271 resultados para radiographic vertebral fracture


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Crown-root fractures account for 5% of all fractures in permanent teeth and can involve enamel, dentin, and cementum. Depending on whether there is pulpal involvement, these problems may be classified as complicated (which are more common) or noncomplicated. The treatment depends on the level of the fracture line, root length and/or morphology, and esthetic needs. Several treatment strategies are available for esthetic and functional rehabilitation in crown-root fractures. Adhesive tooth fragment reattachment is the most conservative restorative option when the tooth fragment is available and the biological width has no or minimal violation. This article reports a case of an uncomplicated crown-root fracture in the permanent maxillary right central incisor of a young patient who received treatment with adhesive tooth fragment reattachment, preserving the anatomic characteristics of the fractured tooth after periodontal intervention. The fracture line of the fragment had an unusual shape, starting on the palatal side and extending to the buccal side subgingivally. After 7 years, the attached coronal fragment remained in position with good esthetics, as well as clinical and radiographic signs of pulpal vitality, periodontal health, and root integrity, thus indicating success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos). Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8); fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8). Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz) de baixa intensidade (30mW cm-2), aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (P<0,001 e alfa=0,05) entre as médias dos parâmetros de tempo para consolidação óssea observadas nos animais dos grupos tratado (média de 67,5 dias) e controle (média de 106 dias). Este protocolo de estimulação ultra-sônica promoveu sinais clínicos e radiográficos acelerados da consolidação óssea nas fraturas tratadas. Os resultados deste estudo sugerem que o ultra-som pulsado de baixa intensidade pode ser indicado como terapia adjuvante de fraturas diafisárias recentes em cães.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os achados clínicos e radiográficos após reparo intra-articular do ligamento cruzado cranial com prótese de poliéster, utilizando a técnica over-the-top modificada, foram avaliada em seis cães. Sete cirurgias foram realizadas devido ao acometimento bilateral em um dos animais. A avaliação clínica foi realizada ao 3º, 10º e 40º dias de pós-operatório, e a avaliação radiográfica realizada ao 5º e 24º meses após a cirurgia em cinco cães, por meio da qual se confirmou a progressão da doença articular degenerativa. A resolução dos sinais clínicos foi observada entre o 25º e 68º dias após a cirurgia, segundo avaliação realizada pelos proprietários. A função do membro operado foi considerada boa. Dois cães apresentaram desgaste e ruptura da prótese após a cirurgia. Concluiu-se que a prótese de poliéster, da forma como foi implantada neste estudo, não pode ser considerada como substituto satisfatório, uma vez que resultados superiores podem ser obtidos com ténicas menos invasivas e mais simples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doria, R.G.S.; Canola, P.A.; Freitas, S.H. & Canola, J.C. [Equine chronic proliferative synovitis (villonodular synovitis): clinical, radiographic and ultrasonographic aspects: Relate of case.] Sinovite proliferativa cronica (sinovite vilonodular) em equino: aspectos clinicos, radiograficos e ultra-sonograficos: Relato de caso. Revista Brasileira de Medicina Veterinciria 30(3):157-161, 2008. Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Cuiaba, UNIC, Av. Antartica 788, Casa 26, Residencial Villas Boas, Ribeirao da Ponte, Cuiaba, MT 78040-500. Brasil. E-mail: redoria@uol.com.brThe development of intracapsullar masses at the dorsal aspect of the metacarpofalangeal joint for a period of several months is commonly secondary to the chronic synovitis. Although it is known as villonodular synovitis in horses probably is better to refer it as chronic proliferative synovitis. The most common causes are the non-treated osteocondral fractures of the dorsal portion of the proximal phalanx. In addition, the development of villonodular masses follows the degenerative process in the joint. A case of a lame animal is reported at the present study. The correct diagnosis and the adequate therapeutic propositions were given based on the clinical examination, therapeutic local-anesthetic test and radioghaphic and ultrasonographic imaging exams. The development of a criterious identification of this disease must be based on clinical findings, radiographic and ultrasonographic exams which assume fundamental importance to the treatment and prognostic. The aim of this study is to describe the clinical, radiographic and ultrasonographic findings' allowing the identification and diagnosis of chronic proliferative synovitis at the thoracic metacarpofalangeal joint in the horse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os objetivos do estudo foram avaliar o alinhamento, no plano sagital, da coluna de indivíduos com alterações na medida da gibosidade, comparando com um grupo sem alterações; testar a confiabilidade do instrumento utilizado e verificar se existem correlações entre as medidas da gibosidade e os valores das curvaturas vertebrais. Foram avaliados 40 jovens, divididos em grupo controle - ausência ou presença de gibosidades inferiores a 0,5 cm na curvatura torácica e 0,7 cm na lombar (n=20) e, grupo experimental - gibosidades superiores às descritas (n=20). A gibosidade e as curvaturas no plano sagital foram mensuradas com um instrumento adaptado a um nível d'água e o teste de Adams. As coletas foram realizadas em duas datas distintas, nos dois grupos. Após aplicação do teste Mann-Whitney não foi encontrada diferença entre as ocasiões de coletas e, emparelhando-se os grupos, foi encontrada diferença apenas na medida cervical. Na verificação de existência de relação entre as medidas coletadas, foi encontrada correlação linear (Spearmann) no grupo controle - curvatura torácica e gibosidade torácica; em ambos os grupos - curvaturas torácica e lombar; e no grupo experimental - gibosidade torácica e as curvaturas lombar e sacral e, curvatura sacral e curvaturas torácica e lombar. Pôde-se concluir que a medida da gibosidade tem relações com as curvaturas no plano sagital. Por ser um método confiável, simples e acessível, pode ser reproduzido sem altos custos financeiros e sem causar prejuízo à saúde do paciente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed to obtain quantitative information about grain size and shape from fractured surfaces of ceramic materials. One elaborated a routine to split intergranular and transgranular grains facets of ceramic fracture surfaces by digital image processing. A commercial ceramic (ALCOA A-16, Al2O3-1.5% of CrO) was used to test the proposed method. Microstructural measurements of grain shape and size taken from fracture surfaces have been compared through descriptive statistics of distributions, with the corresponding measurements from polished and etched surfaces. The agreement between results, with the expected bias on grain size values from fractures, obtained for both types of surfaces allowed to infer that this new technique can be used to extract the relevant microstructural information from fractured surfaces, thus minimising the time consuming steps of sample preparation. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue, corrosion and wear resistance are important parameters in aircraft components development as landing gear. High strength/weight ratio and effective corrosion resistance make of titanium alloys an alternative choice to replace steel and aluminum alloys. However, titanium alloys have poor tribological properties, which reduce devices performance under friction. PVD coatings tribological systems has been increased due to their attractive mechanical properties as low environmental impact, low friction coefficient, low wear rate and hardness up to 2000 HV.In this study the influence of TiN deposited by PVD on the fatigue strength of Ti-6Al-4V alloy was evaluated. Comparison of fatigue strength of coated specimens and base material shows also a decrease when parts are coated. It was observed that the influence is more significant in high cycle fatigue tests. Scanning electron microscopy technique (SEM) was used to observe crack origin sites and fracture features. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)