101 resultados para signal processing program


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate data acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. Many statistics have shown effective to detect burn, such as the root mean square (RMS), correlation of the AE, constant false alarm (CFAR), ratio of power (ROP) and mean-value deviance (MVD). However, the CFAR, ROP, Kurtosis and correlation of the AE have been presented more sensitive than the RMS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esse trabalho tem por objetivo o desenvolvimento de um sistema inteligente para detecção da queima no processo de retificação tangencial plana através da utilização de uma rede neural perceptron multi camadas, treinada para generalizar o processo e, conseqüentemente, obter o limiar de queima. em geral, a ocorrência da queima no processo de retificação pode ser detectada pelos parâmetros DPO e FKS. Porém esses parâmetros não são eficientes nas condições de usinagem usadas nesse trabalho. Os sinais de emissão acústica e potência elétrica do motor de acionamento do rebolo são variáveis de entrada e a variável de saída é a ocorrência da queima. No trabalho experimental, foram empregados um tipo de aço (ABNT 1045 temperado) e um tipo de rebolo denominado TARGA, modelo ART 3TG80.3 NVHB.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Condition monitoring is used to increase machinery availability and machinery performance, reducing consequential damage, increasing machine life, reducing spare parts inventories, and reducing breakdown maintenance. An efficient real time vibration measurement and analysis instruments is capable of providing warning and predicting faults at early stages. In this paper, a new methodology for the implementation of vibration measurement and analysis instruments in real time based on circuit architecture mapped from a MATLAB/Simulink model is presented. In this study, signal processing applications such as FIR filters and fast Fourier transform are treated as systems, which are implemented in hardware using a system generator toolbox, which translates a Simulink model in a hardware description language - HDL for FPGA implementations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents recent improvements in a density measurement cell with a double-element transducer that can eliminate diffraction effects. A new mechanical design combined with the use of more appropriate materials has resulted in better parallelism between interfaces, more robust assembly, and chemical resistance. A novel method of signal processing, named energy method, is introduced to obtain the reflection coefficient, reducing sensitivity to noise and improving accuracy. The measurement cell operation is verified both theoretically, using an acoustic wave propagation model, and experimentally, using homogeneous liquids with different densities. The accuracy in the density measurement is 0.2% when compared with the measurements made with a pycnometer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of strategies for structural health monitoring (SHM) has become increasingly important because of the necessity of preventing undesirable damage. This paper describes an approach to this problem using vibration data. It involves a three-stage process: reduction of the time-series data using principle component analysis (PCA), the development of a data-based model using an auto-regressive moving average (ARMA) model using data from an undamaged structure, and the classification of whether or not the structure is damaged using a fuzzy clustering approach. The approach is applied to data from a benchmark structure from Los Alamos National Laboratory, USA. Two fuzzy clustering algorithms are compared: fuzzy c-means (FCM) and Gustafson-Kessel (GK) algorithms. It is shown that while both fuzzy clustering algorithms are effective, the GK algorithm marginally outperforms the FCM algorithm. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosus-ceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of Tc-99m and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we deal with the problem of feature selection by introducing a new approach based on Gravitational Search Algorithm (GSA). The proposed algorithm combines the optimization behavior of GSA together with the speed of Optimum-Path Forest (OPF) classifier in order to provide a fast and accurate framework for feature selection. Experiments on datasets obtained from a wide range of applications, such as vowel recognition, image classification and fraud detection in power distribution systems are conducted in order to asses the robustness of the proposed technique against Principal Component Analysis (PCA), Linear Discriminant Analysis (LDA) and a Particle Swarm Optimization (PSO)-based algorithm for feature selection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work was to demonstrate that is possible to monitor the disintegration process of film-coated magnetic tablets by multi-sensor alternate current Biosusceptometry (ACB) in vivo and in vitro. This method is based on the recording of signals produced by the magnetic tablet using a seven sensors array and signal-processing techniques. The disintegration was confirmed by signals analysis in healthy human volunteers' measurements and in vitro experiments. Results showed that ACB is efficient to characterize the disintegration of dosage forms in the stomach, being a research tool for the development of new pharmaceutical dosage forms. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper provides an insight to the trade-off between settling time and power consumption in regulated current mirrors as building parts in micropower current-switching D/A converters. The regulation-loop frequency characteristic is obtained and difficulties to impose a dominant-pole condition to the resulting 2nd-order system are evaluated. Raising pole frequencies in micropower circuits, while meeting consumption requirements, is basically limited by parasitic capacitances. For such cases, an alternative is to impose a twin-pole condition in which design constraints are somewhat relieved and settling slightly improved. Relationships between pole frequencies, transistor geometry and bias are established and design guidelines for regulated current mirrors founded. By placing loop-transistors in either weak or strong inversion, small (W/L) ratios are allowed and stray capacitances reduced. Simulated waveforms suggest a good agreement with theory. The proposed approach applied to the design of a micropower current-mode D/A converter improves both simulated and experimental settling performance.