96 resultados para swd: Smart Device
Resumo:
The development of an experimental switching stiffness device fcr shock isolation is presented. The system uses magnetic forces to exert a restoring force, which results in an effective stiffness that is used to isolate a payload. When the magnetic force is turned on and off, a switchable stiffness is obtained. Characterization of the physical properties of the device is presented. They are estimated in terms of the percentage stiffness change and effective damping ratio when switched between two constant stiffness states. Additionally, the setup is used to implement a control strategy to reduce the shock response and minimize residual vibration. The system was found to be very effective for shock isolation. The response is reduced by around 50 percent compared with passive isolation showing good correlation with theoretical predictions, and the effective damping ratio in the system following the shock was increased from about 4.5 percent to 13 percent. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work deals with the nonlinear piezoelectric coupling in vibration-based energy harvesting, done by A. Triplett and D.D. Quinn in J. of Intelligent Material Syst. and Structures (2009). In that paper the first order nonlinear fundamental equation has a three dimensional state variable. Introducing both observable and control variables in such a way the controlled system became a SISO system, we can obtain as a corollary that for a particular choice of the observable variable it is possible to present an explicit functional relation between this variable one, and the variable representing the charge harvested. After-by observing that the structure in the Input-Output decomposition essentially changes depending on the relative degree changes, presenting bifurcation branches in its zero dynamics-we are able in to identify this type of bifurcation indicating its close relation with the Hartman - Grobman theorem telling about decomposition into stable and the unstable manifolds for hyperbolic points.
Resumo:
The objective of this experiment was to evaluate effects of treatments with intravaginal progesterone (N) device and/or 48 h temporary weaning (TW) on reproductive performance of postpartum anestrous crossbred Angus x Nelore cows, throughout the breeding season (BS). Anestrous cows (n = 296; 53 5 DPP, body condition score between 2.5 and 3.5, on a 1-5 scale) were assigned randomly to four treatments (2 x 2 factorial design): (1) Control Group (no treatment; n = 73); (2) TW Group (48 h TW beginning on day 0 of BS; n = 70); (3) P4 Group (Intravaginal P4 device between days -7 and 0 of BS; n = 73); and (4) P4+TW Group (Intravaginal P4 device between days -7 and 0 of BS followed by 48h TW; n=70). on day 0 of BS (when P4 devices were removed and TW was initiated), cows had their ovaries evaluated by ultrasonography aiming to evaluate size of the largest follicle. Signs of behavioral estrus were observed twice a day (morning and evening), between days 0 and 25 of BS, and cows observed in estrus were inseminated 12 h later. Between days 26 and 80 of BS, cows were submitted to natural service. Pregnancy diagnosis was conducted by transrectal ultrasonography on days 32 and 53 (pregnancies by AI) and 114 (pregnancies by natural service). Rates of detection of estrus during the first 3 days and within 25 days of BS were greater in cows receiving TW (45.0% compared with 9.6% and 50.0% compared with 29.5%, respectively; P < 0.01). Conception rate in cows inseminated in the first 3 days of BS was greater in cows treated with P4 (54.8% compared with 11.1 %; P < 0.01). Combining P4+TW increased pregnancy rate in the first 3 days (Control: 1.4%, TW: 4.3%, P4: 8.2% and P4+TW: 24.3%; P < 0.01) and in 25 days of BS (Control: 10.9%, TW: 7.1%, P4: 13.7% and P4+TW: 28.6%; P < 0.05). Pregnancy rate at the end of BS did not differ among treatment groups. In conclusion, TW alone increased estrous behavior whereas P4 alone benefited conception. Combining P4 with TW improved pregnancy rate with direct benefits to behavioral estrus and conception. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.
Resumo:
Studies on patterns of habitat use by mammals are necessary for understanding the mechanisms involved in their distribution and abundance. In this study, we used the spool-and-line method to investigate habitat utilization by two sigmodontine rodents from Brazilian Cerrado, Necromys lasiurus and Oryzomys scotti. We conducted the study in a Cerrado area in central Brazil (15 degrees 56'S and e 47 degrees 56'W) where the animals were caught in an area of 7.68 ha of Cerrado sensu stricto. Captured individuals were marked, equipped with a spool-and-Line device, and released at the same capture point. The next day we followed the thread to record their daily movements and find their nests. To investigate microhabitat selection we compared habitat characteristics along traits of each studied species with general habitat characteristics of the study area. Although the mean 24-h distance was greater for N. lasiurus (mean +/- SE: 41.9 +/- 42.2 m, N=3) than for O. scotti (28.7 +/- 14.2 m, N=6) this difference was not significant (Mann-Whitney test, U=26, P>0.6). We detected significant differences among observed microhabitats variables of both species and available microhabitat characteristics as determined by discriminant analysis (Wilks's lambda F=3.001; df=14, 116; P<0.001). Both species were associated to microhabitat characteristics whose values differed markedly from the overall available habitat. Along the first canonical discriminant function of the DFA both them were associated with greater grass height than the mean height available and along the second axis N. lasiurus selected areas with higher fruit availability and more shelters than those selected by 0. scotti. For stronger inferences regarding differential patterns of habitat utilization by Cerrado rodents we suggest the simultaneous use of both spool-and-line and standard trapping methods. (c) 2005 Deutsche Geseltschaft fur Saugetierkunde. Published by Elsevier GmbH. ALL rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the before and after test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.
Resumo:
In this paper were investigated phase-shift control strategies applied to a four cells interleaved high input-power-factor pre-regulator boost rectifier, operating in critical conduction mode, using a non-dissipative commutation cells and frequency modulation. The digital control has been developed using a hardware description language (VHDL) and implemented using the XC2S200E-SpartanII-E/Xilinx FPGA, performing a true critical conduction operation mode for a generic number of interleaved cells. Experimental results are presented, in order to verify the feasibility and performance of the proposed digital control, through the use of a Xilinx FPGA device.
Resumo:
A microactuator made from poly(vinylidene fluoride) (PVDF), a piezoelectric polymer, was fabricated to control the gas flow rate through a glass micronozzle. The actuator was formed by gluing together two PVDF sheets with opposite polarization directions. The sheets were covered with thin conducting films on one side, that were then used as electrodes to apply an electric field to move the valve. The actuator has a rectangular shape, 3 mm x 6 mm. The device was incorporated with a micronozzle fabricated by a powder blasting technique. Upon applying a DC voltage across the actuator electrodes, one sheet expands while the other contracts, generating an opening motion. A voltage of +300 V DC was used to open the device by moving the actuator 30 mu m, and a voltage of -200 V DC was used to close the device by moving the actuator 20 mu m lower than the relaxed position. Flow measurements were performed in a low-pressure vacuum system, maintaining the microvalve inlet pressure constant at 266 Pa. Tests carried out with the actuator in the open position and with a pressure ratio (inlet pressure divided by outlet pressure) of 0.5, indicated a flow rate of 0.36 sccm. In the closed position, and with a pressure ratio of 0.2, a flow rate of 0.32 sccm was measured.
Resumo:
A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.