This model connects directly the radar reflectivity data and hydrological variable runoff. The catchment is discretized in pixels (4 Km × 4 Km) with the same resolution of the CAPPI. Careful discretization is made so that every grid catchment pixel corresponds precisely to CAPPI grid cell. The basin is assumed a linear system and also time invariant. The forecast technique takes advantage of spatial and temporal resolutions obtained by the radar. The method uses only the measurements of the factor reflectivity distribution observed over the catchment area without using the reflectivity - rainfall rate transformation by the conventional Z-R relationships. The reflectivity values in each catchment pixel are translated to a gauging station by using a transfer function. This transfer function represents the travel time of the superficial water flowing through pixels in the drainage direction ending at the gauging station. The parameters used to compute the transfer function are concentration time and the physiographic catchment characteristics. -from Authors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a dynamic programming approach for semi-automated road extraction from medium-and high-resolution images. This method is a modified version of a pre-existing dynamic programming method for road extraction from low-resolution images. The basic assumption of this pre-existing method is that roads manifest as lines in low-resolution images (pixel footprint> 2 m) and as such can be modeled and extracted as linear features. On the other hand, roads manifest as ribbon features in medium- and high-resolution images (pixel footprint ≤ 2 m) and, as a result, the focus of road extraction becomes the road centerlines. The original method can not accurately extract road centerlines from medium- and high- resolution images. In view of this, we propose a modification of the merit function of the original approach, which is carried out by a constraint function embedding road edge properties. Experimental results demonstrated the modified algorithm's potential in extracting road centerlines from medium- and high-resolution images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper is proposed a methodology for semiautomatic CBERS image orientation using roads as ground control. It is based on an iterative strategy involving three steps. In the first step, an operator identifies on the image the ground control roads and supplies along them a few seed points, which could be sparsely and coarsely distributed. These seed points are used by the dynamic programming algorithm for extracting the ground control roads from the image. In the second step, it is established the correspondences between points describing the ground control roads and the corresponding ones extracted from the image. In the last step, the corresponding points are used to orient the CBERS image by using the DLT (Direct Linear Transformation). The two last steps are iterated until the convergence of the orientation process is verified. Experimental results showed that the proposed methodology was efficient with several test images. In all cases the orientation process converged. Moreover, the estimated orientation parameters allowed the registration of check roads with pixel accuracy or better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel multisampling time-domain architecture for CMOS imagers with synchronous readout and wide dynamic range is proposed. The architecture was implemented in a prototype of imager with 32x32 pixel array fabricated in AMS CMOS 0.35νm and was characterized for sensitivity and color response. The pixel is composed of an n+/psub photodiode, a comparator and a D flip-flop having 16% fill-factor and 30νmx26νm dimensions. The multisampling architecture requires only a 1 bit per pixel memory instead of 8 bits which is typical for time-domain active pixel architectures. The advantage is that the number of transistors in the pixel is low, saving area and providing higher fill-factor. The maximum frame rate is analyzed as a function of number of bits and array size. The analysis shows that it is possible to achieve high frame rates and operation in video mode with 10 bits. Also, we present analysis for the impact of comparator offset voltage in the fixed pattern noise. Copyright 2007 ACM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The weather and climate has a direct influence in agriculture, it affects all stages of farming, since soil preparation to harvest. Meteorological data derived from automatic or conventional weather stations are used to monitor these effects. These meteorological data has problems like difficulty of data access and low density of meteorological stations in Brazil. Meteorological data from atmospheric models, such as ECMWF (European Center for Medium-Range Weather Forecast) can be an alternative. Thus, the aim of this study was to compare 10-day period precipitation, maximum and minimum air temperature data from the ECMWF model with interpolated maps from 33 weather stations in Sao Paulo state between 2005 and 2010 and generate statistical maps pixel by pixel. Statistical index showed spatially satisfactory (most of the results with R 2 > 0.60, d > 0.7, RMSE < 5°C and < 50 mm; Es < 5°C and < 24 mm) in period and ECMWF model can be recommended for use in the Sao Paulo state.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an image compounding technique based on the use of different apodization functions, the evaluation of the signals phases and information from the interaction of different propagation modes of Lamb waves with defects for enhanced damage detection, resolution and contrast. A 16 elements linear array is attached to a 1 mm thickness isotropic aluminum plate with artificial defects. The array can excite the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two synthetic aperture (SA) images with uniform and Blackman apodization and one image of Coherence Factor Map (CFM) are obtained. The specific interaction between each propagation mode and the defects and the characteristics of acoustic radiation patterns due to different apodization functions result in images with different resolution and contrast. From the phase information one of the SA images is selected at each pixel to compound the final image. The SA images are multiplied by the CFM image to improve contrast and for the dispersive A0 mode it is used a technique for dispersion compensation. There is a contrast improvement of 47.5 dB, reducing the dead zone and improving resolution and damage detection. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital techniques have been developed and validated to assess semiquantitatively immunohistochemical nuclear staining. Currently visual classification is the standard for qualitative nuclear evaluation. Analysis of pixels that represents the immunohistochemical labeling can be more sensitive, reproducible and objective than visual grading. This study compared two semiquantitative techniques of digital image analysis with three techniques of visual analysis imaging to estimate the p53 nuclear immunostaining. Methods: Sixty-three sun-exposed forearm-skin biopsies were photographed and submitted to three visual analyses of images: the qualitative visual evaluation method (0 to 4 +), the percentage of labeled nuclei and HSCORE. Digital image analysis was performed using ImageJ 1.45p; the density of nuclei was scored per ephitelial area (DensNU) and the pixel density was established in marked suprabasal epithelium (DensPSB). Results: Statistical significance was found in: the agreement and correlation among the visual estimates of evaluators, correlation among the median visual score of the evaluators, the HSCORE and the percentage of marked nuclei with the DensNU and DensPSB estimates. DensNU was strongly correlated to the percentage of p53-marked nuclei in the epidermis, and DensPSB with the HSCORE. Conclusion: The parameters presented herein can be applied in routine analysis of immunohistochemical nuclear staining of epidermis. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Image acquisition systems based on multi-head arrangement of digital camerasare attractive alternatives enabling a larger imaging area when compared to a single framecamera. The calibration of this kind of system can be performed in several steps or byusing simultaneous bundle adjustment with relative orientation stability constraints. Thepaper will address the details of the steps of the proposed approach for system calibration,image rectification, registration and fusion. Experiments with terrestrial and aerial imagesacquired with two Fuji FinePix S3Pro cameras were performed. The experiments focusedon the assessment of the results of self-calibrating bundle adjustment with and withoutrelative orientation constraints and the effects to the registration and fusion when generatingvirtual images. The experiments have shown that the images can be accurately rectified andregistered with the proposed approach, achieving residuals smaller than one pixel. © 2013 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The silicon-based gate-controlled lateral bipolar junction transistor (BJT) is a controllable four-terminal photodetector with very high responsivity at low-light intensities. It is a hybrid device composed of a MOSFET, a lateral BJT, and a vertical BJT. Using sufficient gate bias to operate the MOS transistor in inversion mode, the photodetector allows for increasing the photocurrent gain by 106 at low light intensities when the base-emitter voltage is smaller than 0.4 V, and BJT is off. Two operation modes, with constant voltage bias between gate and emitter/source terminals and between gate and base/body terminals, allow for tuning the photoresponse from sublinear to slightly above linear, satisfying the application requirements for wide dynamic range, high-contrast, or linear imaging. MOSFETs from a standard 0.18-μm triple-well complementary-metal oxide semiconductor technology with a width to length ratio of 8 μm /2 μm and a total area of ∼ 500μm2 are used. When using this area, the responsivities are 16-20 kA/W. © 2001-2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, the basic concepts of radiometric, photometric and colorimetric calibration are presented, which were applied to three light-emitting diodes (LEDs) used to compose the different color sensations that the human eye perceives in the visible region of the electromagnetic spectrum. In this sense, an experimental setup comprising a LED drive circuit and a home-made integrating sphere was assembled for the initial radiometric and photometric calibration as well as to obtain a set of intensity and spectral combinations associated to different colorimetric CIE (Commission Internationale de l'Eclairage) coordinates. The reader can, therefore, understand, in a simple manner, the process of color composition inside a color monitor or display picture element (pixel ). © Sociedade Brasileira de Física.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the relationships between gross chemical composition and ultrasonographic characteristics of the ram testes. Ten testes from sexually mature Karakul rams were scanned ex situ with an 8-MHz linear-array transducer, in a transverse and longitudinal plane. All ultrasonograms were saved as digital images and subjected to computerized analyses. Crude protein content was determined by the Kjeldahl method, moisture was determined with an oven-drying method, and fat was measured by the Soxhlet extraction of dried samples. Mean pixel values (r = -0.64, P = 0.04), pixel heterogeneity (standard deviation of pixel values; r = -0.64, P = 0.04) and maximum pixel intensity (r = -0.76, P = 0.01) were all negatively correlated with parenchymal protein content. Pixel heterogeneity correlated directly with extractable lipids (r = 0.66, P = 0.02). The quantitative correlations between echotextural and biochemical parameters found in the present experiment confirm the utility of ultrasonographic imaging combined with computer-assisted image analysis for determining changes in testicular histophysiology. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several Lamb wave modes can be coupled to a particular structure, depending on its geometry and transducer used to generate the guided waves. Each Lamb mode interacts in a particular form with different types of defects, like notches, delamination, surface defects, resulting in different information which can be used to improve damage detection and characterization. An image compounding technique that uses the information obtained from different propagation modes of Lamb waves for non-destructive testing of plate-like structures is proposed. A linear array consisting of 16 piezoelectric elements is attached to a 1 mm thickness aluminum plate, coupling the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two images are obtained from amplitude and phase information: one image using the Total Focusing Method (TFM) and one phase image obtained from the Sign Coherence Factor (SCF). Each TFM image is multiplied by the SCF image of the respective mode to improve contrast and reduce side and grating lobes effects. The high dispersive characteristic of the A0 mode is compensated for adequate defect detection. The information in the SCF images is used to select one of the TFM mode images, at each pixel, to obtain the compounded image. As a result, dead zone is reduced, resolution and contrast are improved, enhancing damage detection when compared to the use of only one mode. © 2013 Elsevier Ltd.