103 resultados para sonar transducers
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fast, selective, reproducible and reliable detections have been carried out by using enzymatic biosensors in several areas. The enzymatic biosensors based on the inhibition represent an important role in analytical chemistry. Enzymes like cholinesterases, peroxidases, tyrosinases, etc. have been immobilized on electrochemical and optical transducers and the enzymatic activity decreasing in the presence of the inhibitor is related with its concentrations. This article presents a review on the enzymes used on the construction of these sensors, emphasizing the respective applications.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The modified Cam - Clay model was used to model experimental results of a saturated residual sandy soil from Sao Carlos - SP. Triaxial compression tests were performed using Bishop - Wesley cell with internal transducers to measure axial and radial strains. It was observed that the model fairly fitted experimental results, specially the principal stress difference at critical state. In general it was observed a good qualitative agreement between experimental and predicted strain values, considering compression or expansion of the samples. However, in all the stress path used, but 100 degrees and 140 degrees, the model yielded strains larger than that measured in the tests.
Resumo:
The J(1)...J(3) is a recent optical method for linear readout of dynamic phase modulation index in homodyne interferometers. In this work, the J(1)... J(3) method is applied to measure voltage in an optical voltage sensor. Based on the classical J(1)...J(4) method, the J(1)... J(3) technique shows to be more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is enhanced. The agreement between theoretical and experimental results, based on 1/f noise, is demonstrated.
Resumo:
This report describes the pathologic findings in a single, adult female Cuvier's beaked whale Ziphius cavirostris stranded in the Canary Islands. The study indicated that this whale died with a severe, systemic, herpesviral infection and clearly exhibited lesions different from those of the fat and gas embolic syndrome described in beaked whale mass strandings associated with sonar exposure. This is the first report of a cetacean alphaherpesvirus infection of the lymphoid system in a beaked whale.
Resumo:
A measurement device has been developed to measure force and torque components acting on the impeller of a model pump-turbine, which uses crystal quartz load transducers installed on the rotating shaft. These kinds of load transducers allow greater stiffness than arrangements using strain gauges. Therefore, the dynamics behavior of the measurement device has to be taken into account. Some results of measurements are present in the whole operating range of model pump-turbine.
Resumo:
Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.
Resumo:
Atherosclerosis is a very common and important disease being the most important cause of mortality in Brazil. Indeed, in 1995, 23.3% of deaths, all ages, in our country, were the consequence of atherosclerosis. This percentage grows to 26.3% for S. Paulo and 32.7% for Rio Grande do Sul. Morphologically, there are 3 main types of lesions: fatty streaks, fibrous plaques, and complicated lesions. Fatty streaks are inocuous and occur early in life. In some persons, with age, they change into fibrous plaques that may lead to stenosis. They also may become complicated by erosion, calcification, hemorrhage and thrombosis. Atherosclerosis is initiated by endothelial functional alterations responsible for increase in permeability to macromolecules, adhesion, and migration of monocytes-macrophages and lymphocytes plus recruitment of platelets and smooth-muscle medial cells. Adhesion molecules, cytokines, growth factors, and free radicals are locally synthesized, favoring proliferation of extracellular matrix and progression of the lesion. Experimental, clinical, and epidemiological evidence point to the importance of lipids, mainly cholesterol-rich low-density lipoprotein (LDL), as one of the most important molecules involved in the genesis and progression of atherosclerosis. Patients with a genetic disorder of cholesterol metabolism (familial hyperlipidemia), caused by a decrease in the availability of receptors for LDL, develop severe atherosclerosis early in life. A series of other factors, such as age, diabetes melitus, diet, hypertension, lack of exercise, elevated hemocysteinemia, immunological disorders, and coagulation instability, are related to the progression of atherosclerosis. All of them are capable of altering the endothelium or increasing the offer of LDL. All the above-mentioned factors are systemic; but atherosclerosic lesions are focal, located at preferential sites such as the emergence of colaterals, bifurcations, and curvatures of arteries, all areas in which the laminar flow is disturbed. In these areas shear stress is diminished favoring the prolongation of permanence time of lipid particles, cells, cytokines, growth factors, etc., in the vicinity of the endothelium. Moreover, the endothelium has sensors that act as transducers of mechanical forces in biological responses. Experimental data demonstrate that the number and quality of adhesion molecules, cytokines, and growth factors synthetized, as well as the local production of radicals, and pro and anticoagulation factors may change with shear stress favoring or not the local establishment and progression of atherosclerotic lesions.
Resumo:
Measurements of ultrasonic attenuation and velocity in milk and low concentration water-in-oil (W/O) emulsion were conducted, using a measurement cell with a double-element transducer that eliminates diffraction losses. The milk is characterized by the attenuation coefficient, while in the case of water-in-oil emulsions, the characterization is best represented by the propagation velocity.