31 resultados para thermal radiation
Resumo:
Eight non-lactating Alpine goats, averaging 57kg, were paired according to weight and assigned randomly to 2 groups of 4 animals, control (CG) and treatment (TG) with feed and water ad libitum. An adjustment period of 7 days with all animals at thermoneutral conditions was followed by a 28-day period when TG was exposed to air temperatures averaging 35.0 degrees C, from 0800 to 1700h, including simulated solar radiation, and thermoneutral conditions from 2700 to 0800h. CG remained under thermoneutral conditions. Respiratory frequency was greater, tidal volume lower, and respiratory minute volume greater for TG than CG (176 vs 30 breaths/min, P<.001, 105 vs 293ml, P<.01; 18.4 vs 9.21, P<.05). Respiratory evaporation and sweating rate as well as rectal and skin temperatures were greater for TG than CG (14.59 vs 6.32 kcal h(-1), P<.01; 43.97 vs.00 g m(-2) h(-1), P<.001; 40.0 vs 38.9 degrees C, P<.001; 39.3 vs 35.8 degrees C, P<.01). There was no difference between groups for hematocrit and feed intake, but water consumption was greater for stressed goats than control ones (28.3 vs 29.7%; 1.44 vs 1.49 kg/day; 3.07 vs 1.26 I/day, P<.05), Final body weights of both groups were similar to initial ones. It was concluded that non-lactating goats tolerated well a 35 degrees C day temperature which is 5 degrees C above the upper critical temperature, with a black-globe temperature of 39.1 degrees C and a Botsball temperature of 28.3 degrees C, though a certain degree of hyperthermia may occur, as long as thermoneutral conditions have prevailed during the night.
Resumo:
A kraft lignin derivative (KLD) obtained by reaction with p-aminobenzoic acid/phthalic anhydride was blended with poly(vinyl alcohol) (PVA) by solution casting from DMSO. PVA and PVA/KLD films were exposed to ultraviolet radiation (24, 48, and 96 h) and analyzed by thermogravimetry (TG), differential scanning calorimetry (DSC), infrared spectroscopy (FTIR), hydrogen nuclear magnetic resonance (H-1 NMR) spectroscopy, and scanning electron microscopy (SEM). PVA films show a loss of thermal stability due to irradiation. PVA/KLD reveals greater thermal stability than PVA and an increase in thermal stability after irradiation. These results suggest that the incorporation of KLD into PVA provides a gain in thermal and photochemical stability. FTIR, H-1 NMR, DSC, and TG results obtained for the blends suggest that intermolecular interactions between PVA and KLD chains are present. SEM micrographs revealed blend miscibility for a KLD blend content of up to 15 wt%, as observed at magnification of 1000 times. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.
Resumo:
Two wafers of the NIST (formerly NBS) glass standard SRM 612 recently irradiated have been compared to the pre-irradiated wafers RT3 and RT4 of glass SRM 962-7, stored for 9 years at 5°C, and SRM 962, stored for 20 years at room temperature. Track area densities on internal surfaces of the glass as well as track size measurements suggest that (1) the old SRM 962 and the more recent SRM 962a calibrations are consistent and (2) annealing of the fission tracks in the pre-irradiated wafers is negligible. This last experimental result enables a direct comparison of contemporary and previous fission track age calibrations. © 1995.
Resumo:
This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.
Resumo:
We investigate whether the equality found for the response of static scalar sources interacting (i) with Hawking radiation in Schwarzschild spacetime and (ii) with the Fulling-Davies-Unruh thermal bath in the Rindler wedge is maintained in the case of electric charges. We find a finite result in the Schwarzschild case, which is computed exactly, in contrast with the divergent result associated with the infrared catastrophe in the Rindler case, i.e., in the case of uniformly accelerated charges in Minkowski spacetime. Thus the equality found for scalar sources does not hold for electric charges.
Resumo:
We show that the response rate of (i) a static source interacting with Hawking radiation of a massless scalar field in Schwarzschild spacetime (with the Unruh vacuum) and that of (ii) a uniformly accelerated source with the same proper acceleration in Minkowski spacetime (with the Minkowski vacuum) are equal. We show that this equality will not hold if the Unruh vacuum is replaced by the Hartle-Hawking vacuum. It is verified that the source responds to the Hawking radiation near the horizon as if it were at rest in a thermal bath in Minkowski spacetime with the same temperature. It is also verified that the response rate in the Hartle-Hawking vacuum approaches that in Minkowski spacetime with the same temperature far away from the black hole. Finally, we compare our results with others in the literature.
Resumo:
Objective: The aim of this study is to analyze the effects of copper vapor laser radiation on the radicular wall of human teeth. Materials and Methods: Immediately after the crowns of 10 human uniradicular teeth were cut along the cement-enamel junction, a chemical-surgical preparation of the radicular canals was completed. Then the roots were longitudinally sectioned to allow for irradiation of the surfaces of the dentin walls of the root canals. The hemi-roots were separated into two groups: one (control) with five hemi-roots that were not irradiated, and another (experimental) with 15 hemi-roots divided into three subgroups that were submitted to the following exposure times: 0.02,0.05, and 0.1 s. A copper vapor laser (510.6 nm) with a total average power of 6.5 W in green emission, frequency of 16.000 Hz, and pulse duration of 30 ns was used. Results: The results obtained by scanning electron microscope analysis showed the appearance of a cavity in the region of laser beam impact, with melting, recrystallization, and cracking on the edges of the dentin of the cavity due to heat diffusion. Conclusions: We determined that the copper vapor laser produces significant morphologic changes in the radicular wall of human teeth when using the parameters in this study. However, further research should be done to establish parameters that are compatible with dental structure in order to eliminate thermal damages. © Mary Ann Liebert, Inc.
Resumo:
A methodology for analyzing the solar access and its influence on both air temperature and thermal comfort of the urban environment was here developed by applying the potentiality of GIS tools. Urban canyons in a specific area of a Brazilian medium sized city were studied. First, a computational algorithm was applied in order to allow the determination of sky view factors (SVF) and sun-paths in urban canyons. Then, air temperatures in 40 measurement points were collected within the study area. Solar radiation values of these canyons were determined and subsequently stored in a GIS database. The creation of thermal maps for the whole neighbourhood was possible due to a statistical treatment of the data, by promoting the interpolation of values. All data could then be spatially cross-examined. In addition, thermal comfort maps for summer and winter periods were generated. The methodology allowed the identification of thermal tendencies within the neighbourhood, what can be useful in the conception of guidelines for urban planning purposes.
Resumo:
Cooperative energy-transfer upconversion luminescence in Tb 3+/Yb 3+-codoped PbGeO 3-PbF 2-CdF 2 vitroceramic and its precursor glass under resonant and off-resonance infrared excitation, is investigated. Bright UV-visible emission signals around 384, 415, 438 nm, and 473-490, 545, 587, and 623 nm, identified as due to the 5D 3( 5G 6 → 7F J(J=6,5,4) and 5D 4 → 7F J(J=6,5,4,3) transitions, respectively, were readily observed. The results indicate that cooperative energy-transfer between ytterbium and terbium ions followed by excited-state absorption are the dominant upconversion excitation mechanisms herein involved. The comparison of the upconversion process in a vitroceramic sample and its glassy precursor revealed that the former present much higher upconversion efficiency. The dependence of the upconversion emission upon pump power, temperature, and doping content is also examined.
Resumo:
The thermal denaturation and aggregation of the HbGp, in the oxy- and cyanomet-forms, was investigated by DSC, AUC, DLS, optical absorption and CD, in the pH range from 5.0 to 7.0. Oxy-HbGp has a denaturation process partially reversible and dependent on the temperature. DSC melting curve is characterized by a single peak with Tc value of 333.4±0.2K for oxy-HbGp, while two peaks with Tc values of 332.2±0.1 and 338.4±0.2K are observed for cyanomet-HbGp, at pH 7.0. In acidic pH oxy- and cyanomet-HbGp are more stable showing higher Tc values and aggregation. AUC data show that, HbGp, at pH 7.0, upon denaturation, remains undissociated at 323K, presenting oligomeric dissociation at 333 (12±3% of tetramer and 88±5% of whole HbGp) and 343K (70±5% of monomer and 30±2% of trimer). DLS data show that the lag period before aggregation is dependent on the temperature and HbGp concentration. Optical absorption and CD results show that the increase of temperature leads to the oxy-HbGp oxidation and aggregation, above 331K, in acidic pH. CD data, for HbGp, present a greater thermal stability in acid medium than at neutral pH, with similar Tc values for both oxidation forms. Our data are consistent with previous studies and represents an advance in understanding the thermal stability of oligomeric HbGp structure. © 2012 Elsevier B.V.
Resumo:
The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins. © 2013 Informa UK Ltd.
Resumo:
This paper presents results describing the physical, mechanical, and thermal properties (melt flow index - MFI and oxidative induction time - OIT) of high density polyethylene and poly (vinyl chloride) after weathering exposure (6, 12, 18, and 30 months). The materials exposed were geomembranes of two thicknesses: 1.0 and 2.0 mm (PVC) and 0.8 and 2.5 mm (HDPE). The climate parameters (average) obtained were 25 degrees C (temperature), 93 mm (precipitation), 66% (relative humidity), and 19 MJ/m(2). day (intensity of global radiation). Some results showed, for instance, that the behavior of the geomembranes changed after the exposures. A few minor variations in physical properties occurred. The density and thickness, for instance, varied 0.5-1.0% (average) for both the PVC and HDPE geomembranes. The mechanical properties changed as a function of the period of exposure. In general, some decreases were verified by the deformation of PVC. The samples became more rigid. In contrast, HDPE geomembranes became more ductile. Despite the variations in elasticity, some increases in deformability were verified. An MFI test showed some degradation in HDPE geomembranes. OIT tests revealed small values for both intact and exposed samples.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The Polymeric Precursor Method has proved suitable for synthesizing reactive powders using low temperatures of calcination, especially when compared with conventional methods. However, during the thermal decomposition of the polymeric precursor the combustion event can be releases an additional heat that raises the temperature of the sample in several tens of degrees Celsius above the set temperature of the oven. This event may be detrimental to some material types, such as the titanium dioxide semiconductor. This ceramic material has a phase transition at around 600 ° C, which involves the irreversible structural rearrangement, characterized by the phase transition from anatase to rutile TiO2 phase. The control of the calcination step then becomes very important because the efficiency of the photocatalyst is dependent on the amount of anatase phase in the material. Furthermore, use of dopant in the material aims to improve various properties, such as increasing the absorption of radiation and in the time of the excited state, shifting of the absorption edge to the visible region, and increasing of the thermal stability of anatase. In this work, samples of titanium dioxide were synthesized by the Polymeric Precursor Method in order to investigate the effect of Fe (III) doping on the calcination stages. Thermal analysis has demonstrated that the Fe (III) insertion at 1 mol% anticipates the organic decomposition, reducing the combustion event in the final calcination. Furthermore, FTIR-PAS, XRD and SEM results showed that organic matter amount was reduced in the Fe (III)-doped TiO2 sample, which reduced the rutile phase amount and increased the reactivity and crystallinity of the powder samples.