59 resultados para military forces
Resumo:
Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)
Resumo:
This work seeks to contribute to a better understanding of the Abdication, analyzing how and why sections of the army joined the liberal groups against the emperor, focusing on the period that immediately preceded this event. The argument is that the alliance between sections of the army and the liberal groups in 1831 was possible because the expansion of the "public space" in the city of Rio de Janeiro, a process in which newspapers such as "O Republico" played a key role as they became a privileged locus for political disputes. The article shows that that newspaper helped to build a political identity based on the defense of Brazilian interests against Portuguese despotism, giving momentum to internal conflicts around this subject that were already taking place among sections of the army and hence triggering the process that would lead to the Abdication.
Resumo:
In certain mild extensions of the standard model, spin-independent long range forces can arise by exchange of two very light pseudoscalar spin-0 bosons. In particular, we have in mind models in which these bosons do not have direct tree level couplings to ordinary fermions. Using the dispersion theoretical method, we find a 1/r3 behavior of the potential for the exchange of very light pseudoscalars and a 1/r7 dependence if the pseudoscalars are true massless Goldstone bosons. ©1999 The American Physical Society.
Resumo:
Neutrinos mediate long range forces among macroscopic bodies in a vacuum. When the bodies are placed in the neutrino cosmic background, these forces are modified. Indeed, at distances long compared to the scale T -1, the relic neutrinos completely screen off the two-neutrino exchange force, whereas for small distances the interaction remains unaffected. ©2000 The American Physical Society.
Resumo:
It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.
Resumo:
Electromyographic activity of the trapezius muscle and serratus anterior muscle was analysed in 4 different modalities of military press exercises, each of them with 2 grips: open and middle. It was analyzed 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The TS and SI muscles acted with high and very high activity in all the modalities of military press exercises. Statistically, they did not show significative difference in the performance of the exercises with open and middle grip, justifying the inclusion of this group of exercises with both grips for the physical conditioning programmes.
Resumo:
Electromyographic activity of the trapezius muscle and serratus anterior muscle was analysed in 24 male volunteers using a 2-channel TECA TE 4 electromyograp, during the execution of four different modalities of military press exercises with middle grip. The trapezius acted preferentially in the modalities standing press behind neck; and sitting forward and press behind neck, while SI did not show any significative difference among the modalities. The high levels of action potentials with which TS and SI acted justify the inclusion of these exercises in physical programmes.
Resumo:
During gray cast iron cutting, the great rate of mechanical energy from cutting forces is converted into heat. Considerable heat is generated, principally in three areas: the shear zone, rake face and at the clearance side of the cutting edge. Excessive heat will cause undesirable high temperature in the tool which leads to softening of the tool and its accelerated wear and breakage. Nowadays the advanced ceramics are widely used in cutting tools. In this paper a composition special of Si3N4 was sintering, characterized, cut and ground to make SNGN120408 and applyed in machining gray cast iron with hardness equal 205 HB in dry cutting conditions by using digital controlled computer lathe. The tool performance was analysed in function of cutting forces, flank wear, temperature and roughness. Therefore metal removing process is carried out for three different cutting speeds (300 m/min, 600 m/min, and 800 m/min), while a cutting depth of 1 mm and a feed rate of 0.33 mm/rev are kept constant. As a result of the experiments, the lowest main cutting force, which depends on cutting speed, is obtained as 264 N at 600 m/min while the highest main cutting force is recorded as 294 N at 300 m/min.
Resumo:
Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.
A máscara chinesa: Notas sobre uso das fontes produzidas pelo aparato repressivo da ditadura militar
Resumo:
The methodological aspects which the historians face when using documents produced by the Brazilian military dictatorship on the leftist movements which intended to trigger the revolutionary struggle are analyzed. Whereas the strategy of the repressive regime in producing and establishing the 'truth' is enhanced, the resistance strategies of the political forces targeted by the repressive apparatus are investigated. The documents on the political organization called Marxist-Leninist Popular Movement have been employed.
Resumo:
It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.
Resumo:
With the objective to know the electromyographic activity normal parameters of the deltoid (anterior portion) and pectoralis major (clavicular portion) muscles in the different modalities of military press exercises with middle grip, we analyzed 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes. It was observed high inactivity levels for PMC in almost all the modalities and the concentration in the active cases, mainly, in the weak potential, while DA presented very high levels of much strong action potentials in all the modalities assessed.
Resumo:
The deltoid (anterior portion) and pectoralis major (clavicular portion) were evaluated in several execution ways of military press exercises with open and middle grips in order to know their behavior pattern. It was analyzed 24 male volunteers, using a 2-channel TECA TE4 electromyograph and Hewllet Packard surface electrodes. It was observed that the execution variation with open and middle grips does not present any significant difference as for the demanding level neither for the pectoralis major muscle nor the deltoid muscle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The aim of this study was to evaluate the effect of different seating forces during cementation in cement-ceramic microtensile bond strength (μTBS). Materials and methods: Forty-five blocks (5 × 5 × 4 mm3) of a glass-infiltrated alumina-based ceramic (In-Ceram Alumina) were fabricated according to the manufacturer's instructions and duplicated in resin composite. Ceramic surfaces were polished, cleaned for 10 min in an ultrasonic bath, silica coated using a laboratory type of air abrasion device, and silanized. Each treated ceramic block was then randomly assigned to five groups (n = 9) and cemented to a composite block under five seating forces (10 g, 50 g, 100 g, 500 g, and 750 g) using a dual-cured resin cement (Panavia F). The ceramic-cement-composite assemblies were cut under coolant water to obtain bar specimens (1 mm × 0. 8 mm2). The μTBS tests were performed in a universal testing machine (1 mm/min). The mean bond strengths values were statistically analyzed using one-way ANOVA (α ≤ 0. 05). Results: Different seating forces resulted in no significant difference in the μTBS results ranging between 13. 1 ± 4. 7 and 18. 8 ± 2. 1 MPa (p = 0. 13) and no significant differences among cement thickness. Conclusions: Excessive seating forces during cementation seem not to affect the μTBS results. Clinical relevance: Excessive forces during the seating of single all-ceramic restorations cementation seem to display the same tensile bond strength to the resin cement. © 2012 Springer-Verlag.