92 resultados para software distribution in using status
Resumo:
Purpose: To evaluate the stress distribution in peri-implant bone by simulating the effect of an implant with microthreads and platform switching on angled abutments through tridimensional finite element analysis. The postulated hypothesis was that the presence of microthreads and platform switching would reduce the stress concentration in the cortical bone. Methods: Four mathematical models of a central incisor supported by an implant (5.0mm×13mm) were created in which the type of thread surface in the neck portion (microthreaded or smooth) and the diameter of the angled abutment connection (5.0 and 4.1mm) were varied. These models included the RM (regular platform and microthreads), the RS (regular platform and smooth neck surface), the SM (platform switching and microthreads), and the SS (platform switching and smooth neck). The analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). An oblique load (100N) was applied to the palatine surface of the central incisor. The bone/implant interface was considered to be perfectly integrated. Values for the maximum (σmax) and minimum (σmin) principal stress, the equivalent von Mises stress (σvM), and the maximum principal elastic strain (e{open}max) for cortical and trabecular bone were obtained. Results: For the cortical bone, the highest σmax (MPa) were observed for the RM (55.1), the RS (51.0), the SM (49.5), and the SS (44.8) models. The highest σvM (MPa) were found for the RM (45.4), the SM (42.1), the RS (38.7), and the SS models (37). The highest values for σmin were found for the RM, SM, RS and SS models. For the trabecular bone, the highest σmax values (MPa) were observed in the RS model (6.55), followed by the RM (6.37), SS (5.6), and SM (5.2) models. Conclusion: The hypothesis that the presence of microthreads and a switching platform would reduce the stress concentration in the cortical bone was partially rejected, mainly because the microthreads increased the stress concentration in cortical bone. Only platform switching reduced the stress in cortical bone. © 2012 Japan Prosthodontic Society.
Resumo:
Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA). Four mathematical models (M) of a mandibular hemiarch simulating various alveolar ridge shapes (1-distal desceding, 2- concave, 3-horizontal and 4-distal ascending) were built. Tooth 33 was placed as the abutment. Two RPDs, one supported by tooth and fibromucosa (MB) and other one supported by tooth and implant (MC) were simulated. MA was the control (no RPD). The load (50N) were applied simultaneously on each cusp. Appropriate boundary conditions were assigned on the border of alveolar bone. Ansys 10.0 software was used to calculate the stress fields and the von Mises equivalent stress criteria (σvM) was applied to analyze the results. The distal ascending shape showed the highest σvM for cortical and medullar bone. The alveolar ridge shape had little effect on changing the σvM based on the same prosthesis, mainly around the abutment tooth.
Resumo:
Herbicides application success depends, besides product correct choice, the observation of environmental conditions and application quality. The work aimed to quantify the effects of surfactant addition in spraying solution, in natural and artificial targets, associated to different nozzle boom angles in relation to application offset, by using distinct evaluation methods. Two experiments were conducted at NuPAM-FCA/UNESP, Botucatu County, São Paulo State, constituted by ten treatments, in factorial scheme 2 × 5, corresponding to two spraying solutions conditions (absence or presence of Aterbane BRTM (0.25% v/v) adjuvant) and five angles of spray nozzle in relation to offset application (-30°, -15°, 90°, +15° and +30°). In Ipomea grandifolia leaves, the distribution and drops deposition of a tracer solution were evaluated by using scores visual and spectrophotometer process. In hydro sensible papers, volumetric medium diameter (VMD), density (cm2 ) and drops medium diameter, covered area (%) and application fees (L ha-1) were evaluated through e-SprinkleTM software. Aterbane BRTM (0.25% v/v) presence or absence, associated or no, to spray nozzles offset did not provide significant differences in I. grandifolia spray deposition. The use of artificial targets presented applicative technical limitations in relation to the use of natural ones as study matrix. Deposit and distribution variables esteem distinct behaviours, independent of target nature.
Resumo:
Bats are main reservoirs for Lyssavirus worldwide, which is an important public health issue because it constitutes one of the big challenges in rabies control. Yet, little is known about how the virus is maintained among bats, and the epidemiological relationships remain poorly understood. The aim of the present study was to investigate the distribution of the rabies virus (RABV) in bat tissues and organs and to genetically characterize virus isolates from naturally infected non-hematophagous bats. The heminested reverse transcriptase polymerase chain reaction (hnRT-PCR) and sequencing using primers to the nucleoprotein coding gene were performed. The results showed a dissemination of the RABV in different tissues and organs, particularly in the salivary glands, tongue, lungs, kidneys, bladder, intestine and feces, suggesting other possible forms of RABV elimination and the possibility of transmission among these animals. The phylogenetic analysis confirmed that different variants of RABV are maintained by non-hematophagous bats in nature and have similar tissue distribution irrespective of bat species and phylogenetic characterization. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.
Resumo:
Purpose: This three-dimensional finite element analysis study evaluated the effect of different material combinations on stress distribution within metal-ceramic and all-ceramic single implant-supported prostheses. Materials and Methods: Three-dimensional finite element models reproducing a segment of the maxilla with a missing left first premolar were created. Five groups were established to represent different superstructure materials: GP, porcelain fused to gold alloy; GR, modified composite resin fused to gold alloy; TP, porcelain fused to titanium; TR, modified composite resin fused to titanium; and ZP, porcelain fused to zirconia. A 100-N vertical force was applied to the contact points of the crowns. All models were fixed in the superior region of bone tissue and in the mesial and distal faces of the maxilla section. Stress maps were generated by processing with finite element software. Results: Stress distribution and stress values of supporting bone were similar for the GP, GR, TP, and ZP models (1,574.3 MPa, 1,574.3 MPa, 1,574.3 MPa, and 1,574.2 MPa, respectively) and different for the TR model (1,838.3 MPa). The ZP model transferred less stress to the retention screw (785 MPa) than the other groups (939 MPa for GP, 961 MPa for GR, 1,010 MPa for TP, and 1,037 MPa for TR). Conclusion: The use of different materials to fabricate a superstructure for a single implant-supported prosthesis did not affect the stress distribution in the supporting bone. The retention screw received less stress when a combination of porcelain and zirconia was used. Int J Oral Maxillofac Implants 2011;26:1202-1209
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Substrate distribution was studied in three adult colonies of the leaf-cutting ant Atta bisphaerica Forel, 1908 using dye. Some supply holes were mapped using baits made from small plastic straws impregnated with citric pulp. Two holes, equidistant from one another, were then selected in each nest. The colonies were excavated completely 24 h after bait placement. During excavation, fungus chambers were checked for dye. We observed that the dyed baits were distributed in all sectors and at all depths regardless of where the baits had been placed. This supported the hypothesis that toxic baits placed in a single supply hole are uniformly distributed throughout the colony.
Resumo:
Cytochemical studies were carried out to establish lipid distribution in the salivary glands of larvae and adult bees, using the imidazole buffer technique. In the duct cells of the larval salivary gland, the reaction was positive in the epicuticle and negative in the glandular lumen. The absence of smooth endoplasmic reticulum and the presence of lipids in the intercellular space suggest that lipids absorbed from the haemolymph could be used in the constitution of the epicuticle, after having been conveyed through the epithelium. In adult workers (new-emerged, nurse and forager workers), the head salivary glands presented a positive reaction in the secretion in glandular lumen, identifying its lipidic nature.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)