353 resultados para obturator prostheses
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
In cases of total or partial maxillectomies, the prosthetic rehabilitation is an effective alternative to minimize the sequelae left by surgical resection. The present study reports a clinical case of a 52-year-old patient who underwent partial maxillectomy, with upper lip involvement. The oronasal communication, resultant from surgical resection, did not allow the patient to return to her normal social life. Besides, the upper lip partial resection damaged her face's aesthetics. The proposed treatment was the confection of an upper lip prosthesis retained by a palatal obturator. The prosthesis insertion restored the patient's facial aesthetics, contributing not only to function, but also to psychosocial adaptation.
Resumo:
Cancer is regarded as the abnormal cellular multiplication; it is not controlled by the organism; and its cells present a differentiated DNA. Initially, the disease does not show clinical signs, but it can be diagnosed by laboratorial examinations. When tumors are present in the maxillofacial area, they can entail the loss of these area organs, which become responsible for the carrier's social environment exclusion. This paper aimed at showing, through a literature review, the cancers that more commonly happen in the face and the possibilities of regenerating in the patient mutilated through surgical reconstruction and prostheses.
Resumo:
Objective: Surgical reconstruction and prosthetic obturation are alternatives for the treatment of cleft in the soft palate.Design: The present case reports the rehabilitation of a patient presenting cleft palate with obturator prosthesis associated with implant-supported retention system.Conclusions: The use of ball attachment system improved speech, masticatory efficiency, swallowing, and social behavior of the patient.
Resumo:
Both the cleaning and care of the prosthesis are fundamental for maintaining its quality. Therefore, the aim of this study was to show the methods of cleaning and care the patient needs to take as regards the prosthesis and adjacent tissue, starting with correct instruction and training by the professional. It has been verified that among the materials for fabricating maxillofacial prostheses, silicone was considered the major retainer of microorganisms on its surface. Therefore, for cleaning prostheses, the use of water and neutral soap, as well as chlorhexidine, is recommended. As regards care of the adjacent tissues, it is recommended to remove the prosthesis before going to sleep, in addition to washing the prosthesis receptor tissues with water and neutral soap or with a mixture of hydrogen peroxide and water. Whereas for the mucosal surfaces of the ophthalmic cavity, cleaning with filtered and boiled water or physiological solution at least 3 times a day is recommended.
Resumo:
Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.
Resumo:
The health of a peri-implant tissue is a critical factor for the long-term success of treatment with extraoral implants. However, infection and inflammation may occur and lead to implant loss and prostheses failure. Therefore, some postsurgical care as hygiene with soap and water, soft toothbrush, and Superfloss type dental floss and medication with anti-inflammatory and antibiotic are suggested to avoid complications. In addition, a thin and smooth layer of subcutaneous tissue in the peri-implant area should be preserved during implant insertion to favor the assistance recommended in this phase.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: Transitional implants are indicated for cases in which immediate loading is counter-indicated because a healing period is necessary for osseointegration of the definitive implants. These provisional implants were developed to support an implant-supported fixed prosthesis or overdenture to provide retention, stability, and support. The aim of this article was to conduct a literature review on transitional implants to highlight the characteristics of the transitional implants and their advantages, indications, and contraindications, including the level of osseointegration of such implants according to the functional period. Method and Materials: The present literature review was based on the OldMedline and Medline databases from 1999 to 2010 using the key words "transitional implants" and "temporary implants." Fourteen articles were found: 11 clinical studies or techniques and three histologic and histomorphometric studies. Results: The transitional immediate prostheses were worn by completely and partially edentulous patients. Advantages of transitional implants include complete denture retention, stability, and support; maintenance of chewing, phonetics, and patient comfort; protection of bone grafts; vertical stop during healing period; easy and fast surgical and prosthetic procedures; lower cost in comparison to the definitive implant; and reestablishment of esthetics. The success of transitional implants as conservative treatment for conventional immediate loading is a reality if correctly indicated. Conclusion: Transitional implants are a provisional treatment alternative for completely and partially edentulous patients. However, additional studies are required to evaluate the level of remodeling and repair of the transitional implants under loading. (Quintessence Int 2011; 42: 19-24)
Resumo:
The authors describe a literature revision on assessing stresses in buccomaxillary prostheses photoelasticity, finite element technique, and extensometry. They describe the techniques and the importance for use of each method in buccomaxillary prostheses with implants and the need of accomplishing more studies in this scarce literary area.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
During the process of facial rehabilitation, the mobility of ocular prostheses must be considered. Whereas some factors depend exclusively on the dentist, such as molding techniques and selection of material for denture construction, regarding ocular rehabilitation, factors, such as type of surgery, whether to adopt implants, and the use of lubricants, deserve special attention owing to their integration and their association with other factors pertaining exclusively to the patient. To establish harmony, and with the intention of aiding the dentist, after a discerning evaluation, the authors of this study report the factors that provide greater or less mobility to ocular prostheses and conceal the prosthesis in a more natural way, thereby contributing toward achieving a favorable aesthetic result in rehabilitations.
Resumo:
The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implant-retention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 mu m, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P < 0.05). All groups exhibited significant decrease (P < 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P < 0.05), but there was no statistically significant difference between Groups B and D (P > 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this Study was to evaluate Soft tissue response to rnaxillo-mandibular counter-clockwise rotation, with TMJ reconstruction and mandibular advancement using TMJ Concepts (R) total joint prostheses, and maxillary osteotomies in 44 females. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one Surgeon (Wolford). Eighteen patients had genioplasties with either porous block hydroxyapatite or hard tissue replacement implants (Group 2) 26 had no genioplasty (Group 1). Surgically, the maxilla moved forward and upward by counter-clockwise maxillo-mandibular rotation with greater horizontal movement in Group 2. Vertically, both groups showed diversity of maxillo-mandibular mean movement. Group I showed a consistent 1:0.97 ratio of hard to soft tissue advancement at pogonion; Group 2 results were less consistent, with ratios between 1:0.84 and 1:1.02. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement in both groups, than observed in hard tissue. Counter-clockwise rotation of the maxillo-mandibular complex using TMJ Concepts total joint prostheses resulted in similar soft tissue response as previously reported for traditional maxillo-mandibular advancement without counter-clockwise rotation of the occlusal plane. The association of chin implants, in the present sample, showed higher variability of soft tissue response.