26 resultados para noise level
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Noise mapping has been used as an instrument for assessment of environmental noise, helping to support decision making on urban planning. In Brazil, urban noise is not yet recognized as a major environmental problem by the government. Besides, cities that have databases to drive acoustic simulations, making use of advanced noise mapping systems, are rare. This study sought an alternative method of noise mapping through the use of geoprocessing, which is feasible for the Brazilian reality and for other developing countries. The area chosen for the study was the central zone of the city of Sorocaba, located in So Paulo State, Brazil. The proposed method was effective in the spatial evaluation of equivalent sound pressure level. The results showed an urban area with high noise levels that exceed the legal standard, posing a threat to the welfare of the population.
Resumo:
Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.
Resumo:
Background: Noise is the most common agent of occupational exposure. It may induce both auditory and extraauditory dysfunction and increase the risk of work accidents. The purpose of this study was to estimate the fraction of accidents attributable to noise occupational exposure in a mid-size city located in southeastern Brazil. Materials and Methods: In this population case-control study, which included 108 cases and 324 controls, the incidence rate ratio of work accidents controlled for several covariables was obtained by classifying occupational noise exposure into three levels, as well as determining the prevalence in each level. Results: Based on these data, the attributable fraction was estimated as 0.6391 (95 CI = 0.2341-0.3676), i.e., 63 of the work accidents that took place in the study site were statistically associated with occupational noise exposure. Discussion: The causes of this association as well as its implications in the prevention of work accidents are discussed.
Resumo:
Noise is the most frequent type of occupational exposure and can lead to both auditory and extra-auditory dysfunction as well as increasing the risk of work accidents. The purpose of this study was to estimate the attributable fraction of work accidents related to occupational noise exposure in a medium-sized city in Southeast Brazil. In this hospital-based case-control study, including 600 cases and 822 controls, the odds ratio of work accidents (controlled for several covariables) was obtained classifying occupational noise exposure into four levels and determining the prevalence at each level. Based on these data, the calculated attributable fraction was 0.3041 (95%CI: 0.2341-0.3676), i.e., 30% of work accidents in the study area were statistically associated with occupational noise exposure. The authors discuss the causes of this association and the implications for the prevention of work accidents.
Resumo:
An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.
Resumo:
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Aim: To evaluate the sound pressure level to which preschool students are exposed. Method: This was a prospective, quantitative, nonexperimental, and descriptive study. To achieve the aim of the study we used an audio dosimeter. The sound pressure level (SPL) measurements were obtained for 2 age based classrooms. Preschool I and II. The measurements were obtained over 4 days in 8-hour sessions, totaling 1920 minutes. Results: Compared with established standards, the SPL measured ranged from 40.6 dB (A) to 105.8 dB (A). The frequency spectrum of the SPL was concentrated in the frequency range between 500 Hz and 4000 Hz. The older children produced higher SPLs than the younger ones, and the levels varied according to the activity performed. Painting and writing were the quietest activities, while free activities period and games were the noisiest. Conclusion: The SPLs measured at the preschool were higher and exceeded the maximum permitted level according to the reference standards. Therefore, the implementation of actions that aim to minimize the negative impact of noise in this environment is essential.
Resumo:
Introduction: The biological processes involved in noise-induced hearing loss (NIHL) are still unclear. The involvement of inflammation in this condition has been suggested.Objective: To investigate the association between interleukin - 6 (IL-6) polymorphism and susceptibility to NIHL.Methods: This was a cross-sectional study with a sample of 191 independent elderly individuals aged >60 years of age. Information on exposure to occupational noise was obtained by interviews. Audiological evaluation was performed using pure tone audiometry and genotyped through PCR by restriction fragment length polymorphism - PCR-RFLP. Data were analyzed using the chi-square test and the odds ratio (OR), with the significance level set at 5%.Results: Among elderly with hearing loss (78.0%), 18.8% had a history of exposure to occupational noise. There was a statistically significant association between the genotype frequencies of the IL-6 - 174 and NIHL. The elderly with the CC genotype were less likely to have hearing loss due to occupational noise exposure when compared to those carrying the GG genotype (OR = 0.0124; 95% CI 0.0023-0.0671; p<0.001).Conclusion: This study suggests there is an association of polymorphisms in the IL-6 gene at position - G174C with susceptibility to noise-induced hearing loss. (C) 2014 Associacao Brasileira de Otorrinolaringologia e Cirurgia Cervico-Facial. Published by Elsevier Editora Ltda. All rights reserved.