psychrometer, which are considered the standards for obtaining such measurements. Data were collected over a 6-day period (from 25 March to 1 April, 2010), during which the equipment was monitored continuously and simultaneously. We employed the following combinations of equipment and conditions: a HOBO data logger in full sunlight; a HOBO data logger shielded within a white plastic cup with windows for air circulation; a HOBO data logger shielded within a gill-type shelter (multi-plate prototype plastic); a copper-constantan thermocouple psychrometer exposed to natural ventilation and protected from sunlight; and a temperature/relative humidity probe under a commercial, multi-plate radiation shield. Comparisons between the measurements obtained with the various devices were made on the basis of statistical indicators: linear regression, with coefficient of determination; index of agreement; maximum absolute error; and mean absolute error. The prototype multi-plate shelter (gill-type) used in order to protect the HOBO data logger was found to provide the best protection against the effects of solar radiation on measurements of temperature and relative humidity. The precision and accuracy of a device that measures temperature and relative humidity depend on an efficient shelter that minimizes the interference caused by solar radiation, thereby avoiding erroneous analysis of the data obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel