26 resultados para model of criteria systems
Resumo:
When an area to be irrigated has a high slope gradient in the manifold line direction, an option is to use a tapered pipeline to economize on pipe costs and to keep pressure head variations within desired limits. The objective of this paper is to develop a linear optimization model to design a microirrigation system with tapered, downhill manifold lines, minimizing the equivalent annual cost of the hydraulic network and the annual pumping cost, and maximizing the emission uniformity previously established to the subunit. The input data are irrigation system layout, cost of all hydraulic network components, and electricity price. The output data are equivalent annual cost, pipeline diameter in each line of the system, pressure head in each node, and total operating pressure head. To illustrate its capability, the model is applied in a citrus orchard in Sao, Paulo State, Brazil, considering slopes of 3, 6, and 9%. The model proved to be efficient in the design of the irrigation system in terms of the emission uniformity desired.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Natural scales determine the physics of quantum few-body systems with short-range interactions. Thus, the scaling limit is found when the ratio between the scattering length and the interaction range tends to infinity, while the ratio between the physical scales are kept fixed. From the formal point of view, the relation of the scaling limit and the renormalization aspects of a few-body model with a zero-range interaction, through the derivation of subtracted three-body T-matrix equations that are renormalization-group invariant.
Resumo:
The aim of this paper is to study the cropping system as complex one, applying methods from theory of dynamic systems and from the control theory to the mathematical modeling of the biological pest control. The complex system can be described by different mathematical models. Based on three models of the pest control, the various scenarios have been simulated in order to obtain the pest control strategy only through natural enemies' introduction. © 2008 World Scientific Publishing Company.
Resumo:
This clinical study assessed the performance of posterior composite resins applied with the Adper™ Single Bond Plus (SB) and Adper ™ Scotchbond SE (SE) adhesive systems and Filtek ™ Supreme Plus composite resin, using modified US Public Health Service criteria. A total of 97 restorations were placed in posterior teeth by two calibrated operators. Application of the materials followed manufacturers' instructions. The restorations were evaluated by two examiners at baseline and after one year. Statistical analyses were conducted using the proportion test at a significance level of 5% (p<0.05). All the restorations evaluated (ie, 100%) received an alpha rating for the criteria of marginal discoloration and marginal integrity at baseline. At one year, for marginal discoloration, 64.6% of SB and 61.2% of SE received an alpha rating. For marginal integrity, 72.9% of SB and 77.6% of SE received an alpha rating. The other restorations received bravo ratings for both criteria. None of the teeth that received the restorative systems presented caries lesions around the restorations. A total of eight teeth presented postoperative sensitivity one week after baseline, five with SB and three with SE; the symptom had disappeared one year later. One year later, composite resin restorations using either adhesive system showed satisfactory clinical performance.
Resumo:
This paper presents an efficient tabu search algorithm (TSA) to solve the problem of feeder reconfiguration of distribution systems. The main characteristics that make the proposed TSA particularly efficient are a) the way in which the neighborhood of the current solution was defined; b) the way in which the objective function value was estimated; and c) the reduction of the neighborhood using heuristic criteria. Four electrical systems, described in detail in the specialized literature, were used to test the proposed TSA. The result demonstrate that it is computationally very fast and finds the best solutions known in the specialized literature. © 2012 IEEE.
Resumo:
In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.
Resumo:
This paper presents a methodology for modeling high intensity discharge lamps based on artificial neural networks. The methodology provides a model which is able to represent the device operating in the frequency of distribution systems, facing events related to power quality. With the aid of a data acquisition system to monitor the laboratory experiment, and using $$\text{ MATLAB }^{\textregistered }$$ software, data was obtained for the training of two neural networks. These neural networks, working together, were able to represent with high fidelity the behavior of a discharge lamp. The excellent performance obtained by these models allowed the simulation of a group of lamps in a distribution system with shorter simulation time when compared to mathematical models. This fact justified the application of this family of loads in electric power systems. The representation of the device facing power quality disturbances also proved to be a useful tool for more complex studies in distribution systems. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Quando a área a ser irrigada apresenta um elevado gradiente de declive na direção das linhas de derivação, uma opção de dimensionamento é o uso de tubulações com vários diâmetros para economizar no custo e também para manter a variação de pressão dentro dos limites desejados. O objetivo deste trabalho foi desenvolver um modelo de programação linear para dimensionar sistemas de irrigação por microaspersão com linhas de derivação com mais de um diâmetro e operando em declive, visando a minimização do custo anualizado da rede hidráulica e do custo anual com energia elétrica, além de assegurar que a máxima variação de carga hidráulica na linha será respeitada. Os dados de entrada são: configuração da rede hidráulica do sistema de irrigação, custo de todos os componentes da rede hidráulica e custo da energia. Os dados de saída são: custo anual total, diâmetro da tubulação em cada linha do sistema, carga hidráulica em cada ponto de derivação e altura manométrica total. Para ilustrar a potencialidade do modelo desenvolvido, ele foi aplicado em um pomar de citros no Estado de São Paulo, Brasil. O modelo demonstrou ser eficiente no dimensionamento do sistema de irrigação quanto à obtenção da uniformidade de emissão desejada. O custo anual com bombeamento deve ser considerado no dimensionamento de sistemas de irrigação por microaspersão porque ele gera menores valores de custo anual total quando comparado com a mesma alternativa que não considera aquele custo.
Resumo:
Objective: Criteria for metabolic syndrome (MS) differ particularly regarding the definition of central obesity and consequently, there could be differences in the assessment of cardiovascular risk. We estimated the prevalence of metabolic syndrome, compared the agreement of the World Health Organization (WHO) criteria with the standard and a modified National Cholesterol Education Program (NCEP) criterion and investigated whether additional factors were associated with the diagnosis of the syndrome in a Japanese descendant population.Methods: In this cross-sectional, population-based survey, 1166 Japanese-Brazilians (533 men, 633 women) aged 57.4 +/- 12.4 years with mean body mass index (BMI) and waist of 25.2 +/- 4.0 kg/m(2) and 84.5 +/- 10.6 cm, respectively, were included. McNemar and kappa statistics were used to assess the concordance between WHO criteria with the standard and a modified NCEP criteria (waist of 90 and 80 cm, for men and women, respectively). in logistic regression analysis, a number of metabolic variables and albumin-to-creatinine ratio were included to test independent associations with metabolic syndrome defined by the modified NCEP criteria.Results: According to WHO, 55.4% (95% Cl 52.5-58.2%) of the subjects had MS and to NCEP 47.4% (95% Cl 44.6-50.0%). WHO criterion detected 48.3% of central obese subjects while NCEP only 14.0%. Kappa statistics showed a good strength of agreement (k = 0.67, p < 0.01) between WHO and NCEP standard definitions of MS. Using the modified NCEP criterion for Asians, more subjects with metabolic syndrome were identified (58%) and agreement with WHO was improved (k = 0.72, p < 0.001). However, similar Framingham risk scores were attributed to the subsets of subjects classified by any of the three criteria. Areas under the receiver operating characteristic curves, obtained for the modified waist values to diagnose metabolic syndrome according to WHO, were > 0.80 and corresponded, respectively, to sensitivity and specificity of 63 and 83% for men and 77 and 72% for women. In final logistic regression model, age, male sex, BMI and homeostasis model assessment-insulin resistance but not with albumin-to-creatinine ratio (ACR) were independently associated with the syndrome.Conclusions: High prevalence of MS, independent of the criterion considered, was found in this Japanese-Brazilian population. The replacement of waist cutoff by those proposed by WHO for Asians lead to this diagnosis in a higher number of subjects with elevated cardiovascular risk. Our data did not support that ACR should be included in the classical definition of MS in Japanese descendants as previously suggested by WHO.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)