59 resultados para solid sampling technique
Resumo:
A general technique to embed non-uniform displacement discontinuities into standard solid finite elements is presented. The technique is based on the decomposition of the kinematic fields into a component related to the deformation of the solid portion of the element and one related to the rigid-body motion due to a displacement discontinuity. This decomposition simplifies the incorporation of discontinuity interfaces and provides a suitable framework to account for non-uniform discontinuity modes. The present publication addresses two families of finite element formulations: displacement-based and stress hybrid finite element. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
Mangrove swamps are found in estuaries along the coastal plains of tropical regions and have be subjected to heavy occupation and use pressure due to their privileged locations and abundance of biological resources. The present work evaluated the ecological characteristics and solid wastes accumulated in eight areas along the Santos - Sao Vicente Estuary Complex. The superficially deposited residues at each sampling site were collected and subsequently washed, drained, counted, weighed and separated into classes according to their composition and predominant use. The predominant litter type in terms of density was plastic (62.81%) and, by weight, wood (55.53%). The greatest deposition of residues was associated with areas that were less inclined and that had low plant density levels, indicating that the presence of obstacles was not critical for retaining floating residues in mangrove areas. The presence of the most frequently encountered types of solid waste residues could be explained by local activities. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
O objetivo deste trabalho foi analizar a distribuição espacial da compactação do solo e a influência da umidade do solo na resistência à penetração. Esta última variável foi descrita pelo índice de cone. O solo estudado foi Nitossolo e os dados de índice de cone foram obtidos usando um penetrômetro. A resistência do solo foi avaliada a 5 profundidades diferentes, 0-10 cm, 10-20 cm, 20-30 cm, 30-40 cm e mais de 40 cm, porém o conteúdo de umidade do solo foi medido a 0-20 cm e 20-40 cm. As condições hídricas do solo variaram nas diferentes amostragems. Os coeficientes de variação para o índice de cone foram 16,5% a 45,8% e os do conteúdo de umidade do solo variaram entre 8,96% e 21,38%. Os resultados sugeriram elevada correlação entre a resistência do solo, estimada pelo índice de cone e a profundidade do solo. Sem embargo, a relação esperada com a umidade do solo não foi apreciada. Observou-se dependência espacial em 31 de 35 séries de dados de índice de cone e umidade do solo. Esta dependência foi ajustada por modelos exponenciais com efeito pepita variável de 0 a 90% o valor do patamar. em séries de dados o comportamento foi aleatório. Portanto, a técnica das distâncias inversas foi utilizada para cartografar a distribuição das variáveis que não tiveram estrutura espacial. Na krigagem constatou-se uma suavização dos mapas comparados com esses das distâncias inversas. A krigagem indicadora foi utilizada para cartografar a variabilidade espacial do índice de cone e recomendar melhor manejo do solo.
Resumo:
Cells of Mikania glomerata, Cephaelis ipecacuanha and Maytenus aquifolia were co-cultured in a two-phase system using filter paper as a solid support. The species were co-cultured in all possible paired combinations. Interaction between Mikania and Maytenus cells resulted in increased biomass production of Maytenus cells, but the friedelin content was reduced. Co-cultivation of Cephaelis and Mikania cells enhanced coumarin content, but inhibited the growth of Mikania cells. However, yield of emetine as well as Cephaelis biomass accumulation were positively stimulated by the co-cultivation. Results indicate a possible occurrence of allelopathy in such a system.
Two-colour photocurrent detection technique for coherent control of a single InGaAs/GaAs quantum dot
Resumo:
We present a two-colour photocurrent detection method for coherent control of a single InGaAs/GaAs self-assembled quantum dot. A pulse shaping technique provides a high degree of control over picosecond optical pulses. Rabi rotations on the exciton to biexciton transition are presented, and fine structure beating is detected via time-resolved measurements. (c) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes the effect of nitrogen Plasma Immersion Ion Implantation (PIII) on chemical structure, refraction index and surface hardness of plasma-polymerized hexamethyldisilazane (PPHMDSN) thin films. Firstly, polymeric films were deposited at 13.56 MHz radiofrequency (RF) Plasma Enhanced Chemical Vapour Deposition (PECVD) and then, were treated by nitrogen PIII from 15 to 60 min. Fourier Transformed Infrared (FTIR) spectroscopy was employed to analyse the molecular structure of the samples, and it revealed that vibrations modes at 3350 cm(-1), 2960 cm(-1), 1650 cm(-1), 1250 cm(-1) and 1050 cm(-1) were altered by nitrogen PIII. Visible-ultraviolet (vis-UV) spectroscopy was used to evaluate film refractive index and the results showed a slight increase from 1.6 to 1.8 following the implantation time. Nanoindentation revealed a surface hardness rise from 0.5 to 2.3 GPa as PIII treatment time increased. These results indicate nitrogen PIII is very promising in improving optical and mechanical properties of PPHMDSN films.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The recovery of the pharmaceuticals bezafibrate and tetracycline from water was evaluated, using Solid Phase Extraction (SPE) with the aim of applying this technique to interrupt the pharmaceuticals' photodegradation by photo-Fenton process for further analysis. Sep-Pack C-18, Strata X, and Oasis HLB cartridges were evaluated. Oasis HLB showed the most satisfactory recovery and repeatability results: 98% (CV - 1%) for bezafibrate (20.0 mg L-1) and 76% (CV = 1%) for tetracycline (25.0 mg L-1). There was not a significant decrease in recovery at lower concentrations of the pharmaceuticals, and neither when present in Sewage Treatment Plant (STP) effluent matrix.
Resumo:
Different geoenvironmental site investigation techniques to assess contamination from a municipal solid waste disposal site in Brazil are presented here. Superficial geophysical investigation (geoelectrical survey), resistivity piezocone penetration tests (RCPTU), soil samples collected with direct-push samplers and water samples collected from monitoring wells were applied in this study. The application of the geoelectrical method was indispensable to identify the presence and flow direction of contamination plumes (leachate) as well as to indicate the most suitable locations for RCPTU tests and soil and water sampling. Chemical analyses of groundwater samples contributed to a better understanding of the flow of the contaminated plume. The piezocone presented some limitations for tropical soils, since the groundwater level is sometimes deeper than the layer which is impenetrable to the cone, and the soil genesis and unsaturated conditions affect soil behavior. The combined interpretation of geoelectrical measurements and soil and water samplings underpinned the interpretation of RCPTU tests. The interpretation of all the test results indicates that the contamination plume has already overreached the landfill's west-northwest borders. Geoenvironmental laboratory test results suggest that contamination from the solid waste disposal site has been developing gradually, indicating the need for continuous monitoring of the groundwater.
Resumo:
We report the preparation and characterization of yttria-stabilized zirconia/nickel oxide composites (YSZ/NiO). This composite is the precursor material of the cermet YSZ/Ni, which is used as solid oxide fuel cell anode material. The performance of the anode is strongly dependent on the microstructural properties of the cermet. Therefore, the control of the microstructure of the YSZ/NiO composite is a key step for the fabrication of high-performance anodes. In this study, the composites were prepared by a modified liquid mixture technique. Scanning electron microscopy analysis evidenced the good dispersion of the phases and that NiO nanoparticles are spread over the YSZ surface. Sintered pellets were studied by X-ray diffraction and impedance spectroscopy. The main results show that the composite is comprised of a well-dispersed mixture of the two phases. The electrical conductivity data show that there is a strong dependence of the transport mechanism on the relative composition of phases. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A comparative study is reported between C-18 bonded silica gel and powdered polyethylene (PE) as sorbent for Cd, Cu, and Pb determination using ammonium diethyldithiophosphate (ADTP) as the complexing agent in a flow injection system. The complexes were formed in 0.14 mol L-1 HNO3 and processed in a simple flow system comprising a peristaltic pump, a manual injector-commutator, and a sorbent-packed minicolumn. Ethanol was selected as the eluent and analytes in the eluate were determined by flame atomic absorption spectrometry. The optimum concentration of the complexing agent was 0.1% (m/v) ADTP for Cu and Pb determination using either C-18 or PE, and 0.25% (m/v) ADTP for Cd determination using PE. The sample loading flow rates were 5.0, 3.6, and 3.0 mL min(-1) for Cu, Pb, and Cd, respectively. The best elution flow rate was 6.5 mL min(-1). For a 60-sec preconcentration time, the sampling rate was 40 h(-1) and the enrichment factors of 33, 36, and 11 times (C-18) or 18, 22, and 23 times (PE) were obtained for Cu, Pb, and Cd, respectively. The limits of detection (LOD) were 1.6 mug L-1 Cu, 11 mug L-1 Pb, and 2.0 mug L-1 Cd using C-18 or 2.9 mug L-1 Cu, 19 mug L-1 Pb, and 1.0 mug L-1 Cd using PE, respectively. The relative standard deviations (n = 12) were typically <2%, <2%, and <6% for Cd, Cu, and Pb, respectively. The recoveries of Cd, Cu, and Pb added to wine samples varied from 96-99%, 97-102%, and 90-99%, respectively, using C-18 or PE. Accuracy was checked for Cd, Cu, and Pb determination in six wine samples digested by block digestor and open-vessel microwave-assisted digestion systems. The results revealed that C-18 was more efficient for Cu and Pb determination, while PE was the best sorbent for Cd.