38 resultados para reproducibility
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJETIVO: Estudar a confiabilidade, da versão em português, do questionário para o diagnóstico psicológico e psicossocial dos indivíduos com desordens temporomandibulares (RDC/TMD). MÉTODOS: Foram entrevistados 109 indivíduos, de ambos sexos, que demandaram atendimento junto à Clínica de Fisioterapia do Centro Universitário de Araraquara, de janeiro a julho de 2006. Os questionários foram aplicados por um único examinador. Após duas semanas, o mesmo foi reaplicado em 36 indivíduos. Para avaliação da consistência interna do método, utilizou-se o Coeficiente Alfa de Cronbach; para análise da reprodutibilidade intra-examinador, o Coeficiente de Correlação Intraclasse (ro) e a estatística Kappa (kapa), respectivamente às variáveis de natureza quantitativa e qualitativa. RESULTADOS: A consistência interna para as dimensões intensidade da dor crônica e incapacidade; limitação da função mandibular; sintomas físicos não-específicos, incluindo os itens de dor; sintomas físicos não-específicos, excluindo os itens de dor e depressão foi de 0,8479, 0,8971, 0,8673, 0,8080 e 0,9270 respectivamente, atestando ao método excelente validade interna. Obteve-se excelente concordância intra-examinador para as questões referentes ao tempo de presença da dor e sua gradação, e boa para a questão referente à dor presente. Os menores valores de kapa relacionaram-se aos itens de sintomas físicos e depressão. A percepção de estalos ou rangidos pelos indivíduos apresentou concordância regular bem como a questão referente à procura de profissional para tratamento da dor. As demais questões apresentaram reprodutibilidade boa e ótima, sendo que a maioria dessas apresentou nível máximo de concordância. CONCLUSÃO: A versão adaptada para o português mostrou-se confiável para detecção das alterações psicológicas e psicossociais associadas às desordens temporomandibulares.
Off line extraction of phenol from human urine sample with isoamyl alcohol and determination by HPLC
Resumo:
This method has been developed for extraction and determination of phenol in a urine sample by high performance liquid chromatography.After acid hydrolysis, the free phenol was extracted with isoamyl alcohol solvent, followed by back extraction with 0.5 mol.L-1 sodium hydroxide solution and analyzed by an isocratic HPLC Varian System, equipped with reverse-phase column (MicroPak-C-18). The mobile phase was acetonitrile in 0.01 mol.L-1 hydrochloric acid solution, (20:80 v/v), and at a now-rate of 1.0 mL.min-1. The chromatogram was monitored at 220 nm in room temperature. The identification was based on retention time and the quantification was performed by automatic peak-area determination, corrected for the external standards method.The recovery was higher than 99.5 % for phenol and reproducibility of method was shown to be 2.3% standard deviation and 5.6% coefficient of variance (n=20). The limit detection was 0.05 mgL(-1) and a range of 0.05 to 20.0 mgL(-1) of phenol for linearity.
Resumo:
We are presenting here p/n junctions obtained with a modified opened liquid-phase epitaxy (LPE) system, used to diffuse indium antimonide (InSb) doped with Cd over InSb doped with Te wafers, in order to make InSb infrared (IR) sensors. This technique has several advantages: the diffusion can be performed in bigger substrate areas improving the device production; this method decreases the device manipulation, decreasing human mistakes and increasing the process reproducibility. The opened LPE in this work produced sensors in the first case with vapor of the diffusion material, coming from a microholed carbon boat full of the diffusion material, over which is positioned the substrate at atmospheric pressure. In the second, the diffusion material is on the bottom of a quartz recipient, and the InSb/Te wafer works as its cover, and vacuum was used. The IR sensors produced with the first method measured 8.9 x 10(7) cm Hz(1/2)/W as detectivity value and higher IR spectral response at 4.6 mu m, and those produced with the second 2.8 x 10(9) cm Hz(1/2)/W, at 4.4 mu m. Besides the electrical-optical properties, the structural properties of diffused layers were investigated by X-ray diffraction (XRD), scanning electron and atomic force microscopy (SEM, AFM), energy-dispersive and secondary ion mass spectroscopy (EDS, SIMS). (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fiber reinforced polymer composites have been widely applied in the aeronautical field. However, composite processing, which uses unlocked molds, should be avoided in view of the tight requirements and also due to possible environmental contamination. To produce high performance structural frames meeting aeronautical reproducibility and low cost criteria, the Brazilian industry has shown interest to investigate the resin transfer molding process (RTM) considering being a closed-mold pressure injection system which allows faster gel and cure times. Due to the fibrous composite anisotropic and non homogeneity characteristics, the fatigue behavior is a complex phenomenon quite different from to metals materials crucial to be investigated considering the aeronautical application. Fatigue sub-scale specimens of intermediate modulus carbon fiber non-crimp multi-axial reinforcement and epoxy mono-component system composite were produced according to the ASTM 3039 D. Axial fatigue tests were carried out according to ASTM D 3479. A sinusoidal load of 10 Hz frequency and load ratio R = 0.1. It was observed a high fatigue interval obtained for NCF/RTM6 composites. Weibull statistical analysis was applied to describe the failure probability of materials under cyclic loads and fractures pattern was observed by scanning electron microscopy. (C) 2010 Published by Elsevier Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The thermoluminescence (TL) response of Dy and Li doped 20CaB(4)O(7)-80CaB(2)O(4) (Wt%) glass-ceramic irradiated with ultraviolet (UV) radiation was studied. In order to act as TL activator ions, the Dy and Li ions were included in the matrix during the melting process to increase its TL efficiency. A single crystalline CaB2O4 phase was present in the glass-ceramic as determined by X-ray diffraction (XRD). The glass-ceramic 20CaB(4)O(7)-80CaB(2)O(4):Dy,Li wt% (named 20CBO7:Dy,Li) is a newly prepared TL material. Its thermoluminescent dosimetric characteristics have shown a linear response under UV radiation exposure and a good TL signal reproducibility, thus proving to be a promising material for using as an ultraviolet radiation dosimeter. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
INTRODUÇÃO: O ensaio do cometa ou técnica da eletroforese de células isoladas é largamente empregado para avaliação de danos e reparo do DNA em células individuais. O material pode ser corado por técnicas de fluorescência ou por sal de prata. Este último apresenta vantagens técnicas, como o tipo de microscópio utilizado e a possibilidade de armazenamento das lâminas. A análise dos cometas pode ser feita de modo visual, porém há a desvantagem da subjetividade dos resultados, que pode ser minimizada por análise digital automatizada. OBJETIVOS: Desenvolvimento e validação de método de análise digital de cometas corados por sal de prata. MÉTODOS: Cinquenta cometas foram fotografados de maneira padronizada e impressos em papel. Além de medidas manualmente, essas imagens foram classificadas em cinco categorias por três avaliadores, antes e depois de pré-processadas automaticamente pelo software ImageJ 1.38x. As estimativas geradas pelos avaliadores foram comparadas quanto sua correlação e reprodutibilidade. em seguida, foram desenvolvidos algoritmos de análise digital das medidas, com base em filtros estatísticos de mediana e de mínimo. Os valores obtidos foram comparados com os estimados manual e visualmente após o pré-processamento. RESULTADOS: As medidas manuais das imagens pré-processadas apresentaram maior correlação intraclasse do que as imagens preliminares. Os parâmetros automatizados apresentaram alta correlação com as medidas manuais pré-processadas, sugerindo que este sistema aumenta a objetividade da análise, podendo ser utilizado na estimativa dos parâmetros dos cometas. CONCLUSÃO: A presente análise digital proposta para o teste do cometa corado pela prata mostrou-se factível e de melhor reprodutibilidade que a análise visual.